In recent years, a large number of three-phase phase-locked loops (PLLs) have been developed. One of the most popular ones is the complex coefficient filter-based PLL (CCF-PLL), which benefits from a sequence selective filtering ability. This feature enables the CCF-PLL to selectively reject/extract disturbances before the PLL control loop while maintaining an acceptable dynamic behavior. The aim of this letter is presenting a simple yet effective approach to enhance the standard CCF-PLL performance without requiring any additional computational load.
17 December 2018 in IEEE Transactions on Smart Grid
With increased grid penetration of distributed energy resources (DERs), Volt/VAR control (VVC) is becoming increasingly complex and challenging in distribution systems. Conventional VVC approaches in distribution networks reside typically on the primary feeder. However, these approaches are ineffective for handling the voltage variability caused by DERs and load dynamics on the secondary side, termed as the grid edge. With more and more deployments of DERs at the grid edge, advanced VVC technologies through controlling DER inverters are perceived to be the key enabling technologies for distributed voltage control to meet the future smart grid requirements. Nevertheless, a great challenge is that DER inverters would fight each other when operated autonomously in participating grid voltage control using the conventional control methods. This paper proposes a novel VVC strategy based on an artificial neural network (ANN) control. The proposed approach is able to properly handle DER inverter constraints in achieving VVC objectives at the grid edge and overcomes the challenges of conventional DER inverter control techniques. The behaviors of the proposed method are evaluated via simulation and hardware experiments, which demonstrates great advantages of the ANN-based VVC for controlling DER inverters at the grid edge.
24 January 2019 in IEEE Transactions on Industrial Electronics
The introduction of virtual-synchronous machine (VSM) and generator (VSG) as well as synchronous inverter (synchronverter), in recent years, has facilitated the integration of inverter-interfaced distributed energy resources (IIDERs) into the synchronous generator (SG) dominant microgrids and power grid. In this concept, the voltage source inverter (VSI) is controlled in such a way that mimics the behavior of SG. To provide a reliable utilization of the IIDERs, a seamless transition of the VSIs between islanded and grid-connected operation modes is required. This paper integrates a novel virtual torque (VT) and virtual flux linkage (VFL)-based synchronizing technique into the synchronverter controller to provide a plug "n" play capability of the VSIs and their smooth transition between these two operation modes. Comprehensive mathematical modeling, design, and dynamic stability analysis as well as dSPACE-based real-time simulation are provided to validate the effectiveness of the proposed technique.
The common practice for controlling the stand‐alone voltage source inverters (VSIs) is to transform abc voltage and current signals to DC signals using the dq transformation, which makes it possible to control the new DC voltage and current signals just using simple proportional‐integral controllers with a zero steady‐state tracking error. However, the transformation causes coupling terms between d ‐ and q ‐axis components in both current control loops and voltage control loops, which deteriorate the dynamic and steady‐state performance of the control system. This study presents a step‐by‐step graphical analysis and design approach for a three‐phase stand‐alone VSI system in the dq reference frame, which provides a clear systematic decoupling process to design the inner‐ and outer‐loop current and voltage controllers, respectively. The closed‐loop d ‐ and q ‐axis output impedances of the stand‐alone VSI system by considering the coupling effects between axes are also formulated, modelled, and evaluated. The study investigates how the decoupling and compensating terms added in the current and voltage controllers affect the dynamic performance and output dq impedances of the VSI system. Simulation and hardware results verify the effectiveness of the graphic design and analysis strategy.
2 September 2016 in IET Renewable Power Generation
Traditionally, active and reactive power sharing between parallel inverters based on droop control method is considered as a high priority for operating an islanded microgrid. An issue in droop control of parallel inverters in the islanding mode is the voltage drop associated with reactive power sharing within a microgrid. However, maintaining microgrid voltage stability while sharing active power between parallel inverters should be the primary objective for a microgrid. This study proposes to integrate droop and direct‐current vector control (DCVC) techniques for active power sharing and bus voltage control within a microgrid. The proposed approach consists of a droop‐only controlled unit whose function is similar to a traditional slack bus generator and the rest inverters controlled by using a combined droop‐DCVC technique. The droop‐DCVC controlled units provide active power sharing among parallel inverters and at the same time maintain microgrid voltage level by injecting the needed reactive power that is determined automatically from the droop‐DCVC controllers. Parallel inverter units with loads for a microgrid in the islanding mode are simulated using Matlab/Simulink and Opal‐RT real‐time simulation system. The hardware experiment is also conducted for two parallel inverters. Results show the effectiveness and excellent performance of parallel inverters in the microgrid by combining DCVC and droop methods.