Drago Strle

Prof. Drago Strle

EE Department, University of Ljubljana, Tržaška 25, Ljubljana, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Drago StrleDrago Strle
Drago Strle
Bogdan ŠtefaneBogdan Štefane
Bogdan Štefane
EZErik Zupanič
Erik Zupanič
MTMario Trifkovic
Mario Trifkovic
MMMarijan Maček
Marijan Maček
Igor MusevicIgor Musevic
Igor Musevic
The article offers a comparison of the sensitivities for vapour trace detection of Trinitrotoluene (TNT) explosives of two different sensor systems: a chemo-mechanical sensor based on chemically modified Atomic Force Microscope (AFM) cantilevers based on Micro Electro Mechanical System (MEMS) technology with optical detection (CMO), and a miniature system based on capacitive detection of chemically functionalized planar capacitors with interdigitated electrodes with a comb-like structure with electronic detection (CE). In both cases (either CMO or CE), the sensor surfaces are chemically functionalized with a layer of APhS (trimethoxyphenylsilane) molecules, which give the strongest sensor response for TNT. The construction and calibration of a vapour generator is also presented. The measurements of the sensor response to TNT are performed under equal conditions for both systems, and the results show that CE system with ultrasensitive electronics is far superior to optical detection using MEMS. Using CMO system, we can detect 300 molecules of TNT in 10+12 molecules of N2 carrier gas, whereas the CE system can detect three molecules of TNT in 10+12 molecules of carrier N2.

27 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Anton GradisekAnton Gradisek
Anton Gradisek
MMMarion A. Van Midden
Marion A. Van Midden
MKMatija Koterle
Matija Koterle
VPVid Prezelj
Vid Prezelj
Drago StrleDrago Strle
Drago Strle
Igor MusevicIgor Musevic
Igor Musevic
We used a 16-channel e-nose demonstrator based on micro-capacitive sensors with functionalized surfaces to measure the response of 30 different sensors to the vapours from 11 different substances, including the explosives 1,3,5-trinitro-1,3,5-triazinane (RDX), 1-methyl-2,4-dinitrobenzene (DNT) and 2-methyl-1,3,5-trinitrobenzene (TNT). A classification model was developed using the Random Forest machine-learning algorithm and trained the models on a set of signals, where the concentration and flow of a selected single vapour were varied independently. It is demonstrated that our classification models are successful in recognizing the signal pattern of different sets of substances. An excellent accuracy of 96% was achieved for identifying the explosives from among the other substances. These experiments clearly demonstrate that the silane monolayers used in our sensors as receptor layers are particularly well suited to selecting and recognizing TNT and similar types of explosives from among other substances.

8 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Drago StrleDrago Strle
Drago Strle
Bogdan ŠtefaneBogdan Štefane
Bogdan Štefane
MTMario Trifkovic
Mario Trifkovic
MMMarion A. Van Midden
Marion A. Van Midden
IKIvan Kvasić
Ivan Kvasić
Igor MusevicIgor Musevic
Igor Musevic
Good chemical selectivity of sensors for detecting vapour traces of targeted molecules is vital to reliable detection systems for explosives and other harmful materials. We present the design, construction and measurements of the electronic response of a 16 channel electronic nose based on 16 differential microcapacitors, which were surface-functionalized by different silanes. The e-nose detects less than 1 molecule of TNT out of 10+12 N2 molecules in a carrier gas in 1 s. Differently silanized sensors give different responses to different molecules. Electronic responses are presented for TNT, RDX, DNT, H2S, HCN, FeS, NH3, propane, methanol, acetone, ethanol, methane, toluene and water. We consider the number density of these molecules and find that silane surfaces show extreme affinity for attracting molecules of TNT, DNT and RDX. The probability to bind these molecules and form a surface-adsorbate is typically 10+7 times larger than the probability to bind water molecules, for example. We present a matrix of responses of differently functionalized microcapacitors and we propose that chemical selectivity of multichannel e-nose could be enhanced by using artificial intelligence deep learning methods.

22 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Drago StrleDrago Strle
Drago Strle
UNUroš Nahtigal
Uroš Nahtigal
GBGraciele Batistell
Graciele Batistell
VZVincent Chi Zhang
Vincent Chi Zhang
EOErwin Ofner
Erwin Ofner
JSJohannes Sturm
Johannes Sturm
This article presents a color light detection system integrated in 130 nm CMOS technology. The sensors and corresponding electronics detect light in a CIE XYZ color luminosity space using on-chip integrated sensors without any additional process steps, high-resolution analog-to-digital converter, and dedicated DSP algorithm. The sensor consists of a set of laterally arranged integrated photodiodes that are partly covered by metal, where color separation between the photodiodes is achieved by lateral carrier diffusion together with wavelength-dependent absorption. A high resolution, hybrid, ∑∆ ADC converts each photo diode’s current into a 22-bit digital result, canceling the dark current of the photo diodes. The digital results are further processed by the DSP, which calculates normalized XYZ or RGB color and intensity parameters using linear transformations of the three photo diode responses by multiplication of the data with a transformation matrix, where the coefficients are extracted by training in combination with a pseudo-inverse operation and the least-mean square approximation. The sensor system detects the color light parameters with 22-bit accuracy, consumes less than 60 μA on average at 10 readings per second, and occupies approx. 0.8 mm2 of silicon area (including three photodiodes and the analog part of the ADC). The DSP is currently implemented on FPGA.

1 September 2016 in Integration
Verified
Journal Article
Closed access
UNUroš Nahtigal
Uroš Nahtigal
Drago StrleDrago Strle
Drago Strle