Aleksandar Radu

Dr. Aleksandar Radu

Chemistry School of Chemical and Physical Sciences, Lennard-Jones Building room 1.06, Keele University, Keele, Staffs ST5 5BG, UK
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JCJittima Choosang
Jittima Choosang
ANApon Numnuam
Apon Numnuam
PTPanote Thavarungkul
Panote Thavarungkul
PKProespichaya Kanatharana
Proespichaya Kanatharana
Tanja RaduTanja Radu
Tanja Radu
Aleksandar RaduAleksandar Radu
Aleksandar Radu
Simple, robust, and low-cost nitrate- and ammonium-selective electrodes were made using substrate prepared from household materials. We explored phosphonium-based ILs and poly (methyl methacrylate)/poly(decyl methacrylate)(MMA-DMA) copolymer as matrix materials alternative to classical PVC-based membranes. IL-based membranes showed suitability only for nitrate-selective electrode exhibiting linear concentration range between 5.0 × 10−6 and 2.5 × 10−3 M with a detection limit of 5.5 × 10−7 M. On the other hand, MMA-DMA—based membranes showed suitability for both ammonium- and nitrate-selective electrodes, and were successfully applied to detect NO3− and NH4+ in water and soil samples. The proposed ISEs exhibited near-Nernstian potentiometric responses to NO3− and NH4+ with the linear range concentration between 5.0 × 10−5 and 5.0 × 10−2 M (LOD = 11.3 µM) and 5.0 × 10−6 and 1.0 × 10−3 M (LOD = 1.2 µM), respectively. The power of ISEs to detect NO3− and NH4+ in water and soils was tested by comparison with traditional, portable colorimetric techniques. Procedures required for analysis by each technique from the perspective of a non-trained person (e.g., farmer) and the convenience of the use on the field are compared and contrasted.

1 January 2013 in Journal of the Serbian Chemical Society
Verified
Journal Article
Open access
PDF file
Aleksandar RaduAleksandar Radu
Aleksandar Radu
Tanja RaduTanja Radu
Tanja Radu
CMChristina M McGraw
Christina M McGraw
PDPeter Dillingham
Peter Dillingham
SASalzitsa Anastasova-Ivanova
Salzitsa Anastasova-Ivanova
Dermot DiamondDermot Diamond
Dermot Diamond
An overview is given dealing with application of ion-selective electrodes (ISEs) in environmental analysis. ISEs are placed into the context of the trend of development of sensors for extensive and frequent monitoring. Discussed are the issues such as sensing platforms and their mass-production, improvement of precision, diagnostic of sensor?s functionality, and development of reference electrodes and several examples of real-life application of ISEs in environmental analysis are given. The main emphasis of this article is directed towards summarizing recent of authors? results during the past several years.

17 December 2019 in ACS Sensors
Verified
Journal Article
Closed access
PDPeter Dillingham
Peter Dillingham
BABasim S. O. Alsaedi
Basim S. O. Alsaedi
SGSergio Granados-Focil
Sergio Granados-Focil
Aleksandar RaduAleksandar Radu
Aleksandar Radu
CMChristina M. McGraw
Christina M. McGraw

11 April 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
LMLukasz Mendecki
Lukasz Mendecki
XCXiaorui Chen
Xiaorui Chen
NCNicole Callan
Nicole Callan
DTDavid F. Thompson
David F. Thompson
BSBenjamin Schazmann
Benjamin Schazmann
Aleksandar RaduAleksandar Radu
Aleksandar Radu

13 July 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
LMLukasz Mendecki
Lukasz Mendecki
TFTolulope Fayose
Tolulope Fayose
KSKelli A. Stockmal
Kelli A. Stockmal
JWJia Wei
Jia Wei
SGSergio Granados-Focil
Sergio Granados-Focil
Aleksandar RaduAleksandar Radu
Aleksandar Radu

5 December 2020 in Analytical Science Advances
Verified
Journal Article
Open access
PDF file
TFTolulope Fayose
Tolulope Fayose
ETEllen Thomas
Ellen Thomas
Tanja RaduTanja Radu
Tanja Radu
PDPeter Dillingham
Peter Dillingham
SUSami Ullah
Sami Ullah
Aleksandar RaduAleksandar Radu
Aleksandar Radu
In this paper, we demonstrate the suitability, sensitivity, and precision of low‐cost and easy‐to‐use ion‐selective electrodes (ISEs) for concurrent detection of NH4+ and NO3‐ in soil and water by technical and non‐technical end‐users to enable efficient soil and water management exposed to chronic reactive nitrogen loading. We developed a simplified methodology for sample preparation followed by the demonstration of an analytical methodology resulting in improvements of sensitivity and precision of ISEs. Herein, we compared and contrasted ISEs with traditional laboratory‐based technique such as Flow Injection Analysis (FIA) and portable colorimetric assay followed by comparisons of linear regression and Bayesian nonlinear calibration approaches applied on both direct potentiometry and standard addition modes of analysis in terms of in‐field applications and improvement of sensitivity and precision. The ISEs were validated for sensing on a range of ambient soil and water samples representing a range of NH4+ and NO3‐ concentrations from pristine to excessive saturation conditions. Herein developed methodology showed excellent agreement with lab‐based and portable analytical techniques while demonstrating improvements in precision and sensitivity analysis illustrated by a decrease in confidence intervals by 50‐60%. We also demonstrated the utilization of the entire ISE response curve thus removing the biases originating from linear approximation which is often currently employed. Therefore, we show that ISEs are robust yet low cost and an easy to use technology that can enable high‐frequency measurement of mineral N and help to improve our understanding of N transformation processes as influenced by soil management, fertilization, land use, and climate change.