Yong Wei

Dr. Yong Wei

Yangtze University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2020 in IEEE Access
Verified
Journal Article
Open access
CDChuanhong Du
Chuanhong Du
LLLicai Liu
Licai Liu
SSShuaishuai Shi
Shuaishuai Shi
Yong WeiYong Wei
Yong Wei
In this paper, a low-dimensional hidden nonlinear system is constructed by replacing two linear resistors of a simple integrating circuit with two active memristors. The system was analyzed in detail by using the Lyapunov exponent, 0-1 Test, PoincarC) map, phase diagram, power spectral density diagram, time-domain waveform, and chaotic characteristic diagram. The results show that the system can oscillate by itself under zero initial conditions, and there are various transient transition behaviors, such as from chaos to limit cycle, chaos to quasi-periodic, quasi-periodic to another quasi-periodic transition, quasi-periodic to periodic transition. Besides, these transient processes themselves include 2, 3, 4, and 5 different states respectively, showing multiple transient transitions behavior, which are not reported in the related literature. It is also found that the initial states of these transition states have rich symmetrical attractors and the stable state is multistability. In addition, the global entropy analysis method is adopted to test the universal existence of transient behaviors, which demonstrates that the system has rich nonlinear characteristics. Finally, the memristive circuit verifies the system’s physical feasibility and enriches the application of memristors in circuit theory.

13 August 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Yong WeiYong Wei
Yong Wei
HYHouquan Yu
Houquan Yu
QCQiang Chen
Qiang Chen
GLGuoquan Liu
Guoquan Liu
JCJiefu Chen
Jiefu Chen
This paper presents the research of water holdup detection in oil-water two-phase flows and sensor design based on coplanar microstrip transmission line (also known as coplanar waveguide, CPW). The relationship between the CPW structure/material parameters and electromagnetic wave propagation characteristics was analyzed using conformal transformation method. Adopting double-sided and S-shaped wiring sheet structure, the dynamic range of detection is improved while the structure of the sensor is miniaturized. Therefore, multiple sensors can be arranged on the cross-section of the oil well to form a detection array, which can provide differential information of water holdup on the cross-section of horizontal wells or highly deviated wells and improve the spatial resolution of the measurement. Numerical simulations and experimental results show that the phase shifts of the signal detected by sensors are approximately linearly proportional to the water holdup of the measured fluid, the resolution is up to 3% in the whole range of water holdup from 0% to 100%. This method makes up for the disadvantages of capacitance method and conductance method, which are only effective for low water holdup and high holdup scenarios respectively.

24 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Yong WeiYong Wei
Yong Wei
HYHouquan Yu
Houquan Yu
QCQiang Chen
Qiang Chen
GLGuoquan Liu
Guoquan Liu
CQChaoxian Qi
Chaoxian Qi
JCJiefu Chen
Jiefu Chen
To dynamically monitor the horizontal well, we studied the oil–water two-phase water holdup detection method based on transmission lines, and designed a micro-sensor and a sensor-array water holdup detection tool. We modeled the relationship of the dielectric constant of the transmission line filling medium and the amplitude and phase shift of the electromagnetic wave signal on the transmission line by using the time-domain analysis. We proposed a novel method to measure the water holdup of oil–water mixtures based on the phase shift of signals on the conical spiral transmission line. Furthermore, we simulated and optimized the structural parameters by software simulation, and developed a small conical spiral water holdup sensor suitable for arraying. The single sensor with detection circuits can achieve the full scale (water holdup from 0% to 100%) measurement with resolution better than 3%. On this basis, 12 sensors are used to develop a clock-like sensor-array water holdup detection tool, realizing the array detection of the distribution of the cross-section medium in horizontal wells.

19 July 2024 in IEEE Access
Verified
Journal Article
Open access
XDXiaomei Dai
Xiaomei Dai
Yong WeiYong Wei
Yong Wei
RGRuyi Gan
Ruyi Gan
BWBaojun Wei
Baojun Wei
YXYalin Xiang
Yalin Xiang
PLPing Liu
Ping Liu
Accurate detection of water holdup in oil-water two-phase flow is crucial for optimizing production and improving crude oil recovery. The transmission lines method is currently one of the few effective methods to measure the water holdup of oil-water two-phase flow. However, variations in temperature and mineralization will alter the dielectric constant and conductivity of the oil-water mixture respectively, posing challenges for precise water holdup measurement. The complex nonlinear relationship between these factors limits the prediction range and accuracy of widely used models, such as the BP neural network and Support Vector Machine (SVM). In order to overcome these issues, this paper establishes a multi-sensor oil-water two-phase flow indoor experiment system and studies the complex relationship between the phase shift of sensor signal and influencing factors. On this basis, this paper proposes a combined water holdup prediction model (BO-XGBoost) of Bayesian optimization (BO) algorithm and extreme gradient boosting (XGBoost). The results demonstrate that the XGBoost model outperforms traditional BP neural network and SVM in predicting water holdup across the full range of 0%-100%. The average absolute error of the BO-XGBoost model is only 1.50%. The above research achieves a full-range, high-precision water holdup prediction, providing a new solution for oilfield development and possessing practical engineering significance.

1 March 2019
Verified
Conference Paper
Closed access
Yong WeiYong Wei
Yong Wei
HYHouquan Yu
Houquan Yu
JCJiefu Chen
Jiefu Chen
This paper presents the research of oil-water two-phase water holdup detection method and sensor design based on finite ground coplanar waveguide (abbreviated CPW). The relationship between the structure parameters and material parameters of CPW sensor and electromagnetic wave propagation characteristics was analyzed by conformal transformation method. Adopting double-sided and S-shaped wiring sheet structure, the dynamic range of detection is improved while the structure of the sensor is miniaturized. Numerical simulation and experimental results show that the phase shifts of the signal detected by sensors are approximately linearly proportional to the water holdup of the measured fluid, the resolutions are less than 3% in the whole range of water holdup from 0% to 100%. This method makes up for the disadvantages of capacitance method and conductance method, which are only suitable for low water holdup and high holdup respectively.

1 January 2018 in International Journal of Oil, Gas and Coal Engineering
Verified
Journal Article
Open access
PDF file
CQChen Qiang
Chen Qiang
QMQin Minjun
Qin Minjun
LGLiu Guoquan
Liu Guoquan
LQLi Qingping
Li Qingping
YHYu Houquan
Yu Houquan
FYFang Yu
Fang Yu
In order to realize array measurement of water holdup on oil well section, a capacitance-based sensor with planar inter-digital structure is proposed, an integrated detecting module is designed, which converts the measured capacitance value to periodic signal with corresponding frequency, a circuit which extracts signal from current change of power supply is developed. The experimental result shows the above solution has advantages to minimize size sensor, less connections between sensor and circuit boards, strong anti-interference performance and high definition when water holdup is not above 50%, thereby, it has important reference value for developing array capacitance-based log tool for water holdup measurement.