Jingfeng Huang

Dr. Jingfeng Huang

Republic Polytechnic, School of Engineering, 9 Woodlands Ave 9, Singapore 738964, Singapore
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2012 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
XTXue Teng
Xue Teng
YZYihan Zhu
Yihan Zhu
WWwei Wei
wei Wei
SWShuchao Wang
Shuchao Wang
Jingfeng HuangJingfeng Huang
Jingfeng Huang
LHLing Huang
Ling Huang

3 March 2016 in Analytical Chemistry
Verified
Journal Article
Open access
HCHu Chen
Hu Chen
PCPeng Chen
Peng Chen
Jingfeng HuangJingfeng Huang
Jingfeng Huang
RSRobert Selegård
Robert Selegård
MPMark Platt
Mark Platt
BLBo Liedberg
Bo Liedberg
A novel approach for rapid and sensitive detection of matrilysin (MMP-7, a biomarker involved in the degradation of various macromolecules) based on a polypeptide (JR2EC) functionalized reduced graphene oxide (rGO) field effect transistor (FET) is reported. MMP-7 specifically digests negatively charged JR2EC immobilized on rGO, thereby modulating the conductance of rGO-FET. The proposed assay enabled detection of MMP-7 at clinically relevant concentrations with a limit of detection (LOD) of 10 ng/mL (400 pM), attributed to the significant reduction of the net charge of JR2EC upon digestion by MMP-7. Quantitative detection of MMP-7 in human plasma was further demonstrated with a LOD of 40 ng/mL, illustrating the potential for the proposed methodology for tumor detection and carcinoma diagnostic (e.g., lung cancer and salivary gland cancer). Additionally, excellent specificity of the proposed assay was demonstrated using matrix metallopeptidase 1 (MMP-1), a protease of the same family. With appropriate selection and modification of polypeptides, the proposed assay could be extended for detection of other enzymes with polypeptide digestion capability.

1 January 2016 in Materials & Design
Verified
Journal Article
Closed access
HCHu Chen
Hu Chen
TCTeck Kian Choo
Teck Kian Choo
Jingfeng HuangJingfeng Huang
Jingfeng Huang
WYWang Yi
Wang Yi
YLYuanjun Liu
Yuanjun Liu
ATAlfred Tok
Alfred Tok

24 April 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
Jingfeng HuangJingfeng Huang
Jingfeng Huang
HCHu Chen
Hu Chen
WNWenbin Niu
Wenbin Niu
DFDerrick W. H. Fam
Derrick W. H. Fam
APAlagappan Palaniappan
Alagappan Palaniappan
ATAlfred Tok
Alfred Tok
Graphene Oxide (GO) is analogous to graphene with oxygen moieties. It offers several advantages over graphene, such as a tunable band-gap, facile synthesis and no use of metal catalysts. Due to the monolayer configuration of GO, all of its carbon atoms are readily exposed to the atmosphere and are sensitive to surface perturbations, thus making GO very suitable for liquid-gated field effect transistor (FET) type sensing applications. However, there are two main limitations preventing GO usage in practical FET sensors. It displays (1) variable coverage between fabricated chips and (2) high electrical resistance. In this paper, we overcome these two limitations by using a facile atmospheric-pressure ethanol Chemical Vapor Deposition treatment on top of pre-coated GO (ECVDGO) which decreases the electrical resistivity from 1.99 × 106 Ω square−1 to 4.68 × 103 Ω square−1, and resistivity variation from 1.60 × 106 to 7.72 × 102 Ω square−1; whilst enlarging the surface GO coverage up to 100%. We then demonstrate the ability of the post-treated ECVDGO liquid-gated FET transducer to detect Interleukin-6 which is a multi-functional cytokine involved in regulating the immune function and the acute phase response. The sensing window of the fabricated biosensor to Interleukin-6 is within the physiologically-relevant range, from 4.7 to 300 pg ml−1. The LOD of the sensor based on 3σ is 2.9 pA or 1.53 pg ml−1. This study demonstrates the emerging potential of GO with high manufacturability in liquid-gated FET biosensors for sensitive and label-free detection of bio-molecules.

21 August 2025 in Micro
Verified
Journal Article
Open access
PDF file
JHJoys Alisa Angelina Hutapea
Joys Alisa Angelina Hutapea
YMYosia Gopas Oetama Manik
Yosia Gopas Oetama Manik
SNSun Theo Constan Lotebulo Ndruru
Sun Theo Constan Lotebulo Ndruru
Jingfeng HuangJingfeng Huang
Jingfeng Huang
RGRonn Goei
Ronn Goei
RSRikson Siburian
Rikson Siburian
Graphene, a two-dimensional material with remarkable electrical, thermal, and mechanical properties, has revolutionized the fields of electronics, energy storage, and nanotechnology. This review presents a comprehensive analysis of graphene synthesis techniques, which can be classified into two primary approaches: top-down and bottom-up. Top-down methods, such as mechanical exfoliation, oxidation-reduction, unzipping carbon nanotubes, and liquid-phase exfoliation, are highlighted for their scalability and cost-effectiveness, albeit with challenges in controlling defects and uniformity. In contrast, bottom-up methods, including chemical vapor deposition (CVD), arc discharge, and epitaxial growth on silicon carbide, offer superior structural control and quality but are often constrained by high costs and limited scalability. The interplay between synthesis parameters, material properties, and application requirements is critically examined to provide insights into optimizing graphene production. This review also emphasizes the growing demand for sustainable and environmentally friendly approaches, aligning with the global push for green nanotechnology. By synthesizing current advancements and identifying critical research gaps, this work offers a roadmap for selecting the most suitable synthesis techniques and fostering innovations in scalable and high-quality graphene production. The findings serve as a valuable resource for researchers and industries aiming to harness graphene’s full potential in diverse technological applications.

9 March 2016 in The Analyst
Verified
Journal Article
Open access
PDF file
HCHu Chen
Hu Chen
Jingfeng HuangJingfeng Huang
Jingfeng Huang
APAlagappan Palaniappan
Alagappan Palaniappan
WYWang Yi
Wang Yi
BLBo Liedberg
Bo Liedberg
ATAlfred Tok
Alfred Tok
In this review, recent advances in the development of electronic detection methodologies based on non-antibody recognition elements such as functional liposomes, aptamers and synthetic peptides are discussed.