Ulrich Vogt

Dr. Ulrich Vogt


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
ASAbdul Samad
Abdul Samad
GCGrecia Carolina Solis Castillo
Grecia Carolina Solis Castillo
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Using low-cost gas sensors for air quality monitoring promises cost effective and convenient measurement systems. Nevertheless, the results obtained have a questionable quality due to different factors that can affect sensor performance. The most discussed ones are relative humidity and air temperature. This investigation aimed to assess the behavior of B4-series low-cost gas sensors from Alphasense for measuring CO, NO, NO2, and O3 for different levels of relative humidity and temperature. These low-cost gas sensors were tested for six relative humidity levels from 10% to 85% with increasing steps of 15% and four temperature levels of 10 °C, 25 °C, 35 °C, and 45 °C against reference instruments in the laboratory. The effect of these parameters on low-cost gas sensors was quantified in laboratory from which a correction algorithm was calculated, which was then applied to the field data. The applied algorithm improved the data quality of the low-cost gas sensors in most of the cases. Additionally, a low-cost dryer was assessed to reduce the influence of these factors on the low-cost gas sensors, which also proved to be suitable to enhance the data quality.

8 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JJJanani Venkatraman Jagatha
Janani Venkatraman Jagatha
AKAndré Klausnitzer
André Klausnitzer
MCMiriam Chacón-Mateos
Miriam Chacón-Mateos
BLBernd Laquai
Bernd Laquai
ENEvert Nieuwkoop
Evert Nieuwkoop
CSChristoph Schneider
Christoph Schneider
Over the last decade, manufacturers have come forth with cost-effective sensors for measuring ambient and indoor particulate matter concentration. What these sensors make up for in cost efficiency, they lack in reliability of the measured data due to their sensitivities to temperature and relative humidity. These weaknesses are especially evident when it comes to portable or mobile measurement setups. In recent years many studies have been conducted to assess the possibilities and limitations of these sensors, however mostly restricted to stationary measurements. This study reviews the published literature until 2020 on cost-effective sensors, summarizes the recommendations of experts in the field based on their experiences, and outlines the quantile-mapping methodology to calibrate low-cost sensors in mobile applications. Compared to the commonly used linear regression method, quantile mapping retains the spatial characteristics of the measurements, although a common correction factor cannot be determined. We conclude that quantile mapping can be a useful calibration methodology for mobile measurements given a well-elaborated measurement plan assures providing the necessary data.

21 April 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
DFDiego Alvarez Florez
Diego Alvarez Florez
ICIoannis Chourdakis
Ioannis Chourdakis
UVUlrich Vogt
Ulrich Vogt
A substantial amount of air pollution is emitted from urban sources. Hence, investigating air pollutant dispersion from urban sources is of great importance. The mechanisms influencing air pollutant dispersion also need to be studied thoroughly. Unmanned Aerial Vehicle (UAV)-based systems offer great potential for mobile exploration of air pollutants in the lower atmosphere due to the high maneuverability of multi-rotor UAVs. The aim of this study was to develop an effective UAV system that can perform high-resolution three-dimensional profiling of pollutants, such as particulate matter (PM), ultrafine particles (UFP), black carbon (BC), as well as meteorological parameters, including air temperature, relative humidity, pressure, wind speed, and wind direction. Different experiments were performed to finalize the positioning of the instruments on the UAV platform so as not to destabilize the drone during flight, even when the wind speed is high and during turbulent flight conditions. Another very crucial question is where to place the air inlet of the measurement devices. In addition, field tests were conducted to evaluate the stability of the UAV platform and the in-flight performance of the sensors. This UAV platform was deployed to perform vertical profiles at the University campus in Stuttgart-Vaihingen and in an area near the campus, close to the federal highway B14. The measurement campaign was performed on three days in February 2021, with a maximum flight height of 120 m above ground. The vertical profiles showed that concentrations were higher on the ground due to the proximity to the source and that high wind speeds assisted pollutant dispersion. The horizontal profiles showed that the pollutant concentrations were higher at the roadside and decreased with increasing distance from the road. In conclusion, this UAV platform represented a low-cost, practical, and reliable method for studying the three-dimensional distribution of pollutants near the source.

