An approach is proposed for removing the wave front curvature introduced by the microscope imaging objective in digital holography, which otherwise hinders the phase contrast imaging at reconstruction planes. The unwanted curvature is compensated by evaluating a correcting wave front at the hologram plane with no need for knowledge of the optical parameters, focal length of the imaging lens, or distances in the setup. Most importantly it is shown that a correction effect can be obtained at all reconstruction planes. Three different methods have been applied to evaluate the correction wave front and the methods are discussed in detail. The proposed approach is demonstrated by applying digital holography as a method of coherent microscopy for imaging amplitude and phase contrast of microstructures.
In microscopy, high magnifications are achievable for investigating micro-objects but the paradigm is that higher is the required magnification, lower is the depth of focus. For an object having a three-dimensional (3D) complex shape only a portion of it appears in good focus to the observer who is essentially looking at a single image plane. Actually, two approaches exist to obtain an extended focused image, both having severe limitations since the first requires mechanical scanning while the other one requires specially designed optics. We demonstrate that an extended focused image of an object can be obtained through digital holography without any mechanical scanning or special optical components. The conceptual novelty of the proposed approach lies in the fact that it is possible to completely exploit the unique feature of DH in extracting all the information content stored in hologram, amplitude and phase, to extend the depth of focus.
A method for controlling the size of amplitude and phase images reconstructed from digital holograms by the Fresnel-transform method is proposed and demonstrated. The method can provide a constant reconstruction pixel width in the reconstructed image plane, independent of the recording and reconstruction distance. The proposed method makes it possible to maintain the size of an object for a sequence of digital holograms recorded at different distances and, therefore, to subtract phase maps for an object recorded at different distances. Furthermore, the method solves the problem of superimposition in multiwavelength digital holography for color display and holographic interferometry applications.
Due to recent breakthroughs, silicon photonics is now the most active discipline within the field of integrated optics and, at the same time, a present reality with commercial products available on the market. Silicon photodiodes are excellent detectors at visible wavelengths, but the development of high-performance photodetectors on silicon CMOS platforms at wavelengths of interest for telecommunications has remained an imperative but unaccomplished task so far. In recent years, however, a number of near-infrared all-silicon photodetectors have been proposed and demonstrated for optical interconnect and power-monitoring applications. In this paper, a review of the state of the art is presented. Devices based on mid-bandgap absorption, surface-state absorption, internal photoemission absorption and two-photon absorption are reported, their working principles elucidated and their performance discussed and compared.
Microfluidic technology has affirmed itself as a powerful tool in medical and biological research by offering the possibility of managing biological samples in tiny channels and chambers. Among the different applications, the use of microfluidics for cell cultures has attracted much interest from scientists worldwide. Traditional cell culture methods need high quantities of samples and reagents that are strongly reduced in miniaturized systems. In addition, the microenvironment is better controlled by scaling down. In this paper, we provide an overview of the aspects related to the design of a novel microfluidic culture chamber, the fabrication approach based on polydimethylsiloxane (PDMS) soft-lithography, and the most critical issues in shrinking the size of the system.
Sperm morphology is regarded as a significant prognostic factor for fertilization, as abnormal sperm structure is one of the most common factors in male infertility. Furthermore, obtaining accurate morphological information is an important issue with strong implications in zoo-technical industries, for example to perform sorting of species X from species Y. A challenging step forward would be the availability of a fast, high-throughput and label-free system for the measurement of physical parameters and visualization of the 3D shape of such biological specimens. Here we show a quantitative imaging approach to estimate simply and quickly the biovolume of sperm cells, combining the optical tweezers technique with digital holography, in a single and integrated set-up for a biotechnology assay process on the lab-on-a-chip scale. This approach can open the way for fast and high-throughput analysis in label-free microfluidic based “cytofluorimeters” and prognostic examination based on sperm morphology, thus allowing advancements in reproductive science.