Islam S. M. Khalil

Dr. Islam S. M. Khalil

Department of Biomechanical Engineering, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
VMVeronika Magdanz
Veronika Magdanz
IKIslam S. M. Khalil
Islam S. M. Khalil
JSJuliane Simmchen
Juliane Simmchen
GFGuilherme P. Furtado
Guilherme P. Furtado
SMSumit Mohanty
Sumit Mohanty
SMSarthak Misra
Sarthak Misra
IRONSperms are microrobots templated by sperm cells, powered by magnetic fields, loaded with drugs, and localized by ultrasound.

11 January 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
DMDalia Mahdy
Dalia Mahdy
ASAhmed El Sharkawy
Ahmed El Sharkawy
RMRamez R. Moustafa
Ramez R. Moustafa
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
MSMetin Sitti
Metin Sitti
A simple way to mitigate the potential negative side-effects associated with chemical lysis of a blood clot is to tear its fibrin network via mechanical rubbing using a helical robot. Here, we achieve mechanical rubbing of blood clots under ultrasound guidance and using external magnetic actuation. Position of the helical robot is determined using ultrasound feedback and used to control its motion toward the clot, whereas the volume of the clots is estimated simultaneously using visual feedback. We characterize the shear modulus and ultimate shear strength of the blood clots to predict their removal rate during rubbing. Our in vitro experiments show the ability to move the helical robot controllably toward clots using ultrasound feedback with average and maximum errors of ${\text{0.84}\pm \text{0.41}}$ and 2.15 mm, respectively, and achieve removal rate of $-\text{0.614} \pm \text{0.303}$ mm $^{3}$ /min at room temperature ( ${\text{25}}^{\circ }$ C) and $-\text{0.482} \pm \text{0.23}$ mm $^{3}$ /min at body temperature (37 $^{\circ}$ C), under the influence of two rotating dipole fields at frequency of 35 Hz. We also validate the effectiveness of mechanical rubbing by measuring the number of red blood cells and platelets past the clot. Our measurements show that rubbing achieves cell count of $(\text{46} \pm \text{10.9}) \times \text{10}^{4}$ cell/ml, whereas the count in the absence of rubbing is $(\text{2} \pm \text{1.41}) \times \text{10}^{4}$ cell/ml, after 40 min.

17 January 2017 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
KSKhaled Sadek
Khaled Sadek
DMDalia Mahdy
Dalia Mahdy
NHNabila Hamdi
Nabila Hamdi
MSMetin Sitti
Metin Sitti
The risk of side effects from thrombolytic agents can be minimized by using smaller doses, assisted by mechanical rubbing against blood clots using helical robots. Quantifying this observation, we study the influence of rubbing against clots on their removal rate in vitro. First, we present a hydrodynamic model of the helical robot based on the resistive-force theory to investigate the rubbing behavior of the clots using robot driven by two rotating dipole fields. Second, we experimentally evaluate the influence of the rubbing on the removal rate of the blood clots. Not only do we find that the removal rate of mechanical rubbing (-0.56 ± 0.27 mm 3 /min) is approximately three times greater than the dissolution rate of chemical lysis using streptokinase (-0.17 ± 0.032 mm 3 /min), but we also show that this removal rate can be controlled via the rubbing speed of the robot.

18 July 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
AKAnke Klingner
Anke Klingner
MSMetin Sitti
Metin Sitti
We investigate the microswimming behaviour of robotic sperms in viscous fluids. These robotic sperms are fabricated from polystyrene dissolved in dimethyl formamide and iron-oxide nanoparticles. This composition allows the nanoparticles to be concentrated within the bead of the robotic sperm and provide magnetic dipole, whereas the flexibility of the ultra-thin tail enables flagellated locomotion using magnetic fields in millitesla range. We show that these robotic sperms have similar morphology and swimming behaviour to those of sperm cells. Moreover, we show experimentally that our robotic sperms swim controllably at an average speed of approximately one body length per second (around 125 μm s−1), and they are relatively faster than the microswimmers that depend on planar wave propulsion in low-Reynolds number fluids.

20 May 2019 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
IKIslam S. M. Khalil
Islam S. M. Khalil
AAAlaa Adel
Alaa Adel
DMDalia Mahdy
Dalia Mahdy
MMMina M. Micheal
Mina M. Micheal
MMMohanad Mansour
Mohanad Mansour
SMSarthak Misra
Sarthak Misra
This work presents an approach for the localization and control of helical robots during removal of superficial blood clots inside in vitro and ex vivo models. The position of the helical robot is estimated using an array of Hall-effect sensors and precalculated magnetic field map of two synchronized rotating dipole fields. The estimated position is used to implement closed-loop motion control of the helical robot using the rotating dipole fields. We validate the localization accuracy by visual feedback and feature tracking inside the in vitro model. The experimental results show that the magnetic localization of a helical robot with diameter of 1 mm can achieve a mean absolute position error of 2.35 ± 0.4 mm (n = 20). The simultaneous localization and motion control of the helical robot enables propulsion toward a blood clot and clearing at an average removal rate of 0.67 ± 0.47 mm3/min. This method is used to localize the helical robot inside a rabbit aorta (ex vivo model), and the localization accuracy is validated using ultrasound feedback with a mean absolute position error of 2.6 mm.

30 September 2013 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
VMVeronika Magdanz
Veronika Magdanz
SSSamuel Sanchez
Samuel Sanchez
OSOliver G. Schmidt
Oliver G. Schmidt
SMSarthak Misra
Sarthak Misra
We demonstrate the closed-loop motion control of self-propelled microjets inside a fluidic microchannel. The motion control of the microjets is achieved in hydrogen peroxide solution with time-varying flow rates, under the influence of the controlled magnetic fields and the self-propulsion force. Magnetic dipole moment of the microjets is characterized using the U-turn and the rotating field techniques. The characterized magnetic dipole moment has an average of 1.4×10 -13 A.m 2 at magnetic field, linear velocity, and boundary frequency of 2 mT, 100 μm/s, and 25 rad/s, respectively. We implement a closed-loop control system that is based on the characterized magnetic dipole moment of the microjets. This closed-loop control system positions the microjets by directing the magnetic field lines toward the reference position. Experiments are done using a magnetic system and a fluidic microchannel with a width of 500 μm. In the absence of a fluid flow, our control system positions the microjets at an average velocity and within an average region-of-convergence (ROC) of 119 μm/s and 390 μm, respectively. As a representative case, we observe that our control system positions the microjets at an average velocity and within an average ROC of 90 μm/s and 600 μm and 120 μm/s and 600 μm when a flow rate of 2.5 μl/min is applied against and along the direction of the microjets, respectively. Furthermore, the average velocity and ROC are determined throughout the flow range (0 to 7.5 μl/min) to characterize the motion of the microjets inside the microchannel.