Accelerometers are commonly used in clinical and epidemiological research for more detailed measures of physical activity and to target the limitations of self‐report methods. Sensors are attached at the hip, wrist and thigh, and the acceleration data are processed and calibrated in different ways to determine activity intensity, body position and/or activity type. Simple linear modelling can be used to assess activity intensity from hip and thigh data, whilst more advanced machine‐learning modelling is to prefer for the wrist. The thigh position is most optimal to assess body position and activity type using machine‐learning modelling. Frequency filtering and measurement resolution needs to be considered for correct assessment of activity intensity. Simple physical activity measures and statistical methods are mostly used to investigate relationship with health, but do not take advantage of all information provided by accelerometers and do not consider all components of the physical activity behaviour and their interrelationships. More advanced statistical methods are suggested that analyse patterns of multiple measures of physical activity to demonstrate stronger and more specific relationships with health. However, evaluations of accelerometer methods show considerable measurement errors, especially at individual level, which interferes with their use in clinical research and practice. Therefore, better objective methods are needed with improved data processing and calibration techniques, exploring both simple linear and machine‐learning alternatives. Development and implementation of accelerometer methods into clinical research and practice requires interdisciplinary collaboration to cover all aspects contributing to useful and accurate measures of physical activity behaviours related to health.
In objective physical activity (PA) measurements, applying wider frequency filters than the most commonly used ActiGraph (AG) filter may be beneficial when processing accelerometry data. However, the vulnerability of wider filters to noise has not been investigated previously. This study explored the effect of wider frequency filters on measurements of PA, sedentary behavior (SED), and capturing of noise. Apart from the standard AG band-pass filter (0.29–1.63 Hz), modified filters with low-pass component cutoffs at 4 Hz, 10 Hz, or removed were analyzed. Calibrations against energy expenditure were performed with lab data from children and adults to generate filter-specific intensity cut-points. Free-living accelerometer data from children and adults were processed using the different filters and intensity cut-points. There was a contribution of acceleration related to PA at frequencies up to 10 Hz. The contribution was more pronounced at moderate and vigorous PA levels, although additional acceleration also occurred at SED. The classification discrepancy between AG and the wider filters was small at SED (1–2%) but very large at the highest intensities (>90%). The present study suggests an optimal low-pass frequency filter with a cutoff at 10 Hz to include all acceleration relevant to PA with minimal effect of noise.
18 May 2019 in Scandinavian Journal of Medicine & Science in Sports
ActiGraph is the most common accelerometer in physical activity research, but it has measurement errors due to restrictive frequency filtering. This study investigated biomechanically how different frequency filtering of accelerometer data affects assessment of activity intensity and age-group differences when measuring physical activity. Data from accelerometer at the hip and motion capture system was recorded during treadmill walking and running from 30 subjects in three different age groups: 10, 15, and >20 years old. Acceleration data was processed to ActiGraph counts with original band-pass filter at 1.66 Hz, to counts with wider filter at either 4 or 10 Hz, and to unfiltered acceleration according to “Euclidian norm minus one” (ENMO). Internal and external power, step frequency, and vertical displacement of center of mass (VD) were estimated from the motion capture data. Widening the frequency filter improved the relationship between higher locomotion speed and counts. It also removed age-group differences and decreased within-group variation. While ActiGraph counts were almost exclusively explained by VD, the counts from the 10 Hz filter were explained by VD and step frequency to an equal degree. In conclusion, a wider frequency filter improves assessment of physical activity intensity by more accurately capturing individual gait patterns.
Background: Observational studies investigating the association between accelerometer-measured physical activity and health all use absolute measures of physical activity intensity. However, intervention studies suggest that the physical activity intensity required to improve health is relative to individual fitness. The aim of this study was to investigate the associations between accelerometer-measured absolute and relative physical activity intensity and cardiometabolic health, and what implications these associations may have on the interpretation of health-associated physical activity. Methods: A sample of the cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) consisting of 4,234 men and women aged 55–64 years was studied. Physical activity intensity was measured by accelerometry and expressed as absolute (e.g., metabolic equivalents of task) or relative (percentage of maximal oxygen consumption). Fitness was estimated by the submaximal Ekblom-Bak test. A composite (‘metabolic syndrome’) score combined measures of waist circumference, systolic blood pressure, high-density lipoprotein, triglycerides, and glycated hemoglobin. Associations of absolute and relative physical activity intensity with the health indicators (i.e., fitness and metabolic syndrome score) were studied by partial least squares regression. Analyses were stratified by fitness level. Results: Both absolute and relative physical activity intensity associated with the health indicators. However, the strongest associations for absolute intensity varied depending on fitness levels, whereas the associations for relative intensity were more synchronized across fitness groups. The dose–response relationship between moderate-to-vigorous intensity and the health indicators was stronger for relative than for absolute intensity. The absolute and relative moderate-to-vigorous intensity cut-offs intersected at the 5th fitness percentile, indicating that the absolute intensity cut-off is too low for 95% of individuals in this sample. While 99% of individuals fulfilled the general physical activity recommendations based on absolute intensity measures, only 21% fulfilled the recommendations based on relative intensity measures. In relation to a “sufficient” fitness level, 9% fulfilled the recommendations. Conclusions: Accelerometer-measured relative physical activity intensity represents the intensity related to health benefits regardless of fitness level. Traditional absolute moderate intensity accelerometer cut-offs are too low for most individuals and should be adapted to the fitness level in the sample studied. Absolute and relative physical activity intensity cannot be used interchangeably.
Accelerometer calibration for physical activity (PA) intensity is commonly performed using Metabolic Equivalent of Task (MET) as criterion. However, MET is not an age-equivalent measure of PA intensity, which limits the use of MET-calibrated accelerometers for age-related PA investigations. We investigated calibration using VO2net (VO2gross − VO2stand; mL⋅min−1⋅kg−1) as criterion compared to MET (VO2gross/VO2rest) and the effect on assessment of free-living PA in children, adolescents and adults. Oxygen consumption and hip/thigh accelerometer data were collected during rest, stand and treadmill walk and run. Equivalent speed (Speedeq) was used as indicator of the absolute speed (Speedabs) performed with the same effort in individuals of different body size/age. The results showed that VO2net was higher in younger age-groups for Speedabs, but was similar in the three age-groups for Speedeq. MET was lower in younger age-groups for both Speedabs and Speedeq. The same VO2net-values respective MET-values were applied to all age-groups to develop accelerometer PA intensity cut-points. Free-living moderate-and-vigorous PA was 216, 115, 74 and 71 min/d in children, adolescents, younger and older adults with VO2net-calibration, but 140, 83, 74 and 41 min/d with MET-calibration, respectively. In conclusion, VO2net calibration of accelerometers may provide age-equivalent measures of PA intensity/effort for more accurate age-related investigations of PA in epidemiological research.