Felix Gassert

Dr. Felix Gassert


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Radiology
Verified
Journal Article
Closed access
CSClaudio E. von Schacky
Claudio E. von Schacky
Nikolas WilhelmNikolas Wilhelm
Nikolas Wilhelm
VSValerie S. Schäfer
Valerie S. Schäfer
YLYannik Leonhardt
Yannik Leonhardt
FGFelix Gassert
Felix Gassert
AGAlexandra S. Gersing
Alexandra S. Gersing
A multitask deep learning model that provided classification of primary bone tumors on radiographs demonstrated performance that surpassed that of radiologic residents and was comparable with that ... Background An artificial intelligence model that assesses primary bone tumors on radiographs may assist in the diagnostic workflow. Purpose To develop a multitask deep learning (DL) model for simul...

29 March 2022 in Cancers
Verified
Journal Article
Open access
PDF file
SZSebastian Ziegelmayer
Sebastian Ziegelmayer
MGMarkus Graf
Markus Graf
MMMarcus Makowski
Marcus Makowski
JGJoshua Gawlitza
Joshua Gawlitza
FGFelix Gassert
Felix Gassert
Background: Lung cancer screening is already implemented in the USA and strongly recommended by European Radiological and Thoracic societies as well. Upon implementation, the total number of thoracic computed tomographies (CT) is likely to rise significantly. As shown in previous studies, modern artificial intelligence-based algorithms are on-par or even exceed radiologist’s performance in lung nodule detection and classification. Therefore, the aim of this study was to evaluate the cost-effectiveness of an AI-based system in the context of baseline lung cancer screening. Methods: In this retrospective study, a decision model based on Markov simulation was developed to estimate the quality-adjusted life-years (QALYs) and lifetime costs of the diagnostic modalities. Literature research was performed to determine model input parameters. Model uncertainty and possible costs of the AI-system were assessed using deterministic and probabilistic sensitivity analysis. Results: In the base case scenario CT + AI resulted in a negative incremental cost-effectiveness ratio (ICER) as compared to CT only, showing lower costs and higher effectiveness. Threshold analysis showed that the ICER remained negative up to a threshold of USD 68 for the AI support. The willingness-to-pay of USD 100,000 was crossed at a value of USD 1240. Deterministic and probabilistic sensitivity analysis showed model robustness for varying input parameters. Conclusion: Based on our results, the use of an AI-based system in the initial low-dose CT scan of lung cancer screening is a feasible diagnostic strategy from a cost-effectiveness perspective.

20 January 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
FGFelix Gassert
Felix Gassert
CSClaudio E. Schacky
Claudio E. Schacky
CMChristina Müller-Leisse
Christina Müller-Leisse
FGFlorian T. Gassert
Florian T. Gassert
GPGregor Pahn
Gregor Pahn
JNJonathan Nadjiri
Jonathan Nadjiri
Objective: Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important prognostic factor in coronary artery disease (CAD). The objective of this study was to evaluate the accuracy of CACS from virtual non-contrast (VNC) imaging generated from spectral data in comparison to standard (true) non-contrast (TNC) imaging in a representative patient cohort with clinically approved software. Methods: One hundred three patients referred to coronary CTA with suspicion of CAD were investigated on a dual-layer spectral detector CT (SDCT) scanner. CACS was calculated from both TNC and VNC images by software certified for medical use. Patients with a CACS of 0 were excluded from analysis. Results: The mean age of the study population was 61 ± 11 years with 48 male patients (67%). Inter-quartile range of clinical CACS was 22–282. Correlation of measured CACS from true- and VNC images was high (0.95); p < 0.001. The slope was 3.83, indicating an underestimation of VNC CACS compared to TNC CACS by that factor. Visual analysis of the Bland-Altman plot of CACS showed good accordance with both methods after correction of VNC CACS by the abovementioned factor. Conclusions: In clinical diagnostics of CAD, the determination of CACS is feasible using VNC images generated from spectral data obtained on a dual-layer spectral detector CT. When multiplied by a correction factor, results were in good agreement with the standard technique. This could enable radiation dose reductions by obviating the need for native scans typically used for CACS. Key Points: • Calcium scoring is feasible from contrast-enhanced CT images using a dual-layer spectral detector CT scanner. • When multiplied by a correction factor, calcium scoring from virtual non-contrast images shows good agreement with the standard technique. • Omitting native scans for calcium scoring could enable radiation dose reduction.

9 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
FGFelix Gassert
Felix Gassert
SBSebastian Breden
Sebastian Breden
JNJan Neumann
Jan Neumann
FGFlorian Gassert
Florian Gassert
CBChristine Theresia Bollwein
Christine Theresia Bollwein
AGAlexandra S. Gersing
Alexandra S. Gersing
The differentiation between the atypical cartilaginous tumor (ACT) and the enchondromas is crucial as ACTs require a curettage and clinical as well as imaging follow-ups, whereas in the majority of cases enchondromas require neither a treatment nor follow-ups. Differentiating enchondromas from ACTs radiologically remains challenging. Therefore, this study evaluated imaging criteria in a combination of computed tomography (CT) and magnetic resonance (MR) imaging for the differentiation between enchondromas and ACTs in long bones. A total of 82 patients who presented consecutively at our institution with either an ACT (23, age 52.7 ±18.8 years; 14 women) or an enchondroma (59, age 46.0 ± 11.1 years; 37 women) over a period of 10 years, who had undergone preoperative MR and CT imaging and subsequent biopsy or/and surgical removal, were included in this study. A histopathological diagnosis was available in all cases. Two experienced radiologists evaluated several imaging criteria on CT and MR images. Likelihood of an ACT was significantly increased if either edema within the bone (p = 0.049), within the adjacent soft tissue (p = 0.006) or continuous growth pattern (p = 0.077) were present or if the fat entrapment (p = 0.027) was absent on MR images. Analyzing imaging features on CT, the likelihood of the diagnosis of an ACT was significantly increased if endosteal scalloping >2/3 (p < 0.001), cortical penetration (p < 0.001) and expansion of bone (p = 0.002) were present and if matrix calcifications were observed in less than 1/3 of the tumor (p = 0.013). All other imaging criteria evaluated showed no significant influence on likelihood of ACT or enchondroma (p > 0.05). In conclusion, both CT and MR imaging show suggestive signs which can help to adequately differentiate enchondromas from ACTs in long bones and therefore can improve diagnostics and consequently patient management. Nevertheless, these features are rare and a combination of CT and MR imaging features did not improve the diagnostic performance substantially.

