Wahid Maref

Dr. Wahid Maref

Construction Engineering Department, École de Technologie Supérieure (ÉTS), University of Quebec, Montréal, QC H3C 1K3, Canada
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2019 in International Journal of Green Energy
Verified
Journal Article
Closed access
NBNaoufel Benrachi
Naoufel Benrachi
MOMohamed Ouzzane
Mohamed Ouzzane
ASArezki Smaili
Arezki Smaili
LLLouis Lamarche
Louis Lamarche
MBMessaoud Badache
Messaoud Badache
WMWahid Maref
Wahid Maref
Thermal potential for cooling and heating can be achieved by new configuration of earth–air heat exchanger (EAHE). This paper presents a numerical investigation of thermal performance of a spiral-shaped configuration of EAHE intended for the summer cooling in hot and arid regions of Algeria. A commercial finite volume software (ANSYS FLUENT) has been used to carry out the transient three-dimensional simulations and the obtained results have been validated using the experimental and numerical data obtained from the literature. The agreement between our simulation results and those from literature is very satisfactory. A parametric analysis of the new geometry of (EAHE) has been performed to investigate the effect of pitch, depth, pipe length and of the flow velocity on the outlet air temperature and the EAHE’s mean efficiency as well as its coefficient of performance (COP). It has been shown that when the pitch space varies between 0.2 and 2 m the difference of outlet air temperature increases by 6 °C. When the air velocity increases from 2 to 5 m/s the mean efficiency decreases from 60 % to 33 % and the COP of the EAHE decreases from 2.84 to 0.46.

18 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Hossein ArastehHossein Arasteh
Hossein Arasteh
WMWahid Maref
Wahid Maref
HSHamed H. Saber
Hamed H. Saber
The building envelope provides thermal comfort, an excellent visual view, and sunlight for the occupants. It consists of two parts: (i) an opaque (non-transparent) part (e.g., walls and roofs) and (ii) a transparent part (e.g., windows, curtain walls, and skylight devices). Recently, the use of fully-glazed facades, especially in large cities, has increased due to their aesthetical and structural advantages. This has led this study to review the performance of the currently passive smart glazing technologies. Phase Change Materials (PCMs) as latent energy storage material is the focus of this review, as well as other individual and combined techniques, including shading systems, solar cells (photovoltaic), and chromogenic (thermotropic and thermochromic) materials. PCM-integrated glazing systems have been extensively studied and rapidly developed over the past several decades from the standpoint of unique system designs, such as passive, active, and passive/active mixed designs, intelligent management, and sophisticated controls. In the academic literature, numerous studies on PCM-integrated building envelopes have been conducted, but a comprehensive review of PCM-integrated GUs combined with other passive and active techniques using dialectical analysis and comparing the climatic conditions of each study using Köppen-Geiger climate classification climate classification has been performed only rarely. Consequently, the primary objective of this study is to reduce this discrepancy for all types of glazing, excluding glazed roofs. This review article also contains literature tables as well as highlights, limitations, and further research suggestions at the end of each subsection.

12 April 2019 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
HSHamed H. Saber
Hamed H. Saber
WMWahid Maref
Wahid Maref
AHAli E. Hajiah
Ali E. Hajiah
In regions with hot climatic conditions such as that in Saudi Arabia, a substantial share of energy is used for cooling the buildings. Many studies have shown that cool (white) roofs can help reduce the cooling energy load and thus the demand for energy over time. Also, cool roofs help reduce the urban heat island during the summer time. This research study focused on determining: (a) whether cool roofs lead to risk of condensation and mold growth in Saudi climates, (b) the amount of energy savings as result of using cool roofs instead of black roofs of same insulation amount, and (c) the reduction in the amount of insulation in cool roof having the same energy performance level as the black roof. As such, numerical simulations were conducted for a roofing system that is commonly used in low-rise buildings in Saudi Arabia in order to asses and compare the energy and hygrothermal performance of cool and black roofs. The roof was subjected to weather conditions of the Eastern Province of Saudi Arabia. The indoor conditions were taken based simple method of ASHRAE Standard 160. The results showed no moisture accumulation occurred from year-to-year after 6 years and 7 years for the black roof and cool roof, respectively, and the highest relative humidities in the black and cool roofs were well below 80% resulting in no risk of condensation and mold growth occurred in these roofs. The main outcome of this study has shown the capabilities of using reflective materials with different short-wave solar absorption coefficients for enhancing the energy performance of roofs and/or reducing the amount of insulation that resulted in same energy performance as black roofs. This study can be used in future for upgrading the Saudi Building Code so as to allow less roof insulation if cool roof is installed.

