Jujie Ren

Jujie Ren


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
CZCong Zhang
Cong Zhang
JRJujie Ren
Jujie Ren
YXYifei Xing
Yifei Xing
MCMin Cui
Min Cui
NLNa Li
Na Li
MLMeng Li
Meng Li

22 July 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
CZCong Zhang
Cong Zhang
LFLimin Fan
Limin Fan
JRJujie Ren
Jujie Ren
MCMin Cui
Min Cui
NLNa Li
Na Li
XJXueping Ji
Xueping Ji

12 April 2023 in Molecules
Verified
Journal Article
Open access
PDF file
NLNa Li
Na Li
HZHongyue Zhang
Hongyue Zhang
MCMin Cui
Min Cui
JRJujie Ren
Jujie Ren
JHJingru Huang
Jingru Huang
CZCong Zhang
Cong Zhang
In this study, the preparation of covalent polyoxometalate organic frameworks (CPOFs) is introduced using the idea of polyoxometalate and covalent organic frameworks. Firstly, the prepared polyoxometalate was functionalized with an amine group (NH2-POM-NH2), and then the CPOFs were prepared by a solvothermal Schiff base reaction with NH2-POM-NH2 and 2,4,6-trihydroxybenzene-1,3,5-tricarbaldehyde (Tp) as monomers. After the incorporation of PtNPs and MWCNTs into the CPOFs material, the PtNPs-CPOFs-MWCNTs nanocomposites, which possess excellent catalytic activity and electrical conductivity, were formed and utilized as new electrode materials for the electrochemical thymol sensors. The obtained PtNPs-CPOFs-MWCNTs composite exhibits excellent activity toward thymol, which is attributable to its large special surface area, good conductivity and the synergistic catalysis of each component. Under optimal experimental conditions, the sensor presented a good electrochemical response to thymol. The sensor shows two good linear relationships between the current and thymol concentration in the range of 2–65 μM (R2 = 0.996) and 65–810 μM (R2 = 0.997), with the corresponding sensitivity of 72.7 μA mM−1 and 30.5 μA mM−1, respectively. Additionally, the limit of detection (LOD) was calculated to be 0.2 μM (S/N = 3). At the same time, the prepared thymol electrochemical sensor revealed superior stability and selectivity. The constructed PtNPs-CPOFs-MWCNT electrochemical sensor is the first example of thymol detection.

8 February 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MCMin Cui
Min Cui
HZHaiyan Zhao
Haiyan Zhao
XWXiaofang Wen
Xiaofang Wen
NLNa Li
Na Li
JRJujie Ren
Jujie Ren
CZCong Zhang
Cong Zhang

9 July 2019 in Chemical Research in Chinese Universities
Verified
Journal Article
Closed access
PDF file
PDPengfei Dong
Pengfei Dong
NLNa Li
Na Li
HZHaiyan Zhao
Haiyan Zhao
MCMin Cui
Min Cui
CZCong Zhang
Cong Zhang
JRJujie Ren
Jujie Ren

3 March 2023 in Energy Advances
Verified
Journal Article
Open access
PDF file
CCChang Chen
Chang Chen
MCMin Cui
Min Cui
QWQian Wang
Qian Wang
PCPenglei Cui
Penglei Cui
CZCong Zhang
Cong Zhang
JRJujie Ren
Jujie Ren
In situ grown nickel ferrite nanosheets are used as cathode for electro-catalytic N 2 reduction. PBS-isopropanol is used as the electrolyte to improve N 2 solubility and reduce HER, and higher ammonia production rate and FE are obtained.