We address the problem of accurately locating buried utility segments by fusing data from multiple sensors using a novel Marching-Cross-Section (MCS) algorithm. Five types of sensors are used in this work: Ground Penetrating Radar (GPR), Passive Magnetic Fields (PMF), Magnetic Gradiometer (MG), Low Frequency Electromagnetic Fields (LFEM) and Vibro-Acoustics (VA). As part of the MCS algorithm, a novel formulation of the extended Kalman Filter (EKF) is proposed for marching existing utility tracks from a scan cross-section (scs) to the next one; novel rules for initializing utilities based on hypothesized detections on the first scs and for associating predicted utility tracks with hypothesized detections in the following scss are introduced. Algorithms are proposed for generating virtual scan lines based on given hypothesized detections when different sensors do not share common scan lines, or when only the coordinates of the hypothesized detections are provided without any information of the actual survey scan lines. The performance of the proposed system is evaluated with both synthetic data and real data. The experimental results in this work demonstrate that the proposed MCS algorithm can locate multiple buried utility segments simultaneously, including both straight and curved utilities, and can separate intersecting segments. By using the probabilities of a hypothesized detection being a pipe or a cable together with its 3D coordinates, the MCS algorithm is able to discriminate a pipe and a cable close to each other. The MCS algorithm can be used for both post- and on-site processing. When it is used on site, the detected tracks on the current scs can help to determine the location and direction of the next scan line. The proposed “multi-utility multi-sensor” system has no limit to the number of buried utilities or the number of sensors, and the more sensor data used, the more buried utility segments can be detected with more accurate location and orientation.
This paper is concerned with imaging techniques for mapping and locating underground pipeline leakage. Ground surface vibrations induced by the propagating axisymmetric wave can be measured by an array of acoustic/vibration sensors, with the extraction of magnitude information used to determine the position of leak source. A method of connected graph traversal is incorporated into the vibroacoustic technique to obtain the spatial image with better accuracy compared to the conventional magnitude contour plot. Measurements are made on a dedicated cast iron water pipe by an array of seven triaxial geophones. The spectral characteristics of the propagation of leak noise signals from underground water pipes to the ground surface are reported. Furthermore, it is demonstrated that suspicious leakage areas can be readily identified by extracting and fusing the feature patterns at low frequencies where leak noise dominates. The results agree well with the real leakage position in the underground pipeline.
1 September 2016 in Journal of Physics: Conference Series
"Mapping the Underworld" is a large multi-disciplinary, multi-university research programme taking place in the UK, which aims to revolutionize the way we undertake streetworks. Within this programme, a number of vibration-based techniques for remotely detecting and locating buried pipes have been developed. Relying either on the direct excitation of a pipe as it comes up to the surface or excitation of the ground in the vicinity of a buried pipe, mapping the ground surface vibration response allows information to be gathered concerning the pipe's exact position. However, contained within this surface response is often information which could, if utilized appropriately, provide insights into the condition of the pipe as well as its location. Furthermore, critical information regarding the condition of the ground in which a pipe is buried could, in some circumstances, be gleaned. In this paper, how this additional information might be extracted, used and eventually exploited is explored. Providing the basis for work currently being undertaken in a new programme, "Assessing the Underworld", example results are presented which demonstrate the immense potential of the proposed methods.
1 September 2016 in Journal of Physics: Conference Series
Waves that propagate at low frequencies in buried pipes are of considerable interest in a variety of practical scenarios, for example leak detection, remote pipe detection, and pipeline condition assessment and monitoring. Particularly useful are the n = 0, or axisymmetric, modes in which there is no displacement (or pressure) variation over the pipe cross section. Previous work has focused on two of the three axisymmetric wavetypes that can propagate: the s = 1, fluid- dominated wave; and the s = 2, shell-dominated wave. In this paper, the third axisymmetric wavetype, the s = 0 torsional wave, is studied. Whilst there is a large body of research devoted to the study of torsional waves and their use for defect detection in pipes at ultrasonic frequencies, little is known about their behaviour and possible exploitation at lower frequencies. Here, a low- frequency analytical dispersion relationship is derived for the torsional wavenumber for a buried pipe from which both the wavespeed and wave attenuation can be obtained. How the torsional waves subsequently radiate to the ground surface is then investigated, with analytical expressions being presented for the ground surface displacement above the pipe resulting from torsional wave motion within the pipe wall. Example results are presented and, finally, how such waves might be exploited in practice is discussed.