Josh Pooley

Josh Pooley


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Optics Express
Verified
Journal Article
Closed access
JPJosh Pooley
Josh Pooley
EPEd Price
Ed Price
JFJames W. Ferguson
James W. Ferguson
MIMorten Ibsen
Morten Ibsen
In this paper we demonstrate a simple and new fibre optic technique for measuring detonation velocities using uniform fibre Bragg gratings. We compare this new system with chirped fibre Bragg grating diagnostics and show how coherent source illumination can yield spatial uncertainties below +/- 10 mu m - a percentage error that is an order of magnitude lower than the broadband ASE methods we have tested. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

29 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JPJosh Pooley
Josh Pooley
EPEd Price
Ed Price
JFJames W. Ferguson
James W. Ferguson
MIMorten Ibsen
Morten Ibsen
Over the last decade, the use of chirped fibre Bragg gratings (CFBGs) in detonation velocity experiments has been steadily increasing. In this paper, we show how CFBG design parameters—chirp-rate, reflectivity and apodisation—affect linearity in detonation velocity tests. It is found that the optimal CFBG detonation velocity probe should have a high chirp-rate, a low reflectivity and no apodisation. As a further demonstration of these findings, we measure detonation velocity with a 24 cm optimised CFBG; the longest CFBG test of this kind so far.

10 April 2019 in Sensors
Verified
Journal Article
Open access
JPJosh Pooley
Josh Pooley
EPEd Price
Ed Price
JFJames W. Ferguson
James W. Ferguson
MIMorten Ibsen
Morten Ibsen
In this paper, a simple detonation velocity measurement scheme is presented, which exploits the length-dependent amplified spontaneous emission (ASE) power emitted by off-the-shelf Er-doped fibres. This measurement scheme is first calibrated using cutback tests, so that minimal processing is required between data collection and velocity readout. We then demonstrate the use of this method in an explosive cylinder test and achieve a spatial resolution of approximately ±2 mm, owing to its implementation in a helical geometry. Alongside the standard Er fibres, a specially made, high-concentration Er/Yb-doped fibre is also calibrated, which demonstrates a potential spatial resolution approaching ±20 μ m.