21 May 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
FDFlorencia M. R. Diaz
Florencia M. R. Diaz
Anwar  KhanAnwar Khan
Anwar Khan
BSBeth M. A. Shallcross
Beth M. A. Shallcross
ESEsther D. G. Shallcross
Esther D. G. Shallcross
UVUlrich Vogt
Ulrich Vogt
Dudley E. ShallcrossDudley E. Shallcross
Dudley E. Shallcross
Previous work regarding the behaviour of ozone surface concentrations over many years in the United Kingdom had predicted that the frequency and severity of ozone episodes would become less marked in the future as a response to environmental regulations. The aim of this study is to extend these studies and compare the results with their predictions. The ozone data of 13 rural and six urban sites in the UK collected from the Department for Environment, Food and Rural Affairs over a period from 1992 to mid-2019 were used to investigate this behaviour. The yearly ozone exceedances (the number of hours that the ozone concentration exceeded the 50 ppbv limit) in the United Kingdom were found to have decreased over the last 30 years regardless of the type of site (rural or urban), showing that the adopted emission controls have so far been successful in the abatement of pollutant emissions. In the past three decades, the highest numbers of exceedances were reached in May regardless of the type of site. Furthermore, these episodes have become less frequent and less severe in recent years. In fact, the number of hours of exceedance is lower than that in previous decades, and it is almost constant throughout the week.

26 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
FMFreddy Ernesto Melchor Mimiaga
Freddy Ernesto Melchor Mimiaga
BLBernd Laquai
Bernd Laquai
UVUlrich Vogt
Ulrich Vogt
Air pollution in urban areas is a huge concern that demands an efficient air quality control to ensure health quality standards. The hotspots can be located by increasing spatial distribution of ambient air quality monitoring for which the low-cost sensors can be used. However, it is well-known that many factors influence their results. For low-cost Particulate Matter (PM) sensors, high relative humidity can have a significant impact on data quality. In order to eliminate or reduce the impact of high relative humidity on the results obtained from low-cost PM sensors, a low-cost dryer was developed and its effectiveness was investigated. For this purpose, a test chamber was designed, and low-cost PM sensors as well as professional reference devices were installed. A vaporizer regulated the humid conditions in the test chamber. The low-cost dryer heated the sample air with a manually adjustable intensity depending on the voltage. Different voltages were tested to find the optimum one with least energy consumption and maximum drying efficiency. The low-cost PM sensors with and without the low-cost dryer were compared. The experimental results verified that using the low-cost dryer reduced the influence of relative humidity on the low-cost PM sensor results.

1 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ASAbdul Samad
Abdul Samad
JKJoschka Kieser
Joschka Kieser
ICIoannis Chourdakis
Ioannis Chourdakis
UVUlrich Vogt
Ulrich Vogt
Conventional air quality monitoring has been traditionally carried out in a few fixed places with expensive measuring equipment. This results in sparse spatial air quality data, which do not represent the real air quality of an entire area, e.g., when hot spots are missing. To obtain air quality data with higher spatial and temporal resolution, this research focused on developing a low-cost network of cloud-based air quality measurement platforms. These platforms should be able to measure air quality parameters including particulate matter (PM10, PM2.5, PM1) as well as gases like NO, NO2, O3, and CO, air temperature, and relative humidity. These parameters were measured every second and transmitted to a cloud server every minute on average. The platform developed during this research used one main computer to read the sensor data, process it, and store it in the cloud. Three prototypes were tested in the field: two of them at a busy traffic site in Stuttgart, Marienplatz and one at a remote site, Ötisheim, where measurements were performed near busy railroad tracks. The developed platform had around 1500 € in materials costs for one Air Quality Sensor Node and proved to be robust during the measurement phase. The notion of employing a Proportional–Integral–Derivative (PID) controller for the efficient working of a dryer that is used to reduce the negative effect of meteorological parameters such as air temperature and relative humidity on the measurement results was also pursued. This is seen as one way to improve the quality of data captured by low-cost sensors.