Mathieu Darnajou

Dr. Mathieu Darnajou

CEA cadarache
+1

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
ADAntoine Dupré
Antoine Dupré
CDChunhui Dang
Chunhui Dang
GRGuillaume Ricciardi
Guillaume Ricciardi
SBSalah Bourennane
Salah Bourennane
SMSaba Mylvaganam
Saba Mylvaganam
The investigation of quickly-evolving flow patterns in high-pressure and high-temperature flow rigs is crucial due to inherent hazards. There is a dire need for a high-speed, non-intrusive imaging technique to identify characteristic flow phenomena to alleviate these hazards. Electrical Impedance Tomography (EIT) enables reconstruction of the admittivity distribution of the flowing medium(s), facilitating the characterisation of its/their flow. The requirement for images at high framerates led to simultaneous voltage excitations over electrodes on the periphery of the flow associated to Frequency Division Multiplexing (FDM), doped ONe Excitation for Simultaneous High-speed Operation Tomography (ONE-SHOT) method. In previous studies, we have demonstrated the possibility of the full implementation of simultaneous excitations and measurements strategies for EIT, which maximise the number of measurements for 16 electrodes. This article presents the details of the proposed method and the signal generation/acquisition firmware based on a Field Programmable Gate Array (FPGA) data acquisition system focusing on hardware and software integration and the signal processing involved in realising the ONE-SHOT operation of the EIT. It is shown that the simultaneously generated signals are successfully discriminated and used for image reconstruction, at a rate up to 3906 frames per second (fps). The associated signalto-noise ratio varies in the 55.6 dB–69.1 dB range, depending on the generated frequency in the range of 3.906 kHz–468.7 kHz.

3 February 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CDChunhui DANG
Chunhui DANG
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
BCBellis Cedric
Bellis Cedric
GRGuillaume Ricciardi
Guillaume Ricciardi
SMSaba Mylvaganam
Saba Mylvaganam
SBSalah BOURENNANE
Salah BOURENNANE
Gas–liquid two-phase flows are encountered in various industrial processes involving high temperatures and high pressures, which necessitates nonintrusive sensing for real-time imaging of phase distribution and flow parameters. In this context, this article presents an electrical impedance tomography (EIT)-based eigenvalue correlation method that allows extracting two-phase flow features, namely, the void fraction and the flow regime, which are used in turn to improve flow visualizations. Benefiting from the so-called full-scan excitation strategy, the eigenvalue correlation method has been devised in to estimate the phase fraction from EIT raw measurements. In this article, this method is refined and integrated into an image-enhancing procedure, which is illustrated and validated using dynamic experimental data. A total of 80 experiments are considered with water and air mass flow rates ranging from 1.58 to 79.43 kg/min and from 0.1 to 5.0 kg/min, respectively, covering slug, plug, stratified smooth, stratified wavy, and annular flows. Based on a preliminary system calibration and a raw image guess, the volume-averaged void fractions are then estimated using the proposed method and integrated into EIT-based images to form binarized tomograms relative to the acquisition time. The EIT tomograms, thus, obtained show an excellent agreement with some $\gamma $ -ray reference measurements of the phase distribution.

25 May 2021 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CDChunhui DANG
Chunhui DANG
CBCédric Bellis
Cédric Bellis
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
GRGuillaume Ricciardi
Guillaume Ricciardi
SMSaba Mylvaganam
Saba Mylvaganam
SBSalah Bourennane
Salah Bourennane
In the field of electrical impedance tomography (EIT), numerous studies have aimed at the optimal excitation/measurement strategies for improving conductivity distribution imaging, particularly in the applications involving highly contrasted materials. These studies focus on the conditions to be imposed on the currents fed into the electrodes and on their measurement counterparts, while making use of various quantitative optimal criteria. While most EIT systems rely on a sequential excitation at neighboring electrodes with measurements at the remaining ones, some alternative excitation strategies, or protocols, have also proven to be effective and easy to implement using modern hardware. In this context, the present study aims at confronting some of the predominant EIT excitation protocols on a practical system that is dedicated to the imaging of media with highly contrasted material components, i.e. with large variations of the conductivity field. More specifically, the so-called adjacent, opposite, full-scan and trigonometric excitation strategies are considered here and assessed on a number of criteria, which are: complexity of a practical implementation, number of independent measurements, amplitude of the measured responses, sensitivity distribution and quality of the final reconstructed images. For each of these excitation protocols, numerical simulations and static experiments with test objects placed in the EIT sensor considered are carried out using various conductivity profiles, while reconstructed images are evaluated both qualitatively and qualitatively. Our results highlight the preeminence of the full-scan and trigonometric strategies, which are characterized by high response signals and satisfying overall sensitivities. Moreover, for the studied configurations in both numerical simulations and static experiments, the full scan and trigonometric strategies lead to improved contrasts in the reconstructed images of the phases distribution.

