Nikolas Wilhelm

Mr. Nikolas Wilhelm

Technical University of Munich, Munich, Bavaria, Germany
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Radiology
Verified
Journal Article
Closed access
CSClaudio E. von Schacky
Claudio E. von Schacky
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
VSValerie S. Schäfer
Valerie S. Schäfer
YLYannik Leonhardt
Yannik Leonhardt
FGFelix Gassert
Felix Gassert
AGAlexandra S. Gersing
Alexandra S. Gersing
A multitask deep learning model that provided classification of primary bone tumors on radiographs demonstrated performance that surpassed that of radiologic residents and was comparable with that ... Background An artificial intelligence model that assesses primary bone tumors on radiographs may assist in the diagnostic workflow. Purpose To develop a multitask deep learning (DL) model for simul...

8 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JLJan J. Lang
Jan J. Lang
MBMirjam Bastian
Mirjam Bastian
PFPeter Foehr
Peter Foehr
MSMichael Seebach
Michael Seebach
JWJochen Weitz
Jochen Weitz
RBRainer Burgkart
Rainer Burgkart
In this study, topology optimized, patient specific osteosynthesis plates (TOPOS-implants) are evaluated for the mandibular reconstruction using fibula segments. These shape optimized implants are compared to a standard treatment with miniplates (thickness: 1.0 mm, titanium grade 4) in biomechanical testing using human cadaveric specimen. Mandible and fibula of 21 body donors were used. Geometrical models were created based on automated segmentation of CT-scans of all specimens. All reconstructions, including cutting guides for osteotomy as well as TOPOS-implants, were planned using a custom-made software tool. The TOPOS-implants were produced by electron beam melting (thickness: 1.0 mm, titanium grade 5). The fibula-reconstructed mandibles were tested in static and dynamic testing in a multi-axial test system, which can adapt to the donor anatomy and apply side-specific loads. Static testing was used to confirm mechanical similarity between the reconstruction groups. Force-controlled dynamic testing was performed with a sinusoidal loading between 60 and 240 N (reconstructed side: 30% reduction to consider resected muscles) at 5 Hz for up to 5 · 105 cycles. There was a significant difference between the groups for dynamic testing: All TOPOS-implants stayed intact during all cycles, while miniplate failure occurred after 26.4% of the planned loading (1.32 · 105 ± 1.46 · 105 cycles). Bone fracture occurred in both groups (miniplates: n = 3, TOPOS-implants: n = 2). A correlation between bone failure and cortical bone thickness in mandible angle as well as the number of bicortical screws used was demonstrated. For both groups no screw failure was detected. In conclusion, the topology optimized, patient specific implants showed superior fatigue properties compared to miniplates in mandibular reconstruction. Additionally, the patient specific shape comes with intrinsic guiding properties to support the reconstruction process during surgery. This demonstrates that the combination of additive manufacturing and topology optimization can be beneficial for future maxillofacial surgery.

14 March 2024 in Artificial Intelligence in Medicine
Verified
Journal Article
Open access
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
CSClaudio E. von Schacky
Claudio E. von Schacky
FLFelix J. Lindner
Felix J. Lindner
MFMatthias J. Feucht
Matthias J. Feucht
YEYannick Ehmann
Yannick Ehmann
MRMarco-Christopher Rupp
Marco-Christopher Rupp
Osteoarthritis of the knee, a widespread cause of knee disability, is commonly treated in orthopedics due to its rising prevalence. Lower extremity misalignment, pivotal in knee injury etiology and management, necessitates comprehensive mechanical alignment evaluation via frequently-requested weight-bearing long leg radiographs (LLR). Despite LLR's routine use, current analysis techniques are error-prone and time-consuming. To address this, we conducted a multicentric study to develop and validate a deep learning (DL) model for fully automated leg alignment assessment on anterior-posterior LLR, targeting enhanced reliability and efficiency. The DL model, developed using 594 patients' LLR and a 60%/10%/30% data split for training, validation, and testing, executed alignment analyses via a multi-step process, employing a detection network and nine specialized networks. It was designed to assess all vital anatomical and mechanical parameters for standard clinical leg deformity analysis and preoperative planning. Accuracy, reliability, and assessment duration were compared with three specialized orthopedic surgeons across two distinct institutional datasets (136 and 143 radiographs). The algorithm exhibited equivalent performance to the surgeons in terms of alignment accuracy (DL: 0.21 ± 0.18°to 1.06 ± 1.3°vs. OS: 0.21 ± 0.16°to 1.72 ± 1.96°), interrater reliability (ICC DL: 0.90 ± 0.05 to 1.0 ± 0.0 vs. ICC OS: 0.90 ± 0.03 to 1.0 ± 0.0), and clinically acceptable accuracy (DL: 53.9%-100% vs OS 30.8%-100%). Further, automated analysis significantly reduced analysis time compared to manual annotation (DL: 22 ± 0.6 s vs. OS; 101.7 ± 7 s, p ≤ 0.01). By demonstrating that our algorithm not only matches the precision of expert surgeons but also significantly outpaces them in both speed and consistency of measurements, our research underscores a pivotal advancement in harnessing AI to enhance clinical efficiency and decision-making in orthopaedics.

