Bong Hwan Hong

Bong Hwan Hong


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
EPEdit Profile Edit Profile
Edit Profile Edit Profile
OKOhjoon Kwon
Ohjoon Kwon
MSMatlabjon Sattorov
Matlabjon Sattorov
SKSeontae Kim
Seontae Kim
DHDongpyo Hong
Dongpyo Hong
GPGun-Sik Park
Gun-Sik Park
Characteristic x rays generated by a collision between a tungsten target and relativistic electron beams generated from a compact electrostatic accelerator based on a Marx generator and a Blumlein pulse-forming line can induce transient ionizing radiation in electronics. While the decelerated electron beam is close to a collector out of range of an external magnetic field, Bremsstrahlung x rays occur at the same time. Compton scattering also occurs through secondary reaction interactions with quasi-stationary particles such as ejected inner shell electrons or photons. During a simulation, a semiconductor process is used to analyze the effects and processes of photocurrents derived from the flow of the drain current when transient pulses generated from the compact electrostatic accelerator are incident in the pMOSFET-AD420-based detector. The photocurrent induced from the detector is also measured by experimental results in comparison with a computer simulation, and a photocurrent detection experiment was then conducted with a high-pulse-current compact electrostatic accelerator. In addition, data pertaining to the irradiation dose rate and photon emission rate were obtained. In order to confirm the radiation pattern in the situation of Compton scattering, the ionizing radiation effect in the photosensitive phosphor was identified using a fluorescent lamp. During the experiment, a relativistic electron beam operating at high energy and current levels at a maximum of 1MeV-10 kA was utilized.

1 June 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
EPEdit Profile Edit Profile
Edit Profile Edit Profile
CPChawon Park
Chawon Park
MKMinho Kim
Minho Kim
HJHyunwoo Jung
Hyunwoo Jung
JBJongHyun Back
JongHyun Back
BHBong Hwan Hong
Bong Hwan Hong
The boron neutron capture therapy (BNCT) system developed by the Korea Institute of Radiological and Medical Sciences is a compact neutron source that can be installed at medical institutes. The target energy was accelerated to a maximum of 2.4 MeV–20 mA by introducing a gas stripping device that converts negative hydrogen ions into positive ions. By using the tandem-type accelerator in this way, a high-voltage DC power supply was designed with 1.2 MV–45 mA as the maximum capability. The design was improved to reduce the number of stages of a Cockcroft–Walton voltage multiplier. Hence, the ripple risk of the DC flat top resulting from unwanted stray capacitance was lowered. The overall height and volume of the Cockcroft–Walton voltage multiplier were reduced to less than half those of the existing design method, making miniaturization possible. After such advanced design and manufacturing, performance tests were performed at 750 kV–45 mA under 23 stages of the Cockcroft–Walton voltage multiplier, which is the highest level that can perform at its maximum under in-air conditions. It demonstrated stable performance under in-air conditions without breakdown for 2 h, even at 620 kV–35 mA. To reach the final target of 1.2 MV–45 mA, the groundwork is laid for achieving experimental performance while satisfying the optimal requirements in SF6 gas.

12 April 2025 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
CPChawon Park
Chawon Park
MKMinho Kim
Minho Kim
HJHyunwoo Jung
Hyunwoo Jung
WHWon Taek Hwang
Won Taek Hwang
BHBong Hwan Hong
Bong Hwan Hong

