Characteristic x rays generated by a collision between a tungsten target and relativistic electron beams generated from a compact electrostatic accelerator based on a Marx generator and a Blumlein pulse-forming line can induce transient ionizing radiation in electronics. While the decelerated electron beam is close to a collector out of range of an external magnetic field, Bremsstrahlung x rays occur at the same time. Compton scattering also occurs through secondary reaction interactions with quasi-stationary particles such as ejected inner shell electrons or photons. During a simulation, a semiconductor process is used to analyze the effects and processes of photocurrents derived from the flow of the drain current when transient pulses generated from the compact electrostatic accelerator are incident in the pMOSFET-AD420-based detector. The photocurrent induced from the detector is also measured by experimental results in comparison with a computer simulation, and a photocurrent detection experiment was then conducted with a high-pulse-current compact electrostatic accelerator. In addition, data pertaining to the irradiation dose rate and photon emission rate were obtained. In order to confirm the radiation pattern in the situation of Compton scattering, the ionizing radiation effect in the photosensitive phosphor was identified using a fluorescent lamp. During the experiment, a relativistic electron beam operating at high energy and current levels at a maximum of 1MeV-10 kA was utilized.
19 November 2020 in Journal of the Korean Physical Society
Boron neutron capture therapy (BNCT) is a more efficient cancer treatment method compared to direct radiation therapy using charged particles such as protons or carbon beams. Particularly, accelerator-based BNCT (AB-BNCT) is attracting attention due to easy construction in a hospital. The Korea Institute of Radiological & Medical Sciences (KIRAMS) has constructed an injection system for an electrostatic AB-BNCT accelerator and commissioned 30 keV H− and 5 keV D− ion beam facilities. The beam characteristic parameters and Twiss parameters should be confirmed experimentally, and various methods have to be applied for the related measurements. In this study, the linear matrix formalism is used as a technique to measure the beam characteristic and Twiss parameters by varying the magnetic field strength of a solenoid in the beam line. To confirm the validity of this method, a multi-particle tracking code was executed. The simulation results confirm that the proposed method is effective for extracting Twiss parameters. After verification via the multi-particle tracking code, the method was applied to perform experimental measurements. Notably, the method accurately obtains the transverse beam emittance within reasonable uncertainty levels. Thus, our results show that the proposed method is a convenient technique for extracting the Twiss parameters indirectly. The results of the Twiss parameter measurement can potentially be more precise if other aspects, such as the quadrupole magnetic field strength, are incorporated.
A klystron is an important vacuum device which is useful in medical linear accelerators because it amplifies the radio-frequency (RF) signals required to produce high-energy particle beams. The properties of the nonlinear input and output dynamics in the klystron circuit arouse distortion in various types of parameters pertaining to the beam voltage, beam current, RF power, and operating frequency from unpredictable external factors. Therefore, low-level RF (LLRF) control systems can facilitate the regulation of the output of the klystron to a desired level. Low-level RF control system of the klystron is designed to stabilize the applied voltage and control the resonance frequency of the cavity of the klystron. In this work, an infallible low-level RF control system, the most suitable for a klystron, is designed to use a beam monitoring and an interlock system with components that include an isolator and a phase shifter. Moreover, with regard to pulse distortion at the flap top at the RF output power, the stability of the RF power pulse at the flap top part was improved somewhat by a variable inductor which controlled the inside of the pulse modulator. In this LLRF control experiment, the pulse modulator generated 140kV-95A and succeeded in generating RF output power of 2.856GHz-6MW level of an S-band klystron. During this process, the efficiency of the RF power was approximately 42∼45% and the pulse repetition rate was 10 Hz. The flattop pulse width was measured and found to be 1 µs.
22 February 2015 in Journal of the Korean Physical Society
In order to produce a 430 MeV/u carbon ion (12C6+) beam for medical therapy, the Korea Institute of Radiological & Medical Sciences (KIRAMS) has carried out the development of a superconducting isochronous cyclotron, the KIRAMS-430. At the extraction of the cyclotron, an Energy Selection System (ESS) is located to modulate the fixed beam energy and to drive the ion beam through High Energy Beam Transport (HEBT) into the treatment room. The beam emittance at the ion beamline is to be measured to provide information on designing a beam with high quality. The well-known quadrupole variation method was used to determine the feasibility of measuring the transverse beam emittance. The beam size measured at the beam profile monitor (BPM) is to be utilized and the transformation of beam by transfer matrix is to be applied being taken under various transport condition of varying quadrupole magnetic strength. Two different methods where beam optics are based on the linear matrix formalism and particle tracking with a 3-D magnetic field distribution obtained by using OPERA3D TOSCA, are applied to transport the beam. The fittings for the transformation parameters are used to estimate the transverse emittance and the twiss parameters at the entrance of the quadrupole in the ESS. Including several systematic studies, we conclude that within the uncertainty the estimated emittances are consistent with the ones calculated by using Monte Carlo simulations.
The boron neutron capture therapy (BNCT) system developed by the Korea Institute of Radiological and Medical Sciences is a compact neutron source that can be installed at medical institutes. The target energy was accelerated to a maximum of 2.4 MeV–20 mA by introducing a gas stripping device that converts negative hydrogen ions into positive ions. By using the tandem-type accelerator in this way, a high-voltage DC power supply was designed with 1.2 MV–45 mA as the maximum capability. The design was improved to reduce the number of stages of a Cockcroft–Walton voltage multiplier. Hence, the ripple risk of the DC flat top resulting from unwanted stray capacitance was lowered. The overall height and volume of the Cockcroft–Walton voltage multiplier were reduced to less than half those of the existing design method, making miniaturization possible. After such advanced design and manufacturing, performance tests were performed at 750 kV–45 mA under 23 stages of the Cockcroft–Walton voltage multiplier, which is the highest level that can perform at its maximum under in-air conditions. It demonstrated stable performance under in-air conditions without breakdown for 2 h, even at 620 kV–35 mA. To reach the final target of 1.2 MV–45 mA, the groundwork is laid for achieving experimental performance while satisfying the optimal requirements in SF6 gas.