Due to its considerable impact on climate, bus air conditioning systems are being pushed to take a new and sustainable path. Electric buses relying on transcritical CO2 air conditioning units are perceived to be eco-friendly and future-proof solutions to achieving such a target. However, in order to have highly efficient air conditioning systems, the CO2 charge needs to be optimized. In this paper the energy and exergy-based analyses were performed to investigate the effect of normalized refrigerant charge on the system performance by using a test rig of a transcritical CO2 air conditioning unit for an 8 m electric bus. Results showed that the normalized refrigerant charge range of 0.248~0.336 was recommended in order to ensure the maximum coefficient of performance (COP). In addition, in sufficient charge conditions, the optimal COP, cooling capacity and exergy efficiency were 1.716, 18.97 kW and 29.79%, respectively, under the standard refrigeration condition of 35 °C/27 °C. As the ambient temperature rose from 35 °C to 40 °C, the COP, cooling capacity and exergy efficiency decreased by 16.03%, 10.90% and 12.22%, respectively. Furthermore, the exergy efficiency was found not to be sensitive to slightly insufficient charge, whereas overcharge was observed to be even beneficial to exergy efficiency under the condition of ensuring the maximum COP. In addition, insufficient refrigerant charging seriously affected the irreversible losses in the indoor and outdoor heat exchangers, whereas slight overcharge had little effect on the component exergy efficiency. Finally, the need to improve the CO2 compressor efficiency to enhance the system performance was revealed.

25 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AWAnci Wang
Anci Wang
JFJianmin Fang
Jianmin Fang
XYXiang Yin
Xiang Yin
YSYulong Song
Yulong Song
Feng CaoFeng Cao
Feng Cao
Paride GulloParide Gullo
Paride Gullo
The air flow rate on the gas cooler side is one of the key parameters affecting the performance and running safety of transcritical CO2 electric vehicle air conditioning systems. After experimentally analyzing the effects of the air volume flow rate in the gas cooler on the cycle parameters and system performance, a novel method to evaluate the optimal air flow rate was proposed. In addition, the effect of the gas cooler air volume flow rate on the key performance parameters of the system (e.g., optimal discharge pressure) was explored. Finally, the coupling effects of the compressor speed, ambient temperature and optimal air flow rate on the system performance was also exhaustively assessed. It was found that as the discharge temperature, the CO2 temperature at the gas cooler outlet and the discharge pressure did not vary more than ±2%, the corresponding gas cooler air volume flow rate was optimal. For the single-row and dual-process microchannel evaporator used in this work, the recommended value of the optimal gas cooler air volume flow rate was 2500 m3·h−1. The results could provide reference for the fan speed design of electric vehicle CO2 air conditioning systems, especially for the performance under idling model.

9 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
YSYulong Song
Yulong Song
HXHongsheng Xie
Hongsheng Xie
MYMengying Yang
Mengying Yang
XWXiangyu Wei
Xiangyu Wei
Feng CaoFeng Cao
Feng Cao
XYXiang Yin
Xiang Yin
To mitigate the contemporary environmental challenges and to respect the regulations on the progressive ban of hydrofluorocarbons (HFC), natural fluid CO2 was selected as an ideal refrigerant alternative in the transportation domain. In this study, the optimal CO2 charging amount and the refrigerant distribution in a bus air conditioning/heat pump system were analyzed in detail. The results showed that there was a plateau (so named by the best charging amount) of the CO2 charging amount in which the system performance reached an optimal value and maintained it nearly unchanged during this plateau while the performance declined on both sides of the plateau. In addition, the ambient temperature was found to have little effect on the determination of the refrigerant charging plateau, while the refrigerant distribution was affected by the ambient temperature to some extent. Due to the large thermal load and thermal inertia on a bus, the data and conclusions obtained are different from those of ordinary electric small passenger vehicles. This article aims to discover some quantitative parameters and lay a theoretical foundation in this field which is lacking relevant research. Through the research based on the GT-Suite simulation platform, we simulated the transcritical CO2 cycle applied on a bus, and the performance changes of the bus system (COP 1.2–2.2, refrigerating capacity 9.5–18 kW) under different charging rates (3–8 kg) were obtained.

23 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
YWYikai Wang
Yikai Wang
YHYifan He
Yifan He
YSYulong Song
Yulong Song
XYXiang Yin
Xiang Yin
Feng CaoFeng Cao
Feng Cao
Xiaolin WangXiaolin Wang
Xiaolin Wang
Given the large demand nowadays for domestic hot water, and its impact on modern building energy consumption, air source transcritical CO2 heat pumps have been extensively adopted for hot water production. Since their system efficiency is limited by significant irreversibility, a CO2-based mixture could offer a promising drop-in technology to overcome this deficiency without increasing system complexity. Although many CO2 blends have been studied in previously published literature, little has been presented about the CO2/R32 mixture. Therefore, a proposed mixture for use in transcritical CO2 heat pumps was analyzed using energy and exergy analysis. Results showed that the coefficient of performance and exergy efficiency variation displayed an “M” shape trend, and the optimal CO2/R32 mixture concentration was determined as 0.9/0.1 with regard to flammability and efficiency. The irreversibility of the throttling valve was reduced from 0.031 to 0.009 kW⋅kW−1 and the total irreversibility reduction was more notable with ambient temperature variation. A case study was also conducted to examine domestic hot water demand during the year. Pure CO2 and the proposed CO2 blend were compared with regard to annual performance factor and annual exergy efficiency, and the findings could provide guidance for practical applications in the future.