Anas Ben Achour

Mr. Anas Ben Achour

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
AAAnas Ben Achour
Anas Ben Achour
HMHeike Meißner
Heike Meißner
UTUwe Teicher
Uwe Teicher
DHDominik Haim
Dominik Haim
URUrsula Range
Ursula Range
GLGünter Lauer
Günter Lauer

1 December 2021 in Biotribology
Verified
Journal Article
Closed access
AAAnas Ben Achour
Anas Ben Achour
CPCarola Petto
Carola Petto
HMHeike Meissner
Heike Meissner
AMAnita Mostofa
Anita Mostofa
UTUwe Teicher
Uwe Teicher
GLGünter Lauer
Günter Lauer

9 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
AAAnas Ben Achour
Anas Ben Achour
CPCarola Petto
Carola Petto
HMHeike Meissner
Heike Meissner
DHDominik Hipp
Dominik Hipp
ANAndreas Nestler
Andreas Nestler
UTUwe Teicher
Uwe Teicher
Bone drill chips that are collected during implant site preparation can be reused as autologous bone-grafting material for alveolar ridge augmentation. This study characterized five market-leading implant drill sets regarding their geometric properties and ability to produce vital bone chips. The drill geometry of each tool of five commercial implant drill sets was characterized while using optical profile projector devices and SEM. Bone chips were collected during the in vitro preparation of porcine jaw bone with the various drill sets. Produced bone chip masses were measured. The bone chips were cultured in vitro and the number of outgrown cells was determined and measurand for vitality. Furthermore, the thrust force and cutting torque were recorded to examine the mechanical loads of the manual drilling process. The tool geometry and set configuration of one out of five implant drill sets appears to be superior regarding chip mass, vitality, and thrust force. It could be proven that there is a correlation between vitality and thrust force. The thrust force is influenced by the cutting behavior of the tool, which in turn depends on the geometry of the tool. The tool geometry has an influence on the vitality of the augmentation material due to this relationship.

27 January 2023 in JMIR Medical Informatics
Verified
Journal Article
Open access
KKKarol Kozak
Karol Kozak
ASAndré Seidel
André Seidel
NMNataliia Matvieieva
Nataliia Matvieieva
CNConstanze Neupetsch
Constanze Neupetsch
UTUwe Teicher
Uwe Teicher
WDWelf-Guntram Drossel
Welf-Guntram Drossel
Background: The electronic health record (EHR) targets systematized collection of patient-specific, electronically stored health data. The EHR is an evolving concept driven by ongoing developments and open or unclear legal issues concerning medical technologies, cross-domain data integration, and unclear access roles. Consequently, an interdisciplinary discourse based on representative pilot scenarios is required to connect previously unconnected domains. Objective: We address cross-domain data integration including access control using the specific example of a unique device identification (UDI)–expanded hip implant. In fact, the integration of technical focus data into the hospital information system (HIS) is considered based on surgically relevant information. Moreover, the acquisition of social focus data based on mobile health (mHealth) is addressed, covering data integration and networking with therapeutic intervention and acute diagnostics data. Methods: In addition to the additive manufacturing of a hip implant with the integration of a UDI, we built a database that combines database technology and a wrapper layer known from extract, transform, load systems and brings it into a SQL database, WEB application programming interface (API) layer (back end), interface layer (rest API), and front end. It also provides semantic integration through connection mechanisms between data elements. Results: A hip implant is approached by design, production, and verification while linking operation-relevant specifics like implant-bone fit by merging patient-specific image material (computed tomography, magnetic resonance imaging, or a biomodel) and the digital implant twin for well-founded selection pairing. This decision-facilitating linkage, which improves surgical planning, relates to patient-specific postoperative influencing factors during the healing phase. A unique product identification approach is presented, allowing a postoperative read-out with state-of-the-art hospital technology while enabling future access scenarios for patient and implant data. The latter was considered from the manufacturing perspective using the process manufacturing chain for a (patient-specific) implant to identify quality-relevant data for later access. In addition, sensor concepts were identified to use to monitor the patient-implant interaction during the healing phase using wearables, for example. A data aggregation and integration concept for heterogeneous data sources from the considered focus domains is also presented. Finally, a hierarchical data access concept is shown, protecting sensitive patient data from misuse using existing scenarios. Conclusions: Personalized medicine requires cross-domain linkage of data, which, in turn, require an appropriate data infrastructure and adequate hierarchical data access solutions in a shared and federated data space. The hip implant is used as an example for the usefulness of cross-domain data linkage since it bundles social, medical, and technical aspects of the implantation. It is necessary to open existing databases using interfaces for secure integration of data from end devices and to assure availability through suitable access models while guaranteeing long-term, independent data persistence. A suitable strategy requires the combination of technical solutions from the areas of identity and trust, federated data storage, cryptographic procedures, and software engineering as well as organizational changes.

3 May 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
UTUwe Teicher
Uwe Teicher
AAAnas Ben Achour
Anas Ben Achour
ANAndreas Nestler
Andreas Nestler
ABAlexander Brosius
Alexander Brosius
GLGünter Lauer
Günter Lauer
The machining operation drilling is part of the standard repertoire for medical applications. This machining cycle, which is usually a multi-stage process, generates the geometric element for the subsequent integration of implants, which are screwed into the bone in subsequent processes. In addition to the form, shape and position of the generated drill hole, it is also necessary to use a technology that ensures an operation with minimal damage. A surface damaged by excessive mechanical and thermal energy input shows a deterioration in the healing capacity of implants and represents a structure with complications for inflammatory reactions. The resulting loads are influenced by the material properties of the bone, the used technology and the tool properties. An important aspect of the process analysis is the fact that machining of bone is in most of the cases a manual process that depends mainly on the skills of the operator. This includes, among other things, the machining time for the production of a drill hole, since manual drilling is a force-controlled process. Experimental work was carried out on the bone of a porcine mandible in order to investigate the interrelation of the applied load during drilling. It can be shown that the load application can be subdivided according to the working feed direction. The entire drilling process thus consists of several time domains, which can be divided into the geometry-generating feed motion and a retraction movement of the tool. It has been shown that the removal of the tool from the drill hole has a significant influence on the mechanical load input. This fact is proven in detail by a new evaluation methodology. The causes of this characteristic can also be identified, as well as possible ways of reducing the load input.

15 July 2023
Verified
Book Chapter
Closed access
PDF file
UTUwe Teicher
Uwe Teicher
AAAnas Ben Achour
Anas Ben Achour
ESErik Selbmann
Erik Selbmann
ODOzan Emre Demir
Ozan Emre Demir
DADena Arabsolgar
Dena Arabsolgar
MCMarcello Colledani
Marcello Colledani