14 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
WMWahid Maref
Wahid Maref
HSHamed H. Saber
Hamed H. Saber
In building applications, there is a dynamic interaction/coupling between the energy performance and the indoor air quality (IAQ) performance. Previously, the performance of energy consumption (EC) and IAQ has been evaluated independently. In this study, an energy performance model (EnergyPlus) and IAQ performance model (CONTAM: contaminant transport analysis) were simultaneously coupled as a new integrated simulation model in which the control variables were exchanged between the two models. Two scenarios were provided in this study for a three-story house. The first scenario addressed the effect of airtightness only. The second scenario, however, addressed the airtightness with an exhaust fan with an upgraded filter. In order to better analyze the accuracy of the simulations, the performance of the energy and IAQ were simulated independently using the EnergyPlus model and CONTAM model. Thereafter, the performance of the energy and IAQ were simulated using the present integrated simulation model. All simulations were conducted for the climatic conditions of Montreal and Miami. The results of the integrated simulation model showed that the exchange of control variables between both EnergyPlus and CONTAM produced accurate results for the performance of both energy and IAQ. Finally, the necessity of using the present integrated simulation model is discussed.

5 November 2019 in Frontiers in Energy Research
Verified
Journal Article
Open access
PDF file
HSHamed H. Saber
Hamed H. Saber
WMWahid Maref
Wahid Maref
Cool/white roofing systems use paints and membranes with high solar reflectivity to reflect a portion of the incident solar radiation resulting in lowering the temperature of the exterior surfaces in respect of the conventional/black roofing systems. This study focuses on the energy performance of roofing system that is being used in buildings of the Gulf Cooperation Council countries when this roof is exposed to a hot and humid climatic conditions in Saudi Arabia. The long-term moisture performance of the white and black roofing systems were investigated in a previous study in which the results showed that no risk of condensation and mold growth occurred in the roofs with different values of solar reflectivity of the rooftop and different initial construction moisture. With the same environmental conditions that were used in the previous study, the focus of this paper is on assessing the energy performance of white and black roofing systems for a wide range of: (a) thermal insulation thickness, and (b) solar reflectivity of the rooftop. Also, considerations are given in this study to develop a practical design tool that can easily be used by building engineers and architects for determining all pairs of the insulation thickness and the corresponding solar reflectivity of the reflective roofing materials/coatings that resulted in the same levels of the energy performance as those for the black roofing systems of thicker insulation thickness. The results of this study along with the developed practical design tool can be used in future to upgrade the Saudi building code to allow using less insulation in the roofs if white roofing systems are installed.

8 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
WMWahid Maref
Wahid Maref
HSHamed H. Saber
Hamed H. Saber
The overall building performance depends mainly on the energy performance, indoor air quality, and moisture performance. In order to accurately calculate the building performance, the development of a model with the ability to integrate all three performances is required. In this research, a combination of three models namely EnergyPlus for energy, CONTAM for indoor air quality, and WUFI for moisture transport are used to develop an integrated model. The mechanism of this combination is based on the exchange of temperatures, airflows, and heating-cooling flows control variables between all three sub-models. By using the paired sample t-test, an integrated model is verified and its accuracy is validated. The accuracy of the integrated model is verified by the paired sample t-test. In order to analyze the accuracy of the integrated model in comparison with single models, four scenarios of airtight fan off, airtight fan on, leaky fan off, and leaky fan on are defined for a three-story-house subjected to three different climate cities of Montreal, Vancouver, and Miami. Percentage differences of simulated measures with the ASHRAE Standard are considered as the performance criteria. The simulated results by single and integrated models are compared and analyzed. Finally, the scenarios with the high performances are evaluated in terms of energy efficiency, indoor air quality, and moisture for Montreal, Vancouver, and Miami. Overall, it can be concluded that an integrated model should be developed.