A sensitive and flexible detection method for organophosphorus pesticides (OPs) detection is a crucial request to avoid their further expanded pollution. Herein, an acetylcholinesterase (AChE) electrochemical sensor, based on the co-modification of ZIF-8 and graphene (GR), was constructed for the detection of OPs. ZIF-8/GR composite can provide a stable and biocompatible environment for the loading of AChE and can accelerate the chemical reaction on the electrode surface. After optimization, the linear detection range of the constructed AChE-CS/GR/ZIF-8/GCE sensor for ICP was 0.5–100 ng/mL (1.73–345.7 nM), and the limit of detection was 0.18 ng/mL (0.62 nM). Moreover, high sensitivity and high specificity of the sensor were also achieved in actual cabbage and tap water samples. Therefore, it has great potential for the application of organophosphorus pesticide residue analysis.
The rapid detection of organophosphorus (OP) compounds is crucial for safeguarding human health and ensuring food safety. This study presents a novel wearable electrochemical biosensor that integrates miniaturized screen-printed electrodes with wearable devices to achieve real-time, on-site OP detection. The biosensor was fabricated by constructing a screen-printed carbon electrode (SPCE) on a thermoplastic polyurethane (TPU) substrate, sequentially modified with graphene (GR), gold nanoparticles (AuNPs), and organophosphorus hydrolase (OPH), and finally encapsulated with Nafion. This SPCE/GR/AuNPs/OPH/Nafion configuration yields a highly flexible and portable device. The detection principle relies on the enzymatic hydrolysis of methyl paraoxon (MPOX) by OPH, generating p-nitrophenol (PNP), which is quantitatively measured via square wave voltammetry (SWV). The sensor exhibits a broad linear detection range (30–400 μM) with a strong linear correlation (R2 = 0.995) and a low detection limit (0.321 μM). It demonstrates excellent selectivity against common interfering substances, including urea, sucrose, and various metal ions. Application to real-world samples such as cabbage and tap water yielded high recoveries (107.2% for cabbage and 101.2% for tap water), with relative standard deviations (RSDs) below 8%. Furthermore, the biosensor maintains robust flexibility and mechanical resilience, with less than 5% signal loss after 100 bending cycles, confirming its suitability for wearable applications and reliable operation under mechanical stress. This innovative, flexible electrochemical biosensor provides a powerful and reliable platform for rapid OP detection, particularly in complex testing environments.