In recent decades, the biomedical applications of mesenchymal stem cells (MSCs) have attracted increasing attention. MSCs are easily extracted from the bone marrow, fat, and synovium, and differentiate into various cell lineages according to the requirements of specific biomedical applications. As MSCs do not express significant histocompatibility complexes and immune stimulating molecules, they are not detected by immune surveillance and do not lead to graft rejection after transplantation. These properties make them competent biomedical candidates, especially in tissue engineering. We present a brief overview of MSC extraction methods and subsequent potential for differentiation, and a comprehensive overview of their preclinical and clinical applications in regenerative medicine, and discuss future challenges.
Repairing articular osteochondral defects present considerable challenges in self‐repair due to the complex tissue structure and low proliferation of chondrocytes. Conventional clinical therapies have not shown significant efficacy, including microfracture, autologous/allograft osteochondral transplantation, and cell‐based techniques. Therefore, tissue engineering has been widely explored in repairing osteochondral defects by leveraging the natural regenerative potential of biomaterials to control cell functions. However, osteochondral tissue is a gradient structure with a smooth transition from the cartilage to subchondral bone, involving changes in chondrocyte morphologies and phenotypes, extracellular matrix components, collagen type and orientation, and cytokines. Bioinspired scaffolds have been developed by simulating gradient characteristics in heterogeneous tissues, such as the pores, components, and osteochondrogenesis‐inducing factors, to satisfy the anisotropic features of osteochondral matrices. Bioinspired gradient scaffolds repair osteochondral defects by altering the microenvironments of cell growth to induce osteochondrogenesis and promote the formation of osteochondral interfaces compared with homogeneous scaffolds. This review outlines the meaningful strategies for repairing osteochondral defects by tissue engineering based on gradient scaffolds and predicts the pros and cons of prospective translation into clinical practice.
30 September 2022 in Frontiers in Bioengineering and Biotechnology
Meniscal injuries caused by trauma, degeneration, osteoarthritis, or other diseases always result in severe joint pain and motor dysfunction. Due to the unique anatomy of the human meniscus, the damaged meniscus lacks the ability to repair itself. Moreover, current clinical treatments for meniscal injuries, including meniscal suturing or resection, have significant limitations and drawbacks. With developments in tissue engineering, biopolymer scaffolds have shown promise in meniscal injury repair. They act as templates for tissue repair and regeneration, interacting with surrounding cells and providing structural support for newly formed meniscal tissue. Biomaterials offer tremendous advantages in terms of biocompatibility, bioactivity, and modifiable mechanical and degradation kinetics. In this study, the preparation and composition of meniscal biopolymer scaffolds, as well as their properties, are summarized. The current status of research and future research prospects for meniscal biopolymer scaffolds are reviewed in terms of collagen, silk, hyaluronic acid, chitosan, and extracellular matrix (ECM) materials. Overall, such a comprehensive summary provides constructive suggestions for the development of meniscal biopolymer scaffolds in tissue engineering.
9 February 2022 in Frontiers in Bioengineering and Biotechnology
Spinal cord injury (SCI) is a complex neurological condition caused by trauma, inflammation, and other diseases, which often leads to permanent changes in strength and sensory function below the injured site. Changes in the microenvironment and secondary injuries continue to pose challenges for nerve repair and recovery after SCI. Recently, there has been progress in the treatment of SCI with the use of scaffolds for neural tissue engineering. Polymeric fibers fabricated by electrospinning have been increasingly used in SCI therapy owing to their biocompatibility, complex porous structure, high porosity, and large specific surface area. Polymer fibers simulate natural extracellular matrix of the nerve fiber and guide axon growth. Moreover, multiple channels of polymer fiber simulate the bundle of nerves. Polymer fibers with porous structure can be used as carriers loaded with drugs, nerve growth factors and cells. As conductive fibers, polymer fibers have electrical stimulation of nerve function. This paper reviews the fabrication, characterization, and application in SCI therapy of polymeric fibers, as well as potential challenges and future perspectives regarding their application.
19 July 2023 in Medcomm – Biomaterials and Applications
Although cartilage regeneration is a continuously changing, complex process, most studies on cartilage tissue regeneration have focused on specific stages, thereby promoting regeneration in only a limited period rather than over the entire repair process. The ideal adaptive scaffolds for cartilage tissue engineering should exhibit dynamic and spatiotemporally controlled evolution according to the physiological microenvironments during each phase of cartilage repair. Moreover, scaffolds should have a specific feedback regulation capability, including long‐term feedback for the controlled delivery of multiple factors, which would better meet the requirements of cartilage regeneration. Adaptive scaffolds matching the whole evolving stages of cartilage repair are still under exploration. This review highlights the development of dynamically adaptive scaffolds to provide the appropriate microenvironments for cartilage regeneration, including scaffolds that manipulate the immune microenvironments from the inflammation stage to the regeneration stage, scaffolds that release cytokines on demand across several stages, and scaffolds that adapt according to the mechanical properties of extracellular matrices over time, and also discusses the future challenges and development directions of adaptive scaffolds in cartilage tissue regeneration. This understanding is expected to inspire the application of adaptive scaffolds for cartilage repair.
Background: Modular prosthesis fracture, especially distal femoral fracture, is a rare complication of total hip arthroplasty (THA). However, it is catastrophic, and may have a serious impact on the patients. A distal femoral prosthesis fracture in a patient with developmental dysplasia of the hip (DDH) with nonunion at the subtrochanteric osteotomy site has not yet been reported in any literature. This report presents the first such case, with a purpose of analyzing the causes of modular prosthesis fractures and nonunion of the osteotomy area, so as to provide orthopedic surgeons with experience and lessons. Case presentation: We report the case of a 52-year-old woman with the distal femoral prosthesis fracture after THA and subtrochanteric osteotomy for Crowe type IV DDH. The patient had severe pain in the left thigh and her activities were limited. Plain radiographs revealed fracture of the left distal femoral prosthesis and nonunion in the subtrochanteric osteotomy region of the left femur. After a revision of the THA, the patient’s symptoms were resolved. Conclusions: A prosthesis fracture combined with nonunion at the subtrochanteric osteotomy site is a rare complication. Modular THA combined with a subtrochanteric osteotomy in the treatment of Crowe type IV DDH should reduce the damage to blood supply and avoid further nonunion of the osteotomy area, which may otherwise lead to modular prosthesis fractures. A detailed preoperative plan and suitable rehabilitation program may help minimize the occurrence of subtrochanteric osteotomy nonunion and reduce complications, including femoral prosthesis fractures, in patients with DDH.