Steve H. Faulkner

Dr. Steve H. Faulkner

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
SHSven P. Hoekstra
Sven P. Hoekstra
NBNicolette C. Bishop
Nicolette C. Bishop
SFSteve H. Faulkner
Steve H. Faulkner
SBStephen Bailey
Stephen Bailey
CLChristof Leicht
Christof Leicht
Regular exercise-induced acute inflammatory responses are suggested to improve the inflammatory profile and insulin sensitivity. As body temperature elevations partly mediate this response, passive heating might be a viable tool to improve the inflammatory profile. This study investigated the acute and chronic effects of hot water immersion on inflammatory and metabolic markers. Ten sedentary, overweight men [body mass index (BMI): 31.0 ± 4.2 kg/m2, mean ± SD] were immersed in water set at 39°C for 1 h (HWI) or rested for 1 h at ambient temperature (AMB). Venous blood was obtained before the session, immediately postsession, and 2 h postsession for assessment of monocyte intracellular heat shock protein-72 (iHsp72) and plasma concentrations of extracellular Hsp72 (eHsp72), interleukin-6 (IL-6), fasting glucose, insulin, and nitrite. Thereafter, participants underwent a 2-wk intervention period, consisting of 10 hot water immersion sessions (INT). Eight BMI-matched participants (BMI: 30.0 ± 2.5 kg/m2) were included as control (CON). Plasma IL-6 and nitrite concentrations were higher immediately following HWI compared with AMB (IL-6 P < 0.001, HWI: 1.37 ± 0.94 to 2.51 ± 1.49 pg/ml; nitrite P = 0.04, HWI: 271 ± 52 to 391 ± 72 nM), whereas iHsp72 expression was unchanged ( P = 0.57). In contrast to resting iHsp72 expression ( P = 0.59), fasting glucose ( P = 0.04; INT: 4.44 ± 0.93 to 3.98 ± 0.98 mmol/l), insulin ( P = 0.04; INT: 68.1 ± 44.6 to 55.0 ± 29.9 pmol/l), and eHsp72 ( P = 0.03; INT: 17 ± 41% reduction) concentrations were lowered after INT compared with CON. HWI induced an acute inflammatory response and increased nitric oxide bioavailability. The reductions in fasting glucose and insulin concentrations following the chronic intervention suggest that hot water immersion may serve as a tool to improve glucose metabolism. NEW & NOTEWORTHY A single hot water immersion (HWI) session induces an acute increase in plasma interleukin-6 and nitrite concentrations but does not acutely elevate heat shock protein-72 expression in monocytes [intracellular Hsp72 (iHsp72)]. A chronic HWI intervention reduces fasting glucose and insulin concentrations in the absence of changes in resting iHsp72. Therefore, HWI shows potential as a strategy to combat chronic low-grade inflammation and improve glucose metabolism in individuals without the physical capacity to do so using exercise.

1 October 2009 in Ageing Research Reviews
Verified
Journal Article
Closed access
ASAmarjit Saini
Amarjit Saini
SFSteve H. Faulkner
Steve H. Faulkner
NANasser Al-Shanti
Nasser Al-Shanti
CSClaire Stewart
Claire Stewart

1 February 2013 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Open access
SFSteve H. Faulkner
Steve H. Faulkner
RFRichard A. Ferguson
Richard A. Ferguson
NGNicola Gerrett
Nicola Gerrett
MHMaarten Hupperets
Maarten Hupperets
SHSimon G. Hodder
Simon G. Hodder
GHGeorge Havenith
George Havenith
Height = 1.82 ± 0.72 m, body mass = 77.9 ± 9.8 kg; mean ± SD) completed a standardized 15-min intermittent warm-up on a cycle ergometer, followed by a 30-min passive recovery period before completing a 30-s maximal sprint test. Muscle temperature was measured in the vastus lateralis at 1, 2, and 3 cm depth before and after the warm-up and immediately before the sprint test. Absolute and relative peak power output was determined and blood lactate concentration was measured immediately after exercise. During the recovery period, participants wore a tracksuit top and (i) standard tracksuit pants (CONT), (ii) insulated athletic pants (INS), or (iii) insulated athletic pants with integrated electric heating elements (HEAT). Results Warm-up increased Tm by approximately 2.5°C at all depths, with no differences between conditions. During recovery, Tm remained elevated in HEAT compared with INS and CONT at all depths (P < 0.001). Both peak and relative power output were elevated by 9.6% and 9.1%, respectively, in HEAT compared with CONT (both P < 0.05). The increase in blood lactate concentration was greater (P < 0.05) after sprint in HEAT (6.3 ± 1.8 mmol·L−1) but not INS (4.0 ± 1.8 mmol·L−1) versus CONT (4.1 ± 1.9 mmol·L−1). Conclusions Passive heating of the thighs between warm-up completion and performance execution using pants incorporating electrically heated pads can attenuate the decline in Tm and improve sprint cycling performance....

