Accelerometers are commonly used in clinical and epidemiological research for more detailed measures of physical activity and to target the limitations of self‐report methods. Sensors are attached at the hip, wrist and thigh, and the acceleration data are processed and calibrated in different ways to determine activity intensity, body position and/or activity type. Simple linear modelling can be used to assess activity intensity from hip and thigh data, whilst more advanced machine‐learning modelling is to prefer for the wrist. The thigh position is most optimal to assess body position and activity type using machine‐learning modelling. Frequency filtering and measurement resolution needs to be considered for correct assessment of activity intensity. Simple physical activity measures and statistical methods are mostly used to investigate relationship with health, but do not take advantage of all information provided by accelerometers and do not consider all components of the physical activity behaviour and their interrelationships. More advanced statistical methods are suggested that analyse patterns of multiple measures of physical activity to demonstrate stronger and more specific relationships with health. However, evaluations of accelerometer methods show considerable measurement errors, especially at individual level, which interferes with their use in clinical research and practice. Therefore, better objective methods are needed with improved data processing and calibration techniques, exploring both simple linear and machine‐learning alternatives. Development and implementation of accelerometer methods into clinical research and practice requires interdisciplinary collaboration to cover all aspects contributing to useful and accurate measures of physical activity behaviours related to health.
In objective physical activity (PA) measurements, applying wider frequency filters than the most commonly used ActiGraph (AG) filter may be beneficial when processing accelerometry data. However, the vulnerability of wider filters to noise has not been investigated previously. This study explored the effect of wider frequency filters on measurements of PA, sedentary behavior (SED), and capturing of noise. Apart from the standard AG band-pass filter (0.29–1.63 Hz), modified filters with low-pass component cutoffs at 4 Hz, 10 Hz, or removed were analyzed. Calibrations against energy expenditure were performed with lab data from children and adults to generate filter-specific intensity cut-points. Free-living accelerometer data from children and adults were processed using the different filters and intensity cut-points. There was a contribution of acceleration related to PA at frequencies up to 10 Hz. The contribution was more pronounced at moderate and vigorous PA levels, although additional acceleration also occurred at SED. The classification discrepancy between AG and the wider filters was small at SED (1–2%) but very large at the highest intensities (>90%). The present study suggests an optimal low-pass frequency filter with a cutoff at 10 Hz to include all acceleration relevant to PA with minimal effect of noise.
18 May 2019 in Scandinavian Journal of Medicine & Science in Sports
ActiGraph is the most common accelerometer in physical activity research, but it has measurement errors due to restrictive frequency filtering. This study investigated biomechanically how different frequency filtering of accelerometer data affects assessment of activity intensity and age-group differences when measuring physical activity. Data from accelerometer at the hip and motion capture system was recorded during treadmill walking and running from 30 subjects in three different age groups: 10, 15, and >20 years old. Acceleration data was processed to ActiGraph counts with original band-pass filter at 1.66 Hz, to counts with wider filter at either 4 or 10 Hz, and to unfiltered acceleration according to “Euclidian norm minus one” (ENMO). Internal and external power, step frequency, and vertical displacement of center of mass (VD) were estimated from the motion capture data. Widening the frequency filter improved the relationship between higher locomotion speed and counts. It also removed age-group differences and decreased within-group variation. While ActiGraph counts were almost exclusively explained by VD, the counts from the 10 Hz filter were explained by VD and step frequency to an equal degree. In conclusion, a wider frequency filter improves assessment of physical activity intensity by more accurately capturing individual gait patterns.
Background: The objective and accurate assessment of children’s sedentary and physical behavior is important for investigating their relation to health. The purpose of this study is to validate a simple and robust method for the identification of sitting, standing, walking, running and biking performed by preschool children, children and adolescents in the age from 3 to 16 years from a single thigh-worn accelerometer. Method: A total of 96 children were included in the study and all subjects followed a structured activity protocol performed in the subject’s normal kindergarten or school environment. Thigh acceleration was measured using the Axivity AX3 (Axivity, Newcastle, UK) device. Method development and accuracy was evaluated by equally dividing the subjects into a development and test group. Results: The sensitivity and specificity for identifying sitting and standing was above 99.3% and for walking and running above 82.6% for all age groups. The sensitivity and specificity for identifying biking was above 85.8% for children and adolescents and above 64.8% for the preschool group using running bikes. Conclusion: The accurate assessment of sitting, standing, walking, running and biking from thigh acceleration and with children in the age range of 3 to 16 is valid, although not with preschool children using running bikes.
28 June 2017 in Scandinavian Journal of Medicine & Science in Sports
SenseWear Armband (SW) is a multisensor monitor to assess physical activity and energy expenditure. Its prediction algorithms have been updated periodically. The aim was to validate SW in children, adolescents, and adults. The most recent SW algorithm 5.2 (SW5.2) and the previous version 2.2 (SW2.2) were evaluated for estimation of energy expenditure during semi‐structured activities in 35 children, 31 adolescents, and 36 adults with indirect calorimetry as reference. Energy expenditure estimated from waist‐worn ActiGraph GT3X+ data (AG) was used for comparison. Improvements in measurement errors were demonstrated with SW5.2 compared to SW2.2, especially in children and for biking. The overall mean absolute percent error with SW5.2 was 24% in children, 23% in adolescents, and 20% in adults. The error was larger for sitting and standing (23%‐32%) and for basketball and biking (19%‐35%), compared to walking and running (8%‐20%). The overall mean absolute error with AG was 28% in children, 22% in adolescents, and 28% in adults. The absolute percent error for biking was 32%‐74% with AG. In general, SW and AG underestimated energy expenditure. However, both methods demonstrated a proportional bias, with increasing underestimation for increasing energy expenditure level, in addition to the large individual error. SW provides measures of energy expenditure level with similar accuracy in children, adolescents, and adults with the improvements in the updated algorithms. Although SW captures biking better than AG, these methods share remaining measurements errors requiring further improvements for accurate measures of physical activity and energy expenditure in clinical and epidemiological research.