22 January 2021 in BMC Cancer
Verified
Journal Article
Open access
PDF file
FGFelix Gassert
Felix Gassert
FGFlorian Gassert
Florian Gassert
KSKatja Specht
Katja Specht
CKCarolin Knebel
Carolin Knebel
ULUlrich Lenze
Ulrich Lenze
KWKlaus Woertler
Klaus Woertler
Background: Small soft tissue masses are often falsely assumed to be benign and resected with failure to achieve tumor-free margins. Therefore, this study retrospectively investigated the distribution of histopathologic diagnosis to be encountered in small soft tissue tumors (≤ 5 cm) in a large series of a tertiary referral center. Methods: Patients with a soft tissue mass (STM) with a maximum diameter of 5 cm presenting at our institution over a period of 10 years, who had undergone preoperative Magnetic resonance imaging and consequent biopsy or/and surgical resection, were included in this study. A final histopathological diagnosis was available in all cases. The maximum tumor diameter was determined on MR images by one radiologist. Moreover, tumor localization (head/neck, trunk, upper extremity, lower extremity, hand, foot) and depth (superficial / deep to fascia) were assessed. Results: In total, histopathologic results and MR images of 1753 patients were reviewed. Eight hundred seventy patients (49.63%) showed a STM ≤ 5 cm and were therefore included in this study (46.79 +/− 18.08 years, 464 women). Mean maximum diameter of the assessed STMs was 2.88 cm. Of 870 analyzed lesions ≤ 5 cm, 170 (19.54%) were classified as superficial and 700 (80.46%) as deep. The malignancy rate of all lesions ≤ 5 cm was at 22.41% (superficial: 23.53% / deep: 22.14%). The malignancy rate dropped to 16.49% (20.79% / 15.32%) when assessing lesions ≤ 3 cm (p = 0.007) and to 15.0% (18.18% / 13.79%) when assessing lesions ≤ 2 cm (p = 0.006). Overall, lipoma was the most common benign lesion of superficial STMs (29.41%) and tenosynovial giant cell tumor was the most common benign lesion of deep STMs (23.29%). Undifferentiated pleomorphic sarcoma was the most common malignant diagnosis among both, superficial (5.29%) and deep (3.57%) STMs. Conclusions: The rate of malignancy decreased significantly with tumor size in both, superficial and deep STMs. The distribution of entities was different between superficial and deep STMs, yet there was no significant difference found in the malignancy rate.

18 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MFMatthias F. Frölich
Matthias F. Frölich
MSMoritz Ludwig Schnitzer
Moritz Ludwig Schnitzer
Adrien HolzgreveAdrien Holzgreve
Adrien Holzgreve
FGFelix Gassert
Felix Gassert
EGEva Gresser
Eva Gresser
JRJohannes Rübenthaler
Johannes Rübenthaler
Neuroendocrine tumors (NETs) are relatively rare neoplasms arising from the hormone-producing neuroendocrine system that can occur in various organs such as pancreas, small bowel, stomach and lung. As the majority of these tumors express somatostatin receptors (SSR) on their cell membrane, utilization of SSR analogs in nuclear medicine is a promising, but relatively costly approach for detection and localization. The aim of this study was to analyze the cost-effectiveness of 68Ga-DOTA-TATE PET/CT (Gallium-68 DOTA-TATE Positron emission tomography/computed tomography) compared to 111In-pentetreotide SPECT/CT (Indium-111 pentetreotide Single Photon emission computed tomography/computed tomography) and to CT (computed tomography) alone in detection of NETs. A decision model on the basis of Markov simulations evaluated lifetime costs and quality-adjusted life years (QALYs) related to either a CT, SPECT/CT or PET/CT. Model input parameters were obtained from publicized research projects. The analysis is grounded on the US healthcare system. Deterministic sensitivity analysis of diagnostic parameters and probabilistic sensitivity analysis predicated on a Monte Carlo simulation with 30,000 reiterations was executed. The willingness-to-pay (WTP) was determined to be $ 100,000/QALY. In the base-case investigation, PET/CT ended up with total costs of $88,003.07 with an efficacy of 4.179, whereas CT ended up with total costs of $88,894.71 with an efficacy of 4.165. SPECT/CT ended up with total costs of $89,973.34 with an efficacy of 4.158. Therefore, the strategies CT and SPECT/CT were dominated by PET/CT in the base-case scenario. In the sensitivity analyses, PET/CT remained a cost-effective strategy. This result was due to reduced therapy costs of timely detection. The additional costs of 68Ga-DOTA-TATE PET/CT when compared to CT alone are justified in the light of potential savings in therapy costs and better outcomes.