A fiber Bragg grating (FBG) sensor capable of simultaneous temperature-pressure measurement is presented and experimentally verified, which consists of a diaphragm, a special-shaped bracket, dual FBGs and a protective housing. The principle of simultaneous temperature and pressure measurement with dual FBGs is theoretically illustrated and simulated by finite element analysis. The experimentally investigated results demonstrate that the sensor can be employed to measure temperature and pressure in environments where the temperature ranges from 50 °C to 200 °C and the pressure ranges from 0 MPa to 40 MPa. The temperature sensitivity of the sensor is 31.8 pm/°C with a linear correlation coefficient of 0.9997; the pressure sensitivity is 50.6 pm/MPa, linearity is 0.21%, repeatability and hysteresis error are 0.024% and 0.16% respectively. The sensor exhibits a large measuring range, high temperature resistance, miniaturized structure and easily multiplexed, which allows it for temperature and pressure dual parametric measurements in high temperature and high pressure environments such as oil and gas wells.
A small-sized sensor combined with a diaphragm structure and a lever structure is proposed for application in high temperature and high pressure environments. The feasibility of the structure is verified from both theory and simulation, and the relationship between the change of the Bragg wavelength and the pressure is established. Differential measurements of temperature and pressure are achieved using two FBGs. The experimental data show that the pressure sensitivity of the sensor is 28.86 pm/MPa in the range of 0-30 MPa, and the correlation coefficient is 0.9969. The pressure sensitivity of the improved structure is 29.76 pm/MPa and the correlation coefficient is 0.9999. The sensor’s temperature sensitivity is 32.66 pm/°C in the range of 50-200 °C. The structure can be applied to the measurement of temperature and pressure in oil and gas wells.
To dynamically monitor the horizontal well, we studied the oil–water two-phase water holdup detection method based on transmission lines, and designed a micro-sensor and a sensor-array water holdup detection tool. We modeled the relationship of the dielectric constant of the transmission line filling medium and the amplitude and phase shift of the electromagnetic wave signal on the transmission line by using the time-domain analysis. We proposed a novel method to measure the water holdup of oil–water mixtures based on the phase shift of signals on the conical spiral transmission line. Furthermore, we simulated and optimized the structural parameters by software simulation, and developed a small conical spiral water holdup sensor suitable for arraying. The single sensor with detection circuits can achieve the full scale (water holdup from 0% to 100%) measurement with resolution better than 3%. On this basis, 12 sensors are used to develop a clock-like sensor-array water holdup detection tool, realizing the array detection of the distribution of the cross-section medium in horizontal wells.
Liquid loading in horizontal/inclined gas wells challenges unconventional reservoir development globally. Accurate gas-water velocity and holdup monitoring is crucial for dynamic evaluation. This study simulates flow using a 10-m-long, 120-mm-ID inclined pipe (70°) at Southwest Petroleum University. Air ($\rho_{g}=1.21 \mathrm{~kg} / \mathrm{m}^{3}, \mu_{g}=0.018 \mathrm{mPa} \cdot \mathrm{s}$ ) and water ($\rho_{w}=0.997 \times 10^{3} \mathrm{~kg} / \mathrm{m}^{3}, \mu_{w}=1.002 \mathrm{mPa} \cdot \mathrm{s}$ ) served as media, with total flow rates of 50-500 m3/d and water content of 0%-100%. Capacitance Array Tool (CAT) and Spinner Array Tool (SAT) monitored holdup and velocity under stable conditions, while cameras recorded phase distribution. Flow regimes were primarily slug flow and elongated bubble (EB) flow. Significant probe response variations indicated uneven phase distribution. A torque model for the two-phase flow of gas and water was established, and the slip ratio was introduced to calculate the total flow rate of gas and water in the wellbore on the basis of the response of the array spinners. Validation against 54 experimental datasets showed superior performance over traditional momentum models. Mean relative error (MRE): 11% versus 20%; root mean square error (RMSE): 1.36 versus 2.86; and coefficient of determination ($R^{2}$ ): 0.97 versus 0.90. The model demonstrates effective application for intermittent flows in deviated wells, enabling high-precision production logging interpretation in unconventional gas reservoirs.
In this paper, we proposed a Fiber Bragg Grating (FBG) based on identification of bubble collision and bounce. The FBG target sensor detects the vibration signal resulting from the multiple rebound motions of the bubble after colliding with the target. The tension, diameter, and velocity of the bubbles are related to the frequency and amplitude of the vibration signal. In the test of a single target sensor, the frequency of air bubbles is measured to be within the range of 80-100 Hz which is higher than the frequency of oil bubbles within the range of 0-10 Hz. An annular sensing array based on a 3D printed structure is also demonstrated for measuring the cross-sectional bubbles passing through the pipeline. The proposed sensor introduces a new multiphase sensing principle, paving a way for optical fiber holdup sensor development.