Edgar Jiménez-Díaz

Edgar Jiménez-Díaz

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
AMAlda Malagón-Escandón
Alda Malagón-Escandón
MHMathieu Hautefeuille
Mathieu Hautefeuille
EJEdgar Jiménez-Díaz
Edgar Jiménez-Díaz
JAJesús Ángel Arenas Alatorre
Jesús Ángel Arenas Alatorre
JSJose M Saniger
Jose M Saniger
ACAndrés Eliú Castell-Rodríguez
Andrés Eliú Castell-Rodríguez
The use of three-dimensional porous scaffolds derived from decellularized extracellular matrix (ECM) is increasing for functional repair and regeneration of injured bone tissue. Because these scaffolds retain their native structures and bioactive molecules, in addition to showing low immunogenicity and good biodegradability, they can promote tissue repair and regeneration. Nonetheless, imitating these features in synthetic materials represents a challenging task. Furthermore, due to the complexity of bone tissue, different processes are necessary to maintain these characteristics. We present a novel approach using decellularized ECM material derived from bovine cancellous bone by demineralization, decellularization, and hydrolysis of collagen to obtain a three-dimensional porous scaffold. This study demonstrates that the three-dimensional porous scaffold obtained from bovine bone retained its osteoconductive and osteoinductive properties and presented osteogenic potential when seeded with human Wharton’s jelly mesenchymal stromal cells (hWJ-MSCs). Based on its characteristics, the scaffold described in this work potentially represents a therapeutic strategy for bone repair.

30 August 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
EJEdgar Jiménez-Díaz
Edgar Jiménez-Díaz
MCMariel Cano-Jorge
Mariel Cano-Jorge
DZDiego Zamarrón-Hernández
Diego Zamarrón-Hernández
LCLucia Cabriales
Lucia Cabriales
FLFrancisco Paez Larios
Francisco Paez Larios
MHMathieu Hautefeuille
Mathieu Hautefeuille
Microfluidics has become a very promising technology in recent years, due to its great potential to revolutionize life-science solutions. Generic microfabrication processes have been progressively made available to academic laboratories thanks to cost-effective soft-lithography techniques and enabled important progress in applications like lab-on-chip platforms using rapid- prototyping. However, micron-sized features are required in most designs, especially in biomimetic cell culture platforms, imposing elevated costs of production associated with lithography and limiting the use of such devices. In most cases, however, only a small portion of the structures require high-resolution and cost may be decreased. In this work, we present a replica-molding method separating the fabrication steps of low (macro) and high (micro) resolutions and then merging the two scales in a single chip. The method consists of fabricating the largest possible area in inexpensive macromolds using simple techniques such as plastics micromilling, laser microfabrication, or even by shrinking printed polystyrene sheets. The microfeatures were made on a separated mold or onto existing macromolds using photolithography or 2-photon lithography. By limiting the expensive area to the essential, the time and cost of fabrication can be reduced. Polydimethylsiloxane (PDMS) microfluidic chips were successfully fabricated from the constructed molds and tested to validate our micro–macro method.

16 April 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
ARAarón Cruz Ramírez
Aarón Cruz Ramírez
RSRaúl Sánchez-Olvera
Raúl Sánchez-Olvera
DZDiego Zamarrón-Hernández
Diego Zamarrón-Hernández
MHMathieu Hautefeuille
Mathieu Hautefeuille
LCLucia Cabriales
Lucia Cabriales
GVGenaro Vázquez-Victorio
Genaro Vázquez-Victorio
The development of organ-on-chip and biological scaffolds is currently requiring simpler methods for microstructure biocompatible materials in three dimensions, to fabricate structural and functional elements in biomaterials, or modify the physicochemical properties of desired substrates. Aiming at addressing this need, a low-power CD-DVD-Blu-ray laser pickup head was mounted on a programmable three-axis micro-displacement system in order to modify the surface of polymeric materials in a local fashion. Thanks to a specially-designed method using a strongly absorbing additive coating the materials of interest, it has been possible to establish and precisely control processes useful in microtechnology for biomedical applications. The system was upgraded with Blu-ray laser for additive manufacturing and ablation on a single platform. In this work, we present the application of these fabrication techniques to the development of biomimetic cellular culture platforms thanks to the simple integration of several features typically achieved with traditional, less cost-effective microtechnology methods in one step or through replica-molding. Our straightforward approach indeed enables great control of local laser microablation or polymerization for true on-demand biomimetic micropatterned designs in transparent polymers and hydrogels and is allowing integration of microfluidics, microelectronics, surface microstructuring, and transfer of superficial protein micropatterns on a variety of biocompatible materials.

