This paper deals with the implementation and analysis of a new maximum power point tracking (MPPT) control method, which is tested under variable climatic conditions. This new MPPT strategy has been created for photovoltaic systems based on Particle Swarm Optimization (PSO). The novel Improved Particle Swarm Optimization (IPSO) algorithm is tested in several simulations which have been implemented in view of the various system responses such as: voltage, current, and power. The performances of the proposed IPSO algorithm have been completed and compared with results of well-established methods adopted in the literature showing a higher accuracy.
This article analyzes and compares the integration of two different maximum power point tracking (MPPT) control methods, which are tested under partial shading and fast ramp conditions. These MPPT methods are designed by Improved Particle Swarm Optimization (IPSO) and a combination technique between a Neural Network and the Perturb and Observe method (NN-P&O). These two methods are implemented and simulated for photovoltaic systems (PV), where various system responses, such as voltage and power, are obtained. The MPPT techniques were simulated using the MATLAB/Simulink environment. A comparison of the performance of the IPSO and NN-P&O algorithms is carried out to confirm the best accomplishment of the two methods in terms of speed, accuracy, and simplicity.
This article analyzes and compares the integration of two different maximum power point tracking (MPPT) control methods, which are tested under partial shading and fast ramp conditions. These MPPT methods are designed by Improved Particle Swarm Optimization (IPSO) and a combination technique between Neural Network and Perturb & Observe method (NN_P&O). These two methods are implemented and simulated for photovoltaic systems (PV), where various system responses, such as: voltage and power are obtained. The MPPT techniques were simulated using Matlab/Simulink environment. A comparison of the performance of IPSO and NN_P&O algorithms is carried out to confirm the best accomplishment of the two methods in terms of speed, accuracy and simplicity.
This chapter presents an adaptive Maximum Power Point Tracking (MPPT) control framework for photovoltaic systems featuring real-time human-driven algorithm selection via an intuitive Human-Machine Interface (HMI). The platform integrates four classical algorithms—Perturb and Observe (P&O), Incremental Conductance (INC), Constant Voltage (CV), and enhanced P&O (dP-P&O)—implemented on dSPACE DS1104 hardware. Experimental evaluation under standardized staircase irradiance profiles reveals INC achieves highest efficiency (99.946%), followed by P&O (99.884%) and dP-P&O (99.780%), while CV offers computational simplicity despite lower efficiency (95.324%). This human-in-the-loop approach enables context-aware algorithm optimization without interrupting power generation, demonstrating superior adaptability compared to fixed MPPT implementations. The modular architecture supports future integration of AI-based techniques and comprehensive PV diagnostics.