Seyedmohammadreza Heibati

Dr. Seyedmohammadreza Heibati

PhD in Engineering (Building High Performance Modeling) at Département de génie de la construction, École de technologie supérieure | Université du Québec, 1100, rue Notre-Dame Ouest, Montréal (Québec) H3C 1K3
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Energy
Verified
Journal Article
Closed access
OROmid Rahbari
Omid Rahbari
MVMajid Vafaeipour
Majid Vafaeipour
NONoshin Omar
Noshin Omar
MRMarc A. Rosen
Marc A. Rosen
Omar HegazyOmar Hegazy
Omar Hegazy
PBPeter Van Den Bossche
Peter Van Den Bossche

26 January 2017 in Environmental Progress & Sustainable Energy
Verified
Journal Article
Closed access
PDF file
ARAli Razmjoo
Ali Razmjoo
MQMojtaba Qolipour
Mojtaba Qolipour
RSReza Shirmohammadi
Reza Shirmohammadi
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
IFIraj Faraji
Iraj Faraji

14 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
WMWahid Maref
Wahid Maref
HSHamed H. Saber
Hamed H. Saber
In building applications, there is a dynamic interaction/coupling between the energy performance and the indoor air quality (IAQ) performance. Previously, the performance of energy consumption (EC) and IAQ has been evaluated independently. In this study, an energy performance model (EnergyPlus) and IAQ performance model (CONTAM: contaminant transport analysis) were simultaneously coupled as a new integrated simulation model in which the control variables were exchanged between the two models. Two scenarios were provided in this study for a three-story house. The first scenario addressed the effect of airtightness only. The second scenario, however, addressed the airtightness with an exhaust fan with an upgraded filter. In order to better analyze the accuracy of the simulations, the performance of the energy and IAQ were simulated independently using the EnergyPlus model and CONTAM model. Thereafter, the performance of the energy and IAQ were simulated using the present integrated simulation model. All simulations were conducted for the climatic conditions of Montreal and Miami. The results of the integrated simulation model showed that the exchange of control variables between both EnergyPlus and CONTAM produced accurate results for the performance of both energy and IAQ. Finally, the necessity of using the present integrated simulation model is discussed.

14 August 2018 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
AEAmirhossein Eshraghi
Amirhossein Eshraghi
GSGholam Reza Salehi
Gholam Reza Salehi
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
KLKamran Lari
Kamran Lari
A model for operating an energy hub-based multiple energy generation micro-grid is optimized using the demand response program. The optimized objective model is validated against energy demand of a residential building in Tehran, Iran. The mathematical model and optimal analysis of the proposed tri-generation micro-grid are implemented by using a real-world modelling and considering the constraints of the storage system, demand response program and the performance of the devices and the power and gas grids. The dynamic optimal operation model is prepared on the basis of the mixed integer linear programming on the subsequent day and is solved to minimize the costs of energy supply. To demonstrate the improvements, different scenarios are developed so that the renewable energy resources and storages are fed into the combined cool, heat and power system gradually. The results reveal that the inclusion of each element results in a significant improvement in the operational parameters of the micro energy grid. Scenario 1 includes a combined cool, heat and power system alone, Scenario 2 is supplemented with renewable wind and solar energy resources in addition to combined cool, heat and power system and Scenario 3 includes electrical, heat and cold storages in addition to combined cool, heat and power system and renewable energy sources. Scenario 4 is similar to Scenario 3 in terms of equipment, but the only difference lies in the use of the demand response program in the former. Total operational cost is 12.7% lower in Scenario 2 than in Scenario 1, 9.2% lower in Scenario 3 than in Scenario 2 and 8.6% lower in Scenario 4 than in Scenario 3. Practical application: An optimized operation method is prepared for combined cool, heat and power systems running in different operation modes in which renewable energy sources and storages are added to the combined cool, heat and power and the demand response program is applied. The results reveal that the cost of energy supply, including the cost of electricity, gas and pollutant emissions, is reduced and the qualitative parameters of the operation, including efficiency and reliability of building micro-grid, are increased. The proposed algorithm and the evaluation method will enable building operators to plan demand response activity on the residential building in Tehran, while this can be extended to other buildings too.

13 May 2019 in Energy & Environment
Verified
Journal Article
Closed access
PDF file
AEAmirhossein Eshraghi
Amirhossein Eshraghi
GSGholamreza Salehi
Gholamreza Salehi
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
KLKamran Lari
Kamran Lari
This research presents optimum operation strategies for multi-energy systems as combined cooling, heat, and power systems with the approach of electricity supply priority regime. A grid with energy hub structure including electrical, thermal, and cooling hubs is explored. Accordingly, an energy hub structure integrated with storages and renewable resources is designed. The mathematical model of the operation system for the presented triple generation micro-grid is considered for energy flow to the energy grid. Considering the limitations of the storage system and the performance of the equipment as well as electricity and gas line, a dynamic optimum operation model is prepared on the basis of mixed integer linear programming and is solved in general algebraic modeling system optimization software so as to minimize energy supply costs. For the model verification, different scenarios are developed in a residential building for a typical summer day so that the renewable resources and storages are fed into the system gradually. According to the findings, as each element is included in the micro-energy grid, its operational parameters, viz. the cost of electricity, gas, and pollutant emissions, are improved remarkably. Scenario I includes a combined cooling, heat, and power system, Scenario II is supplemented with renewable solar and wind energy, and Scenario III includes electrical, heat, and cold storages in addition to renewable sources and combined cooling, heat, and power system. Results reveal a decrease in total productivity cost by 12.2% in Scenario II versus Scenario I and 10.9% in Scenario III versus Scenario II.

8 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
Seyedmohammadreza HeibatiSeyedmohammadreza Heibati
Seyedmohammadreza Heibati
WMWahid Maref
Wahid Maref
HSHamed H. Saber
Hamed H. Saber
The overall building performance depends mainly on the energy performance, indoor air quality, and moisture performance. In order to accurately calculate the building performance, the development of a model with the ability to integrate all three performances is required. In this research, a combination of three models namely EnergyPlus for energy, CONTAM for indoor air quality, and WUFI for moisture transport are used to develop an integrated model. The mechanism of this combination is based on the exchange of temperatures, airflows, and heating-cooling flows control variables between all three sub-models. By using the paired sample t-test, an integrated model is verified and its accuracy is validated. The accuracy of the integrated model is verified by the paired sample t-test. In order to analyze the accuracy of the integrated model in comparison with single models, four scenarios of airtight fan off, airtight fan on, leaky fan off, and leaky fan on are defined for a three-story-house subjected to three different climate cities of Montreal, Vancouver, and Miami. Percentage differences of simulated measures with the ASHRAE Standard are considered as the performance criteria. The simulated results by single and integrated models are compared and analyzed. Finally, the scenarios with the high performances are evaluated in terms of energy efficiency, indoor air quality, and moisture for Montreal, Vancouver, and Miami. Overall, it can be concluded that an integrated model should be developed.