30 September 2021 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
TDThomas Dickmann
Thomas Dickmann
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
CGClaudio Glowalla
Claudio Glowalla
SHSami Haddadin
Sami Haddadin
PSPatrick van der Smagt
Patrick van der Smagt
RBRainer Burgkart
Rainer Burgkart
This paper presents a novel mechatronic exoskeleton architecture for finger rehabilitation. The system consists of an underactuated kinematic structure that enables the exoskeleton to act as an adaptive finger stimulator. The exoskeleton has sensors for motion detection and control. The proposed architecture offers three main advantages. First, the exoskeleton enables accurate quantification of subject-specific finger dynamics. The configuration of the exoskeleton can be fully reconstructed using measurements from three angular position sensors placed on the kinematic structure. In addition, the actuation force acting on the exoskeleton is recorded. Thus, the range of motion (ROM) and the force and torque trajectories of each finger joint can be determined. Second, the adaptive kinematic structure allows the patient to perform various functional tasks. The force control of the exoskeleton acts like a safeguard and limits the maximum possible joint torques during finger movement. Last, the system is compact, lightweight and does not require extensive peripherals. Due to its safety features, it is easy to use in the home. Applicability was tested in three healthy subjects.

27 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
CDConstantin von Deimling
Constantin von Deimling
SHSami Haddadin
Sami Haddadin
CGClaudio Glowalla
Claudio Glowalla
RBRainer Burgkart
Rainer Burgkart
In this study, we developed and validated a robotic testbench to investigate the biomechanical compatibility of three total knee arthroplasty (TKA) configurations under different loading conditions, including varus–valgus and internal–external loading across defined flexion angles. The testbench captured force–torque data, position, and quaternion information of the knee joint. A cadaver study was conducted, encompassing a native knee joint assessment and successive TKA testing, featuring femoral component rotations at −5°, 0°, and +5° relative to the transepicondylar axis of the femur. The native knee showed enhanced stability in varus–valgus loading, with the +5° external rotation TKA displaying the smallest deviation, indicating biomechanical compatibility. The robotic testbench consistently demonstrated high precision across all loading conditions. The findings demonstrated that the TKA configuration with a +5° external rotation displayed the minimal mean deviation under internal–external loading, indicating superior joint stability. These results contribute meaningful understanding regarding the influence of different TKA configurations on knee joint biomechanics, potentially influencing surgical planning and implant positioning. We are making the collected dataset available for further biomechanical model development and plan to explore the 6 Degrees of Freedom (DOF) robotic platform for additional biomechanical analysis. This study highlights the versatility and usefulness of the robotic testbench as an instrumental tool for expanding our understanding of knee joint biomechanics.

25 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
SHSami Haddadin
Sami Haddadin
JLJan Josef Lang
Jan Josef Lang
CMCarina Micheler
Carina Micheler
FHFlorian Hinterwimmer
Florian Hinterwimmer
CGClaudio Glowalla
Claudio Glowalla
This paper presents the application of an adaptive exoskeleton for finger rehabilitation. The system consists of a force-controlled exoskeleton of the finger and wireless coupling to a mobile application for the rehabilitation of complex regional pain syndrome (CRPS) patients. The exoskeleton has sensors for motion detection and force control as well as a wireless communication module. The proposed mobile application allows to interactively control the exoskeleton, store collected patient-specific data, and motivate the patient for therapy by means of gamification. The exoskeleton was applied to three CRPS patients over a period of six weeks. We present the design of the exoskeleton, the mobile application with its game content, and the results of the performed preliminary patient study. The exoskeleton system showed good applicability; recorded data can be used for objective therapy evaluation.