Piero Pinamonti

Dr. Piero Pinamonti

Polytechnic Department of Engineering and Architecture, University of Udine, 33100 Udine, Italy

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2013 in Journal of Energy Resources Technology
Verified
Journal Article
Closed access
PDF file
DMDiego Micheli
Diego Micheli
Piero PinamontiPiero Pinamonti
Piero Pinamonti
MRM. Reini
M. Reini
RTR. Taccani
R. Taccani

29 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
Melchiorre CasisiMelchiorre Casisi
Melchiorre Casisi
SCStefano Costanzo
Stefano Costanzo
Piero PinamontiPiero Pinamonti
Piero Pinamonti
Mauro ReiniMauro Reini
Mauro Reini
The paper deals with the modeling and optimization of an integrated multi-component energy system. On-off operation and presence-absence of components must be described by means of binary decision variables, besides equality and inequality constraints; furthermore, the synthesis and the operation of the energy system should be optimized at the same time. In this paper a hierarchical optimization strategy is used, adopting a genetic algorithm in the higher optimization level, to choose the main binary decision variables, whilst a MILP algorithm is used in the lower level, to choose the optimal operation of the system and to supply the merit function to the genetic algorithm. The method is then applied to a distributed generation system, which has to be designed for a set of users located in the center of a small town in the North-East of Italy. The results show the advantage of distributed cogeneration, when the optimal synthesis and operation of the whole system are adopted, and significant reduction in the computing time by using the proposed two-level optimization procedure.

2 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Melchiorre CasisiMelchiorre Casisi
Melchiorre Casisi
Piero PinamontiPiero Pinamonti
Piero Pinamonti
Mauro ReiniMauro Reini
Mauro Reini
The study examines the option of adding a bottom Organic Rankine Cycle (ORC) for energy recovery from an internal combustion engine (ICE) for ship propulsion. In fact, energy recovery from the exhaust gas normally rejected to the atmosphere and eventually from the cooling water circuit (usually rejected to the sea) can significantly reduce the fuel consumption of a naval ICE during its operation. In the paper, different possible bottom ORC configurations are considered and simulated using the Aspen® code. Different working fluids are taken into account, jointly with regenerative and two-temperature levels designs. The energy recovery allowed by each solution is evaluated for different engine load, allowing the identification of the most suitable ORC configuration. For the selected case, the preliminary design of the main heat exchangers is carried out and the off-design performance of the whole combined propulsion plant (ICE + ORC) is evaluated, leading to a preliminary analysis of cost saving during normal ship operation. The results of this analysis show an increase in power output of about 10% and an expected Payback Time of less than 6 years.

2 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PGPaolo Gnes
Paolo Gnes
Piero PinamontiPiero Pinamonti
Piero Pinamonti
Mauro ReiniMauro Reini
Mauro Reini
In recent years, ship builders and owners have to face a great effort to develop new design and management methodologies that lead to a reduction in consumption and emissions during the operation of the fleet. In the present study, the optimization of an on-board energy system of a large cruise ship is performed, both in terms of energy and of the overall dimensions of the system, while respecting the environmental constraint. In the simulation, a variable number of identical Organic Rankine Cycle (ORC)/Stirling units is considered as an energy recovery system, bottoming the main internal combustion engines, possibly integrating with the installation of photovoltaic panels, solar thermal collectors, absorption refrigeration machines and thermal storages. The optimization takes into account the effective optimal management of the energy system, which is different according to the different design choices of the energy recovery system. Two typical cruises are considered (summer and winter). To reduce the computational effort for the solution of the problem, a bi-level strategy has been developed, which prescribes managing the binary choice variables expressing the existence or not of the components by means of an evolutionary algorithm, while all the remaining choice variables are obtained by a mixed-integer linear programming model of the system (MILP) algorithm. The entire procedure can be defined within the commercial software modeFRONTIER®.

27 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Melchiorre CasisiMelchiorre Casisi
Melchiorre Casisi
DBDario Buoro
Dario Buoro
Piero PinamontiPiero Pinamonti
Piero Pinamonti
Mauro ReiniMauro Reini
Mauro Reini
The paper proposes a comparison of different district integration options for a distributed generation system for heating and cooling in an urban area. The system considered includes several production units located close to the users, a central unit and the district heating and cooling network which can connect all the users to each other and to a central unit, where a cogeneration system and a solar plant can be placed. Thus, each user can be regarded as isolated from the others, satisfying its energy needs by means of an autonomous production unit. Alternatively, it can be connected to the others through the district heating and cooling network. When a district heating and cooling network is included in the design option the synthesis-design and operation problems cannot be solved separately, because the energy to be produced by each production site is not known in advance, as the flows through the district heating and cooling network are not defined. This paper uses a mixed integer linear programming (MILP) methodology for the multi-objective optimization of the distributed generation energy system, considering the total annual cost for owning, operating and maintaining the whole system as the economic objective function, while the total annual CO2 emissions as the environmental objective function. The energy system is optimized for different district integration option, in order to understand how they affect the optimal solutions compared with both the environmental and economic objects.

1 January 2002
Verified
Conference Paper
Closed access
PDF file
FBFranco Blanchini
Franco Blanchini
PGPietro Giannattasio
Pietro Giannattasio
DMDiego Micheli
Diego Micheli
Piero PinamontiPiero Pinamonti
Piero Pinamonti
The present paper deals with several problems arising in the stabilisation of surge in compression systems. From a theoretical standpoint the system requires a high gain type controller to be stabilised. On the other hand, the real system is affected by persistent measurement noise whose negative effect on stability is strongly amplified by the high gain. Therefore, a suitable filtering of the system output is necessarily required. The bandwidth of the filter is subject to opposite constraints: if it is too large it affects the attenuation property; if it is too narrow, the large phase-lag introduced at low frequencies may compromise the system stabilisation, which requires a fast actuator reaction. This paper analyses all these aspects concurring in the stabilisation problem and the consequent trade-off in the control design. The results of experimental and numerical studies are provided with reference to the active control of surge in a multistage centrifugal compressor.