Sumit Mohanty

Dr. Sumit Mohanty

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
VMVeronika Magdanz
Veronika Magdanz
IKIslam S. M. Khalil
Islam S. M. Khalil
JSJuliane Simmchen
Juliane Simmchen
GFGuilherme P. Furtado
Guilherme P. Furtado
SMSumit Mohanty
Sumit Mohanty
SMSarthak Misra
Sarthak Misra
IRONSperms are microrobots templated by sperm cells, powered by magnetic fields, loaded with drugs, and localized by ultrasound.

18 November 2020 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
SMSumit Mohanty
Sumit Mohanty
IKIslam S. M. Khalil
Islam S. M. Khalil
SMSarthak Misra
Sarthak Misra
Acoustic actuation techniques offer a promising tool for contactless manipulation of both synthetic and biological micro/nano agents that encompass different length scales. The traditional usage of sound waves has steadily progressed from mid-air manipulation of salt grains to sophisticated techniques that employ nanoparticle flow in microfluidic networks. State-of-the-art in microfabrication and instrumentation have further expanded the outreach of these actuation techniques to autonomous propulsion of micro-agents. In this review article, we provide a universal perspective of the known acoustic micromanipulation technologies in terms of their applications and governing physics. Hereby, we survey these technologies and classify them with regards to passive and active manipulation of agents. These manipulation methods account for both intelligent devices adept at dexterous non-contact handling of micro-agents, and acoustically induced mechanisms for self-propulsion of micro-robots. Moreover, owing to the clinical compliance of ultrasound, we provide future considerations of acoustic manipulation techniques to be fruitfully employed in biological applications that range from label-free drug testing to minimally invasive clinical interventions.

1 November 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
SMSumit Mohanty
Sumit Mohanty
JZJiena Zhang
Jiena Zhang
JMJeffrey M. McNeill
Jeffrey M. McNeill
TKThom Kuenen
Thom Kuenen
FLFrederic P. Linde
Frederic P. Linde
SMSarthak Misra
Sarthak Misra

9 December 2021 in Small
Verified
Journal Article
Open access
PDF file
SMSumit Mohanty
Sumit Mohanty
APAniruddha Paul
Aniruddha Paul
PMPedro M. Matos
Pedro M. Matos
JZJiena Zhang
Jiena Zhang
JSJakub Sikorski
Jakub Sikorski
SMSarthak Misra
Sarthak Misra
Aquatic organisms within the Cephalopoda family (e.g., octopuses, squids, cuttlefish) exist that draw the surrounding fluid inside their bodies and expel it in a single jet thrust to swim forward. Like cephalopods, several acoustically powered microsystems share a similar process of fluid expulsion which makes them useful as microfluidic pumps in lab‐on‐a‐chip devices. Herein, an array of acoustically resonant bubbles are employed to mimic this pumping phenomenon inside an untethered microrobot called CeFlowBot. CeFlowBot contains an array of vibrating bubbles that pump fluid through its inner body thereby boosting its propulsion. CeFlowBots are later functionalized with magnetic layers and steered under combined influence of magnetic and acoustic fields. Moreover, acoustic power modulation of CeFlowBots is used to grasp nearby objects and release it in the surrounding workspace. The ability of CeFlowBots to navigate remote environments under magneto‐acoustic fields and perform targeted manipulation makes such microrobots useful for clinical applications such as targeted drug delivery. Lastly, an ultrasound imaging system is employed to visualize the motion of CeFlowBots which provides means to deploy such microrobots in hard‐to‐reach environments inaccessible to optical cameras.

31 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
FOFederico Ongaro
Federico Ongaro
DNDennis Niehoff
Dennis Niehoff
SMSumit Mohanty
Sumit Mohanty
SMSarthak Misra
Sarthak Misra
As robotic tools are becoming a fundamental part of present day surgical interventions, microrobotic surgery is steadily approaching clinically-relevant scenarios. In particular, minimally invasive microrobotic targeted drug deliveries are reaching the grasp of the current state-of-the-art technology. However, clinically-relevant issues, such as lack of biocompatibility and dexterity, complicate the clinical application of the results obtained in controlled environments. Consequently, in this work we present a proof-of-concept fully contactless and biocompatible approach for active targeted delivery of a drug-model. In order to achieve full biocompatiblity and contacless actuation, magnetic fields are used for motion control, ultrasound is used for imaging, and induction heating is used for active drug-model release. The presented system is validated in a three-dimensional phantom of human vessels, performing ten trials that mimic targeted drug delivery using a drug-coated microrobot. The system is capable of closed-loop motion control with average velocity and positioning error of 0.3 mm/s and 0.4 mm, respectively. Overall, our findings suggest that the presented approach could augment the current capabilities of microrobotic tools, helping the development of clinically-relevant approaches for active in-vivo targeted drug delivery.

23 June 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JSJakub Sikorski
Jakub Sikorski
SMSumit Mohanty
Sumit Mohanty
SMSarthak Misra
Sarthak Misra
Advancements in medical microrobotics have given rise to an abundance of agents capable of localised interaction with human body in small scales. Nevertheless, clinically-relevant applications of this technology are still limited by the auxiliary infrastructure required for actuation of micro-agents. In this letter, we approach this challenge. Using finite-element analysis, we show that miniaturization of electromagnets can be used to create systems capable of providing magnetic forces adequate for micro-agent steering, while retaining small footprint and power consumption. We use these observations to create MILiMAC (Microrobotic Infrastructure Loaded into Magnetically-Actuated Catheter). MILiMAC is a flexible catheter employing three miniaturized electromagnets to provide localized magnetic actuation at the deeply-seated microsurgery site. We test our approach in a proof-of-concept study deploying MILiMAC inside a test platform to deliver and steer a 600 [ $\boldsymbol{\mu }$ m] ferromagnetic microbead. The bead is steered along a set of user-defined trajectories using closed-loop position control. Across all trajectories the best performance metrics are the mean error of 0.41 [mm] and the steady-state error of 0.27 [mm].