Morten Ibsen

Morten Ibsen


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2003 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MIMorten Ibsen
Morten Ibsen
RFRicardo Feced
Ricardo Feced
Single-fiber Bragg gratings designed to compensate for pure third-order dispersion are demonstrated. The devices are designed by use of a layer-peeling inverse-scattering technique and exhibit dispersion profiles across their reflection bandwidths of -20,±40, and -225 ps/nm2 over bandwidths of 4.5, 6, and 3 nm, respectively. Furthermore, they have almost constant peak reflectivities of ∼75% and are, respectively, only 8, 23, and 40 mm long.

5 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
SYStephanie Hui Kit Yap
Stephanie Hui Kit Yap
YTYung Chuen Tan
Yung Chuen Tan
Swee Chuan TjinSwee Chuan Tjin
Swee Chuan Tjin
MIMorten Ibsen
Morten Ibsen
WLWenn Jing Lai
Wenn Jing Lai
We present a novel superstructure fiber Bragg grating fiber end sensor capable of detecting variations in refractive index (RI) of liquids and potentially that of gases, and demonstrated an application in the detection of heavy metal ions in water. The sensor is capable of sensing RI variations in the range of 1.333 to 1.470 with good sensitivity of up to 230 dB/RIU achieved for the RI range of 1.370 to 1.390. The sensor is capable of simultaneously measuring variations in ambient temperature along with RI. A simple chemical coating was employed as a chelating agent for heavy metal ion detection at the fiber end to demonstrate an possible application of the sensor. The coated fiber sensor can conclusively detect the presence of heavy metal ions with concentrations upwards of 100 ppm. RI sensing capability of the sensor is neither affected by temperature nor strain and is both robust and easily reproducible.

29 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
DHDaryl Ho
Daryl Ho
CTChun Ho Tse
Chun Ho Tse
YTYung Chuen Tan
Yung Chuen Tan
SYSeongwoo Yoo
Seongwoo Yoo
MIMorten Ibsen
Morten Ibsen
We demonstrate a simple-to-fabricate refractometer based on the inscription of fiber Bragg gratings in a special C-shaped optical fiber. The C-shaped fiber was drawn into shape using a quarter cladding removed preform of a commercial standard single-mode fiber by simple machining. The sensor did not suffer from cross-sensitivity of the refractive index with ambient temperature fluctuations, commonly occurring with many optical fiber refractometers. A refractive index sensitivity of 1300 pm per refractive index unit (RIU) was achieved without employing any additional sensitization techniques such as tapering or etching.

5 December 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
MIMorten Ibsen
Morten Ibsen
Swee Chuan TjinSwee Chuan Tjin
Swee Chuan Tjin
Research into optical fiber refractometers yielded remarkable results over the past decade. Numerous sensing schemes were proposed and demonstrated, which possessed different advantages while facing unique limitations. On top of their obvious applications in measuring refractive index changes of the ambient environment, several studies reported advanced applications of such sensors in heavy metal ion detection by means of surface coating of the refractometers with heavy metal ion sensitive materials. This paper surveys the effort these optical fiber metal ion sensors based on surface coated optical fiber refractometer, discusses different technologies and methods involved, and highlights recent notable advancements.

1 August 2019 in Optics Express
Verified
Journal Article
Closed access
JPJosh Pooley
Josh Pooley
EPEd Price
Ed Price
JFJames W. Ferguson
James W. Ferguson
MIMorten Ibsen
Morten Ibsen
In this paper we demonstrate a simple and new fibre optic technique for measuring detonation velocities using uniform fibre Bragg gratings. We compare this new system with chirped fibre Bragg grating diagnostics and show how coherent source illumination can yield spatial uncertainties below +/- 10 mu m - a percentage error that is an order of magnitude lower than the broadband ASE methods we have tested. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

29 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JPJosh Pooley
Josh Pooley
EPEd Price
Ed Price
JFJames W. Ferguson
James W. Ferguson
MIMorten Ibsen
Morten Ibsen
Over the last decade, the use of chirped fibre Bragg gratings (CFBGs) in detonation velocity experiments has been steadily increasing. In this paper, we show how CFBG design parameters—chirp-rate, reflectivity and apodisation—affect linearity in detonation velocity tests. It is found that the optimal CFBG detonation velocity probe should have a high chirp-rate, a low reflectivity and no apodisation. As a further demonstration of these findings, we measure detonation velocity with a 24 cm optimised CFBG; the longest CFBG test of this kind so far.