Xueping Ji

Xueping Ji


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HZHaiyan Zhao
Haiyan Zhao
XJXueping Ji
Xueping Ji
BWBeibei Wang
Beibei Wang
NWNa Wang
Na Wang
XLXianrui Li
Xianrui Li
JRJujie Ren
Jujie Ren

28 October 2023 in Talanta
Verified
Journal Article
Closed access
YNYongzhe Niu
Yongzhe Niu
KKKai Kang
Kai Kang
BWBeibei Wang
Beibei Wang
LWLanyue Wang
Lanyue Wang
CLCongwei Li
Congwei Li
XJXueping Ji
Xueping Ji

11 January 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
KKKai Kang
Kai Kang
BWBeibei Wang
Beibei Wang
XJXueping Ji
Xueping Ji
YLYuheng Liu
Yuheng Liu
WZWenrui Zhao
Wenrui Zhao
JRJujie Ren
Jujie Ren
This study reports a new type of artificial nanozyme based on Hemin-doped-HKUST-1 (HKUST-1, also referred to as MOF-199; a face-centered-cubic MOF containing nanochannels) as a redox mediator for the detection of dopamine (DA). Hemin-doped-HKUST-1 was successfully synthesized by one-pot hydrothermal method, which was combined with reduced graphene oxide (rGO) modified on a glassy carbon electrode (GCE) to construct a sensor (Hemin-doped HKUST-1/rGO/GCE). The morphology and structure of Hemin-doped-HKUST-1 were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), transmission electron microscope (TEM) and infrared spectra (IR) techniques. The Hemin-doped HKUST-1/rGO nanozyme showed an excellent electrocatalytic activity for DA oxidation, which is due to the enhanced Hemin activity through the formation of a metal–organic framework (MOFs) and the synergy between the Hemin-doped HKUST-1 and rGO in nanozyme. The resulted sensor exhibited a high sensitivity of 1.224 μA μM−1, with a lower detection limit of 3.27 × 10−8 M (S/N = 3) and a wide linear range of 0.03–10 μM for DA detection. In addition, due to the stabilizing effect of MOFs on heme, the sensor showed satisfactory stability and has been successfully applied to the detection of DA in serum samples, indicating that this work has potential value in clinical work.

1 May 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
BWBeibei Wang
Beibei Wang
XJXueping Ji
Xueping Ji
HZHaiyan Zhao
Haiyan Zhao
NWNa Wang
Na Wang
XLXianrui Li
Xianrui Li
YLYuheng Liu
Yuheng Liu

1 December 2017 in Bioelectrochemistry
Verified
Journal Article
Closed access
BWBeibei Wang
Beibei Wang
XJXueping Ji
Xueping Ji
JRJujie Ren
Jujie Ren
RNRuixing Ni
Ruixing Ni
LWLin Wang
Lin Wang

22 July 2022 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
CZCong Zhang
Cong Zhang
LFLimin Fan
Limin Fan
JRJujie Ren
Jujie Ren
MCMin Cui
Min Cui
NLNa Li
Na Li
XJXueping Ji
Xueping Ji