Adam Knight

Dr. Adam Knight

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Physical Therapy in Sport
Verified
Journal Article
Closed access
JSJeffrey D. Simpson
Jeffrey D. Simpson
ESEthan Stewart
Ethan Stewart
DMDavid M. Macias
David M. Macias
HCHarish Chander
Harish Chander
AKAdam Knight
Adam Knight

1 March 2019 in The Foot
Verified
Journal Article
Closed access
Sachini Kodithuwakku ArachchigeSachini Kodithuwakku Arachchige
Sachini Kodithuwakku Arachchige
HCHarish Chander
Harish Chander
AKAdam Knight
Adam Knight

Harish ChanderHarish Chander
Harish Chander
Reuben BurchReuben Burch
Reuben Burch
PTPurva Talegaonkar
Purva Talegaonkar
DSDavid Saucier
David Saucier
Anthony LuczakAnthony Luczak
Anthony Luczak
RPRaj Prabhu
Raj Prabhu
Wearable sensors are beneficial for continuous health monitoring, movement analysis, rehabilitation, evaluation of human performance, and for fall detection. Wearable stretch sensors are increasingly being used for human movement monitoring. Additionally, falls are one of the leading causes of both fatal and nonfatal injuries in the workplace. The use of wearable technology in the workplace could be a successful solution for human movement monitoring and fall detection, especially for high fall-risk occupations. This paper provides an in-depth review of different wearable stretch sensors and summarizes the need for wearable technology in the field of ergonomics and the current wearable devices used for fall detection. Additionally, the paper proposes the use of soft-robotic-stretch (SRS) sensors for human movement monitoring and fall detection. This paper also recapitulates the findings of a series of five published manuscripts from ongoing research that are published as Parts I to V of “Closing the Wearable Gap” journal articles that discuss the design and development of a foot and ankle wearable device using SRS sensors that can be used for fall detection. The use of SRS sensors in fall detection, its current limitations, and challenges for adoption in human factors and ergonomics are also discussed.

1 April 2019 in Human Movement Science
Verified
Journal Article
Closed access
JSJeffrey D. Simpson
Jeffrey D. Simpson
ESEthan M. Stewart
Ethan M. Stewart
ATAlana J. Turner
Alana J. Turner
DMDavid M. Macias
David M. Macias
SWSamuel J. Wilson
Samuel J. Wilson
AKAdam Knight
Adam Knight

1 November 2022 in Virtual Worlds
Verified
Journal Article
Open access
PDF file
NCNathan O. Conner
Nathan O. Conner
Hannah FreemanHannah Freeman
Hannah Freeman
JJJ. Adam Jones
J. Adam Jones
Anthony LuczakAnthony Luczak
Anthony Luczak
Daniel CarruthDaniel Carruth
Daniel Carruth
Harish ChanderHarish Chander
Harish Chander
The utilization of commercially available virtual reality (VR) environments has increased over the last decade. Motion sickness that is commonly reported while using VR devices is still prevalent and reported at a higher than acceptable rate. The virtual reality induced symptoms and effects (VRISE) are considered the largest barrier to widespread usage. Current measurement methods have uniform use across studies but are subjective and are not designed for VR. VRISE and other motion sickness symptom profiles are similar but not exactly the same. Common objective physiological and biomechanical as well as subjective perception measures correlated with VRISE should be used instead. Many physiological biomechanical and subjective changes evoked by VRISE have been identified. There is a great difficulty in claiming that these changes are directly caused by VRISE due to numerous other factors that are known to alter these variables resting states. Several theories exist regarding the causation of VRISE. Among these is the sensory conflict theory resulting from differences in expected and actual sensory input. Reducing these conflicts has been shown to decrease VRISE. User characteristics contributing to VRISE severity have shown inconsistent results. Guidelines of field of view (FOV), resolution, and frame rate have been developed to prevent VRISE. Motion-to-photons latency movement also contributes to these symptoms and effects. Intensity of content is positively correlated to VRISE, as is the speed of navigation and oscillatory displays. Duration of immersion shows greater VRISE, though adaptation has been shown to occur from multiple immersions. The duration of post immersion VRISE is related to user history of motion sickness and speed of onset. Cognitive changes from VRISE include decreased reaction time and eye hand coordination. Methods to lower VRISE have shown some success. Postural control presents a potential objective variable for predicting and monitoring VRISE intensity. Further research is needed to lower the rate of VRISE symptom occurrence as a limitation of use.

1 July 2018 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
HWHunter S. Waldman
Hunter S. Waldman
SBSteven A. Basham
Steven A. Basham
FPFfi G. Price
Ffi G. Price
JSJohnEric Wm. Smith
JohnEric Wm. Smith
HCHarish Chander
Harish Chander
MMMatthew J. McAllister
Matthew J. McAllister
This study examined the effects of a dl-β-hydroxybutyrate (βHB) containing beverage on cognitive and performance measures during a bout of repeated Wingates. Fifteen healthy, college-aged males (mean ± SD; age: 23.1 ± 2.4 years, height: 165.4 ± 2.0 cm, mass: 81.4 ± 9.2 kg) volunteered for the present study. Trial 1 consisted of baseline measures and familiarization for the protocol. During trials 2 and 3, subjects reported to the laboratory, after a 10-h fast, and ingested 11.38 g of βHB or a placebo (PLA) beverage 30 min before exercise. Participants then completed a cognitive challenge (CC), consisting of a 5-min FitLight response task while cycling. At the cessation of the test, participants then completed four 15-s repeated Wingates with 4 min of rest between, followed by another 5-min CC response task. Blood ketones, glucose, and lactate were measured pre-CC and post-Wingates. βHB levels were significantly higher compared with PLA (0.53 vs. 0.21 mmol/L), respectively. A significant order effect was observed across trials 2 and 3 for total FitLight misses and hits, regardless of treatment. Further, there were no significant differences among Wingate power output between treatments, although fatigue index was higher in the βHB group compared with PLA (32.3 vs. 29.4 W/s), respectively. In conclusion, βHB did not improve high-intensity cycling or cognitive performance measures; however, these findings might be partially explained by the absolute dosing protocol used for βHB in the present study as opposed to a relative (g/kg) dosing protocol used in previous research.