Static cold storage is generally used to preserve kidney allografts from deceased donors. Hypothermic machine perfusion may improve outcomes after transplantation, but few sufficiently powered prospective studies have addressed this possibility. In this international randomized, controlled trial, we randomly assigned one kidney from 336 consecutive deceased donors to machine perfusion and the other to cold storage. All 672 recipients were followed for 1 year. The primary end point was delayed graft function (requiring dialysis in the first week after transplantation). Secondary end points were the duration of delayed graft function, delayed graft function defined by the rate of the decrease in the serum creatinine level, primary nonfunction, the serum creatinine level and clearance, acute rejection, toxicity of the calcineurin inhibitor, the length of hospital stay, and allograft and patient survival. Machine perfusion significantly reduced the risk of delayed graft function. Delayed graft function developed in 70 patients in the machine-perfusion group versus 89 in the cold-storage group (adjusted odds ratio, 0.57; P=0.01). Machine perfusion also significantly improved the rate of the decrease in the serum creatinine level and reduced the duration of delayed graft function. Machine perfusion was associated with lower serum creatinine levels during the first 2 weeks after transplantation and a reduced risk of graft failure (hazard ratio, 0.52; P=0.03). One-year allograft survival was superior in the machine-perfusion group (94% vs. 90%, P=0.04). No significant differences were observed for the other secondary end points. No serious adverse events were directly attributable to machine perfusion. Hypothermic machine perfusion was associated with a reduced risk of delayed graft function and improved graft survival in the first year after transplantation. (Current Controlled Trials number, ISRCTN83876362.)
Ischemia and reperfusion injury (IRI) is a complex pathophysiological phenomenon, inevitable in kidney transplantation and one of the most important mechanisms for non- or delayed function immediately after transplantation. Long term, it is associated with acute rejection and chronic graft dysfunction due to interstitial fibrosis and tubular atrophy. Recently, more insight has been gained in the underlying molecular pathways and signalling cascades involved, which opens the door to new therapeutic opportunities aiming to reduce IRI and improve graft survival. This review systemically discusses the specific molecular pathways involved in the pathophysiology of IRI and highlights new therapeutic strategies targeting these pathways.
Hypothermic machine perfusion may improve outcome after transplantation of kidneys donated after cardiac death (DCD), but no sufficiently powered prospective studies have been reported. Because organ shortage has led to an increased use of DCD kidneys, we aimed to compare hypothermic machine perfusion with the current standard of static cold storage preservation. Eighty-two kidney pairs from consecutive, controlled DCD donors 16 years or older were included in this randomized controlled trial in Eurotransplant. One kidney was randomly assigned to machine perfusion and the contralateral kidney to static cold storage according to computer-generated lists created by the permuted block method. Kidneys were allocated according to standard rules, with concealment of the preservation method. Primary endpoint was delayed graft function (DGF), defined as dialysis requirement in the first week after transplantation. All 164 recipients were followed until 1 year after transplantation. Machine perfusion reduced the incidence of DGF from 69.5% to 53.7% (adjusted odds ratio: 0.43; 95% confidence interval 0.20–0.89; P = 0.025). DGF was 4 days shorter in recipients of machine-perfused kidneys (P = 0.082). Machine-perfused kidneys had a higher creatinine clearance up to 1 month after transplantation (P = 0.027). One-year graft and patient survival was similar in both groups (93.9% vs 95.1%). Hypothermic machine perfusion was associated with a reduced risk of DGF and better early graft function up to 1 month after transplantation. Routine preservation of DCD kidneys by hypothermic machine perfusion is therefore advisable.
6 March 2013 in American Journal of Transplantation
In contrast to traditional static cold preservation of donor livers, normothermic machine perfusion may reduce preservation injury, improve graft viability and potentially allows ex vivo assessment of graft viability before transplantation. We have studied the feasibility of normothermic machine perfusion in four discarded human donor livers. Normothermic machine perfusion consisted of pressure and temperature controlled pulsatile perfusion of the hepatic artery and continuous portal perfusion for 6 h. Two hollow fiber membrane oxygenators provided oxygenation of the perfusion fluid. Biochemical markers in the perfusion fluid reflected minimal hepatic injury and improving function. Lactate levels decreased to normal values, reflecting active metabolism by the liver (mean lactate 10.0 ± 2.3 mmol/L at 30 min to 2.3 ± 1.2 mmol/L at 6 h). Bile production was observed throughout the 6 h perfusion period (mean rate 8.16 ± 0.65 g/h after the first hour). Histological examination before and after 6 h of perfusion showed well‐preserved liver morphology without signs of additional hepatocellular ischemia, biliary injury or sinusoidal damage. In conclusion, this study shows that normothermic machine perfusion of human donor livers is technically feasible. It allows assessment of graft viability before transplantation, which opens new avenues for organ selection, therapeutic interventions and preconditioning.
Maintaining organ viability after donation until transplantation is critically important for optimal graft function and survival. To date, static cold storage is the most widely used form of preservation in every day clinical practice. Although simple and effective, it is questionable whether this method is able to prevent deterioration of organ quality in the present era with increasing numbers of organs retrieved from older, more marginal, and even non-heart-beating donors. This review describes principles involved in effective preservation and focuses on some basic components and methods of abdominal organ preservation in clinical and experimental transplantation. Concepts and developments to reduce ischemia related injury are discussed, including hypothermic machine perfusion. Despite the fact that hypothermic machine perfusion might be superior to static cold storage preservation, organs are still exposed to hypothermia induced damage. Therefore, recently some groups have pointed at the beneficial effects of normothermic machine perfusion as a new perspective in organ preservation and transplantation.
The purpose of this study was to analyze the possible effects of machine perfusion (MP) versus cold storage (CS) on delayed graft function (DGF) and early graft survival in expanded criteria donor kidneys (ECD). As part of the previously reported international randomized controlled trial 91 consecutive heart‐beating deceased ECDs – defined according to the United Network of Organ Sharing definition – were included in the study. From each donor one kidney was randomized to MP and the contralateral kidney to CS. All recipients were followed for 1 year. The primary endpoint was DGF. Secondary endpoints included primary nonfunction and graft survival. DGF occurred in 27 patients in the CS group (29.7%) and in 20 patients in the MP group (22%). Using the logistic regression model MP significantly reduced the risk of DGF compared with CS (OR 0.460, P = 0.047). The incidence of nonfunction in the CS group (12%) was four times higher than in the MP group (3%) (P = 0.04). One‐year graft survival was significantly higher in machine perfused kidneys compared with cold stored kidneys (92.3% vs. 80.2%, P = 0.02). In the present study, MP preservation clearly reduced the risk of DGF and improved 1‐year graft survival and function in ECD kidneys. (Current Controlled Trials number: ISRCTN83876362).