1 November 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EPEdit Profile Edit Profile
Edit Profile Edit Profile
HJHoechun Jung
Hoechun Jung
OKOhjoon Kwon
Ohjoon Kwon
MSMatlabjon Sattorov
Matlabjon Sattorov
SKSeontae Kim
Seontae Kim
GPGun-Sik Park
Gun-Sik Park
Versatile high-power pulsed electron-beam accelerators that meet the requirements of pulsed high-power specifications are needed for appropriate applications in medical industry, defense, and other industries. The pulsed electron beam accelerator comprising a Marx generator and Blumlein pulse forming line (PFL) is designed to accelerate the electron beams at the level of 1 MeV when electrostatically discharging. The performance specifications of Marx generators consisting of a 100 kV DC power supply, R-L-C circuit, and high voltage switch are at a maximum 800 kV. At this time, by using the capacitance mismatching principle between the Marx generator and the Blumlein PFL under the law of preserving the amount of charge, it is possible to generate a high voltage in the form of a square pulse up to about 1.1 MV, as much as 1.37 times the charged voltage of the Marx generator. As a result, energy transmission from the Marx generator with a high efficiency of about 85% to the Blumlein PFL is possible. The aim of this study is that the pulsed high-power electron-beam accelerator can be used to change the diode impedance, and the energy of the accelerated electron beam reaches a level of 1 MeV with the square pulse width of about 100 ns at the flat-top in the range of relativistic electron beam generation. Performance tests were securely carried out by installing a dummy load based on CuSO4 solution varying the diode impedance to deter damage to the circuit by preventing reflected waves from being generated in the load.

1 February 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
EPEdit Profile Edit Profile
Edit Profile Edit Profile
CPChawon Park
Chawon Park
SMSukhwal Ma
Sukhwal Ma
MKMinho Kim
Minho Kim
KKKyeong Min Kim
Kyeong Min Kim
BHBong Hwan Hong
Bong Hwan Hong
To build a proton beam accelerator that can be applied to a boron neutron capture therapy system based on an electrostatic accelerator, a high-voltage direct-current (DC) power supply system equivalent to the generation of neutrons should be provided. The symmetrical Cockcroft–Walton voltage multiplier method is suitable for stable acceleration of the proton beam in the tandem electrostatic accelerator in this system. Before the second step-up with the Cockcroft–Walton circuit, the design of the inverter is prioritized by preponderantly considering the first voltage and resonance frequency. Moreover, the optimized stacking number is determined with consideration of the ripple voltage, voltage drop, average output voltage, and fundamental harmonics, and a design is performed to set related parameter values to be stable in the flat-top region of the voltage. A high-voltage DC power supply system of 1.2 MV/45 mA is needed for a stable terminal energy of 2.4 MeV/20 mA. Such a design can be optimized by securing reliable data using a simulation tool on the basis of theoretical calculations. This will become a formidable touchstone in manufacturing technology based on acquiring practical know-how for setting up a tandem electrostatic accelerator-based boron neutron capture therapy system in the future.

1 February 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CPChawon Park
Chawon Park
MKMinho Kim
Minho Kim
HJHyunwoo Jung
Hyunwoo Jung
SPSeungwoo Park
Seungwoo Park
BHBong Hwan Hong
Bong Hwan Hong
This paper presents the development of a 1.2 MV high-voltage direct current (DC) power supply with an SF6 insulation for an electrostatic tandem proton accelerator utilized in an accelerator-based boron neutron capture therapy (BNCT) system. BNCT offers a promising alternative to traditional radiation therapy for the treatment of malignant brain tumors, head and neck cancers, and melanomas. The electrostatic tandem proton accelerator system, designed to produce H− ions and subsequently accelerate them to generate protons, represents a significant advancement in medical technology. Key milestones in the process include generating and maintaining a high-voltage DC power supply of 1.2 MV/45 mA for over 30 min, with rigorously testing conducted up to 750 kV/45 mA in ambient conditions. The system features an upgraded Cockcroft–Walton rectifier stage and incorporates a realistic load resistance, with final testing conducted in a tank filled with SF6 gas. Performance tests conducted in atmospheric and SF6 gas environments demonstrate the stable operation of the power supply up to 1.2 MV/45 mA, despite challenges such as corona discharge and electrical arcing in atmospheric environments. It demonstrates excellent long-term voltage and current stability, proving its suitability for tandem proton accelerators by reliably supplying 54 W of power to the dummy load. The developed system can enhance the effectiveness of BNCT systems by generating high-current proton beams, leading to improved treatment outcomes.