23 March 2018 in Preprints.org
Verified
Preprint
Open access
ACAarón Cruz-Ramírez
Aarón Cruz-Ramírez
RSRaúl Sánchez-Olvera
Raúl Sánchez-Olvera
DZDiego Zamarrón-Hernández
Diego Zamarrón-Hernández
MHMathieu Hautefeuille
Mathieu Hautefeuille
LCLucia Cabriales
Lucia Cabriales
GVGenaro Vázquez-Victorio
Genaro Vázquez-Victorio
The development of organ-on-chip and biological scaffolds is currently requiring simpler methods to microstructure biocompatible materials in three dimensions, fabricate structural and functional elements in biomaterials or modify the physicochemical properties of desired substrates. Aiming at addressing this need, a low-power CD-DVD-Blu-ray laser pickup head was mounted on a programmable three-axis micro-displacement system in order to modify the surface of polymeric materials in a local fashion. Thanks to a specially-designed method using a strongly absorbing additive coating the materials of interest, it has been possible to establish and precisely control processes useful in microtechnology for biomedical applications. The system was upgraded with blu-ray laser for additive manufacturing and ablation on a single platform. In this work, we present the application of these fabrication techniques to the development of biomimetic cellular culture platforms thanks to the simple integration of several features typically achieved with traditional, less cost-effective microtechnology methods in one step or through replica-molding. Our straightforward approach indeed enables great control of local laser microablation or polymerization for true on-demand biomimetic micropatterned designs in transparent polymers and hydrogels and is allowing integration of microfluidics, microelectronics, surface microstructuring and transfer of superficial protein micropatterns on a variety of biocompatible materials.

11 July 2025 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Open access
EJEdgar Jiménez-Díaz
Edgar Jiménez-Díaz
CPCindy Viridiana Peto-Gutiérrez
Cindy Viridiana Peto-Gutiérrez
MHMathieu Hautefeuille
Mathieu Hautefeuille
TFTatiana Fiordelisio
Tatiana Fiordelisio
Two-photon polymerization (2PP) enables the fabrication of complex three dimensional microstructures with submicron precision, making it a powerful tool for mechanobiology studies. In this work we present a highly reproducible 2PP- based method to fabricate high aspect ratio micropillars, achieving aspect ratios up to 1:20 while maintaining structural stability. These micropillars were employed to quantify the contractile forces exerted by pituitary pericytes in response to ATP stimulation, providing novel insights into their mechanobiology. Using a custom-designed perfusion chamber and confocal microscopy, we measured both intracellular calcium dynamics and pillar displacements, revealing that pericytes generate contractile forces primarily through their peripheral extensions, with forces reaching up to 77.81 ± 26.85 nN post-stimulation. The study also introduces a novel protocol for isolating and culturing primary pituitary pericytes, confirming their identity through immunostaining for PDGFR-β and NG2 markers. Our results demonstrate that pericytes exhibit a delayed but sustained contractile response to ATP, correlating with intracellular calcium signaling. This work advances our understanding of pericyte mechanotransduction and their role in microvascular regulation, offering a robust platform for future mechanobiology research.

15 June 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
TFTatiana Fiordelisio
Tatiana Fiordelisio
Ivette Buendia-RoldanIvette Buendia-Roldan
Ivette Buendia-Roldan
MHMathieu Hautefeuille
Mathieu Hautefeuille
Diana Del-RioDiana Del-Rio
Diana Del-Rio
Diana Ríos-LópezDiana Ríos-López
Diana Ríos-López
MSMoises Selman
Moises Selman
In spite of a current increasing trend in the development of miniaturized, standalone point-of-care (PoC) biosensing platforms in the literature, the actual implementation of such systems in the field is far from being a reality although deeply needed. In the particular case of the population screenings for local or regional diseases related to specific pathogens, the diagnosis of the presence of specific antibodies could drastically modify therapies and even the organization of public policies. The aim of this work was to develop a fast, cost-effective detection method based on the manipulation of functionalized magnetic beads for an efficient diagnosis of hypersensitivity pneumonitis (HP), looking for the presence of anti-pigeon antigen antibodies (APAA) in a patient’s serum. We presented a Diagnostic Biosensor Method (DBM) in detail, with validation by comparison with a traditional high-throughput platform (ELISA assay). We also demonstrated that it was compatible with a microfluidic chip that could be eventually incorporated into a PoC for easy and broad deployment using portable optical detectors. After standardization of the different reaction steps, we constructed and validated a plastic chip that could easily be scaled to high-volume manufacturing in the future. The solution proved comparable to conventional ELISA assays traditionally performed by the clinicians in their laboratory and should be compatible with other antibody detection directly from patient samples.