Dobroslawa Kaczorek

Dr. Dobroslawa Kaczorek


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Małgorzata BasińskaMałgorzata Basińska
Małgorzata Basińska
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
HKHalina Koczyk
Halina Koczyk
The energy-saving requirements for most buildings focus on improving the insulation and airtightness of a building’s envelope. In this paper, the authors have investigated the effect of additional internal insulation on energy consumption for heating and cooling in a residential building. Energy performance analyses were conducted for buildings with four internal thermal insulation systems in three locations using the WUFI Plus software. The Global Cost Method and Simply Pay Back Time have been used to assess and compare the economic viability of the retrofit systems. The results show that, in relation to energy, retrofitting with internal wall insulation can be an alternative to traditional external insulation. The assessment of internal insulation for low-energy buildings, however, cannot be conducted based on economic criteria. The usual approach of Simply Pay Back Time has exceptionally long payback time, which is unacceptable. In turn, the Global Cost Method, can only be used to compare the applied materials. With high investment costs, thermo-modernization improvements do not contribute to significant savings. The conditions of thermal comfort and the analysis of temperature and steam pressure play a decisive role in assessing this type of solution.

19 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
Małgorzata BasińskaMałgorzata Basińska
Małgorzata Basińska
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
HKHalina Koczyk
Halina Koczyk
This study presents a multi-objective optimisation of building thermo-modernisation for multi-family buildings. The applied model has considered alternative solutions for insulation materials, with different thicknesses and different types of windows. The weighted sum method was applied to find a solution considering the minimisation of global cost, primary energy ratio and CO2 emissions. The solutions were compared for a building equipped with natural ventilation, and with mechanical supply—exhaust ventilation. In reference to the two considered types of ventilation, we analysed how the modification of an insulation thickness, its type and the type of installed windows, can be converted into individual evaluation criteria. The weights of the considered criteria were changed; however, this had no influence on the optimal solution. If the aim is to achieve the standards of zero-energy buildings, natural ventilation cannot be applied, despite the high value of thermal insulation of the building envelopes. Alternative solutions exist for buildings with natural ventilation and mechanical ventilation with heat recovery, where the primary energy ratio is the same for both, but the global costs are different. The additional energy and environmental input for the production of materials and elements to be replaced are insignificant in comparison to the savings brought about by thermo-modernisation.

20 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
In this paper, a series of experiments assessing the moisture buffer value (MBV) of four internal wall assembly samples made from hygroscopic materials was performed. A modified Nordtest protocol was used. Moisture buffer values of all the investigated wall assemblies, with varying moisture loads in the range of 50% to 80%, showed a moderate moisture buffer value (MBV: 0.5–1.0 (g·m−2·%RH−1)). The results showed that in a wall assembly where the MBV of the whole assembly is lower than the MBV of the outer layers, the moisture-buffering capacity of the inner layer is untapped. Outer layers affect inner layers by changing their moisture-buffering capacity, which in turn changes the overall performance of the whole assembly. In addition, it was observed that if the penetration depth value of the outer layer is greater than its thickness, vapour reaches into the deeper layer and wall assemblies made of layers with materials characterized by a lower value of penetration depth reach steady state more slowly. The WUFI Pro tool was used to compare the simulated and experimental results. Despite the discrepancies between these results, it offers a simplified method, helping designers make decisions about which materials to choose to improve the moisture-buffering effect.

20 January 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
MBMałgorzata Basińska
Małgorzata Basińska
HKHalina Koczyk
Halina Koczyk

24 December 2013 in JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT
Verified
Journal Article
Closed access
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
HKHalina Koczyk
Halina Koczyk
This paper presents studies on thermal energy efficiency of heating surface at an open space according to structural solutions and climatic conditions. Numerical simulation research was conducted to assess three different types of heating surfaces at an open space over chosen period of time in real weather conditions. Performance parameters such as surface temperature, supply temperature and efficiency of heating surface relative to constructional designs and model of control strategy used were analysed. The number, thickness and type of material layers beneath ground level were modified. The distance between heating pipes and their diameters were kept constant. The carried out analyses show that the used solutions can lead to significant differences in the performance and consequently in the energy efficiency of the heating system for open spaces.

1 November 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
DKDobroslawa Kaczorek
Dobroslawa Kaczorek
Massive walls exposed to external climate are characterized by low levels of thermal insulation. Unfortunately in many cases, due to the historic character of the building, the only possible way to improve their thermal insulation is the use of internal insulation. However, such solutions are associated with the risk of frost damage, mould growth or interstitial condensation. Calculations regarding the occurrence of these risks require complex calculation methods. Therefore, in the present work, the evaluation of the hygrothermal behavior of the internally insulated solid brick wall was performed based on the numerical simulations using the program WUFI Pro. Various material solutions of internal insulations, based on both synthetic and natural materials, were compared. The focus was on a particularly sensitive interface between the insulation and the original wall