Abdul Samad

Mr. Abdul Samad

University of Stuttgart
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in Atmospheric Environment
Verified
Journal Article
Open access
ASAbdul Samad
Abdul Samad
SGS. Garuda
S. Garuda
UVU. Vogt
U. Vogt
BYB. Yang
B. Yang

10 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
ASAbdul Samad
Abdul Samad
GCGrecia Carolina Solis Castillo
Grecia Carolina Solis Castillo
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Using low-cost gas sensors for air quality monitoring promises cost effective and convenient measurement systems. Nevertheless, the results obtained have a questionable quality due to different factors that can affect sensor performance. The most discussed ones are relative humidity and air temperature. This investigation aimed to assess the behavior of B4-series low-cost gas sensors from Alphasense for measuring CO, NO, NO2, and O3 for different levels of relative humidity and temperature. These low-cost gas sensors were tested for six relative humidity levels from 10% to 85% with increasing steps of 15% and four temperature levels of 10 °C, 25 °C, 35 °C, and 45 °C against reference instruments in the laboratory. The effect of these parameters on low-cost gas sensors was quantified in laboratory from which a correction algorithm was calculated, which was then applied to the field data. The applied algorithm improved the data quality of the low-cost gas sensors in most of the cases. Additionally, a low-cost dryer was assessed to reduce the influence of these factors on the low-cost gas sensors, which also proved to be suitable to enhance the data quality.

1 August 2020 in Atmospheric Pollution Research
Verified
Journal Article
Open access
ASAbdul Samad
Abdul Samad
UVU. Vogt
U. Vogt
APAgnesh Panta
Agnesh Panta
DUD. Uprety
D. Uprety

21 April 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
DFDiego Alvarez Florez
Diego Alvarez Florez
ICIoannis Chourdakis
Ioannis Chourdakis
UVUlrich Vogt
Ulrich Vogt
A substantial amount of air pollution is emitted from urban sources. Hence, investigating air pollutant dispersion from urban sources is of great importance. The mechanisms influencing air pollutant dispersion also need to be studied thoroughly. Unmanned Aerial Vehicle (UAV)-based systems offer great potential for mobile exploration of air pollutants in the lower atmosphere due to the high maneuverability of multi-rotor UAVs. The aim of this study was to develop an effective UAV system that can perform high-resolution three-dimensional profiling of pollutants, such as particulate matter (PM), ultrafine particles (UFP), black carbon (BC), as well as meteorological parameters, including air temperature, relative humidity, pressure, wind speed, and wind direction. Different experiments were performed to finalize the positioning of the instruments on the UAV platform so as not to destabilize the drone during flight, even when the wind speed is high and during turbulent flight conditions. Another very crucial question is where to place the air inlet of the measurement devices. In addition, field tests were conducted to evaluate the stability of the UAV platform and the in-flight performance of the sensors. This UAV platform was deployed to perform vertical profiles at the University campus in Stuttgart-Vaihingen and in an area near the campus, close to the federal highway B14. The measurement campaign was performed on three days in February 2021, with a maximum flight height of 120 m above ground. The vertical profiles showed that concentrations were higher on the ground due to the proximity to the source and that high wind speeds assisted pollutant dispersion. The horizontal profiles showed that the pollutant concentrations were higher at the roadside and decreased with increasing distance from the road. In conclusion, this UAV platform represented a low-cost, practical, and reliable method for studying the three-dimensional distribution of pollutants near the source.

26 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
FMFreddy Ernesto Melchor Mimiaga
Freddy Ernesto Melchor Mimiaga
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Air pollution in urban areas is a huge concern that demands an efficient air quality control to ensure health quality standards. The hotspots can be located by increasing spatial distribution of ambient air quality monitoring for which the low-cost sensors can be used. However, it is well-known that many factors influence their results. For low-cost Particulate Matter (PM) sensors, high relative humidity can have a significant impact on data quality. In order to eliminate or reduce the impact of high relative humidity on the results obtained from low-cost PM sensors, a low-cost dryer was developed and its effectiveness was investigated. For this purpose, a test chamber was designed, and low-cost PM sensors as well as professional reference devices were installed. A vaporizer regulated the humid conditions in the test chamber. The low-cost dryer heated the sample air with a manually adjustable intensity depending on the voltage. Different voltages were tested to find the optimum one with least energy consumption and maximum drying efficiency. The low-cost PM sensors with and without the low-cost dryer were compared. The experimental results verified that using the low-cost dryer reduced the influence of relative humidity on the low-cost PM sensor results.

1 September 2020 in Urban Climate
Verified
Journal Article
Open access
ASAbdul Samad
Abdul Samad
UVU. Vogt
U. Vogt