9 March 2017 in Temperature
Verified
Journal Article
Open access
SFSteve H. Faulkner
Steve H. Faulkner
SJS. Jackson
S. Jackson
GFG. Fatania
G. Fatania
CLChristof Leicht
Christof Leicht
Increasing physical activity remains the most widely publicized way of improving health and wellbeing. However, in populations that benefit most from exercise (EX), adherence is often poor and alternatives to EX are important to bring about health improvements. Recent work suggests a role for passive heating (PH) and heat shock proteins (HSP) in improving cardio-metabolic health. The aim of this study was to investigate the expression of HSP70 and interleukin-6 in response to either EX or PH and the subsequent effect on glucose control. Fourteen males volunteered and were categorized lean (BMI 23.5 ± 2.2 kg·m−2) or overweight (29.2 ± 2.7 kg·m−2) and completed 60 minutes of either moderate cycling at a fixed rate of metabolic heat production (EX) or warm water immersion in 40°C water (PH). Extracellular HSP70 increased from baseline in both conditions with no differences between PH (0.98 ± 1.1 ng·mL−1) or EX (0.84 ± 1.0 ng·mL−1, p = 0.814). IL-6 increased following both conditions with a two-fold increase after PH and four-fold after EX. Energy expenditure increased by 61.0 ± 14.4 kcal·h−1 (79%) after PH. Peak glucose concentration after a meal immediately following PH was reduced when compared with EX (6.3 ± 1.4 mmol·L−1 versus 6.8 ± 1.2 mmol·L−1; p < 0.05). There was no difference in 24-hour glucose area under the curve (AUC) between conditions. These data indicate the potential for thermal therapy as an alternative treatment and management strategy for those at risk of developing metabolic disease where adherence, or ability to EX, may be compromised.

22 April 2015 in Physiological Reports
Verified
Journal Article
Open access
PDF file
JPJamie K. Pugh
Jamie K. Pugh
SFSteve H. Faulkner
Steve H. Faulkner
AJAndrew P. Jackson
Andrew P. Jackson
James KingJames King
James King
MNMyra Nimmo
Myra Nimmo
Concurrent training involving resistance and endurance exercise may augment the benefits of single-mode training for the purpose of improving health. However, muscle adaptations, associated with resistance exercise, may be blunted by a subsequent bout of endurance exercise, via molecular interference. High-intensity interval training (HIIT), generating similar adaptations to endurance exercise, may offer an alternative exercise mode to traditional endurance exercise. This study examined the influence of an acute HIIT session on the molecular responses following resistance exercise in untrained skeletal muscle. Ten male participants performed resistance exercise (4 × 8 leg extensions, 70% 1RM, (RE)) or RE followed by HIIT (10 × 1 min at 90% HRmax, (RE+HIIT)). Muscle biopsies were collected from the vastus lateralis before, 2 and 6 h post-RE to determine intramuscular protein phosphorylation and mRNA responses. Phosphorylation of Akt (Ser473) decreased at 6 h in both trials (P < 0.05). Phosphorylation of mTOR (Ser2448) was higher in RE+HIIT (P < 0.05). All PGC-1α mRNA variants increased at 2 h in RE+HIIT with PGC-1α and PGC-1α-ex1b remaining elevated at 6 h, whereas RE-induced increases at 2 and 6 h for PGC-1α-ex1b only (P < 0.05). Myostatin expression decreased at 2 and 6 h in both trials (P < 0.05). MuRF-1 was elevated in RE+HIIT versus RE at 2 and 6 h (P < 0.05). Atrogin-1 was lower at 2 h, with FOXO3A downregulated at 6 h (P < 0.05). These data do not support the existence of an acute interference effect on protein signaling and mRNA expression, and suggest that HIIT may be an alternative to endurance exercise when performed after resistance exercise in the same training session to optimize adaptations.

24 April 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
Jingfeng HuangJingfeng Huang
Jingfeng Huang
HCHu Chen
Hu Chen
WNWenbin Niu
Wenbin Niu
DFDerrick W. H. Fam
Derrick W. H. Fam
APAlagappan Palaniappan
Alagappan Palaniappan
ATAlfred Tok
Alfred Tok
Graphene Oxide (GO) is analogous to graphene with oxygen moieties. It offers several advantages over graphene, such as a tunable band-gap, facile synthesis and no use of metal catalysts. Due to the monolayer configuration of GO, all of its carbon atoms are readily exposed to the atmosphere and are sensitive to surface perturbations, thus making GO very suitable for liquid-gated field effect transistor (FET) type sensing applications. However, there are two main limitations preventing GO usage in practical FET sensors. It displays (1) variable coverage between fabricated chips and (2) high electrical resistance. In this paper, we overcome these two limitations by using a facile atmospheric-pressure ethanol Chemical Vapor Deposition treatment on top of pre-coated GO (ECVDGO) which decreases the electrical resistivity from 1.99 × 106 Ω square−1 to 4.68 × 103 Ω square−1, and resistivity variation from 1.60 × 106 to 7.72 × 102 Ω square−1; whilst enlarging the surface GO coverage up to 100%. We then demonstrate the ability of the post-treated ECVDGO liquid-gated FET transducer to detect Interleukin-6 which is a multi-functional cytokine involved in regulating the immune function and the acute phase response. The sensing window of the fabricated biosensor to Interleukin-6 is within the physiologically-relevant range, from 4.7 to 300 pg ml−1. The LOD of the sensor based on 3σ is 2.9 pA or 1.53 pg ml−1. This study demonstrates the emerging potential of GO with high manufacturability in liquid-gated FET biosensors for sensitive and label-free detection of bio-molecules.