24 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
ADAntoine Dupré
Antoine Dupré
CDChunhui DANG
Chunhui DANG
GRGuillaume Ricciardi
Guillaume Ricciardi
SBSalah BOURENNANE
Salah BOURENNANE
BCBellis Cedric
Bellis Cedric
The investigation of quickly-evolving flow patterns in high-pressure and high-temperature flow rigs requires the use of a high-speed and non-intrusive imaging technique. Electrical Impedance Tomography (EIT) allows reconstructing the admittivity distribution characterizing a flow from the knowledge of currents and voltages on its periphery. The need for images at high frame rates leads to the strategy of simultaneous multi-frequency voltage excitations and simultaneous current measurements, which are discriminated using fast Fourier transforms. The present study introduces the theory for a 16-electrode simultaneous EIT system, which is then built based on a field programmable gate array data acquisition system. An analysis of the propagation of uncertainties through the measurement process is investigated, and experimental results with fifteen simultaneous signals are presented. It is shown that the signals are successfully retrieved experimentally at a rate of 1953 frames per second. The associated signal-to-noise ratio varies from 59.6–69.1 dB, depending on the generated frequency. These preliminary results confirm the relevance and the feasibility of simultaneous multi-frequency excitations and measurements in EIT as a means to significantly increase the imaging rate.

18 October 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CDChunhui DANG
Chunhui DANG
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
CBCédric Bellis
Cédric Bellis
GRGuillaume Ricciardi
Guillaume Ricciardi
HSHolger Schmidt
Holger Schmidt
SBSalah Bourennane
Salah Bourennane
Electrical impedance tomography (EIT) is an imaging technique with advantages of non-intrusiveness, low-cost and high temporal resolution, which is promising for multiphase flow instrumentation. However, it produces smooth images with low spatial resolution where the interface between phases cannot be distinguished and from which the phase fraction cannot be estimated correctly. In this article, an eigenvalue analysis of EIT raw data is used to estimate the void fraction, i.e. the phase area ratio in 2D, without reconstructing images. For a given EIT sensor, each acquisition frame is represented by an impedance matrix whose eigenvalues are computed after normalization. The main characteristics of the eigenvalue distribution for different two-phase flow patterns within a cylindrical pipe are analyzed numerically. The behaviors of the leading eigenvalue and of the sum of the absolute values of the following ones are assessed as functions of the void fraction. This leads to an estimation of the two-phase flow void fraction based on the EIT sensor configuration. The presented numerical results highlight the existing correlation between the eigenvalues and the void fraction for the phase distribution patterns considered. These simulation results are compared with experimental static tests for validation.

4 April 2026
Verified
Thesis
Closed access
Mathieu DarnajouMathieu Darnajou
Mathieu Darnajou
Une Nouvelle Approche de la Tomographie par Impédance Electrique Ultra-Rapide avec Multiplexage en Division de Fréquence : du Développement Théorique à l’Application Industrielle: L'analyse des régimes d'écoulement évoluant rapidement dans des plateformes hydrauliques à haute pression et haute température est cruciale du fait de certains risques intrinsèques. Il est urgent de développer une technique d'imagerie non intrusive et à haut rendement d'images pour identifier les phénomènes d'écoulements caractéristiques et palier ces risques. La Tomographie par Impédance Electrique (EIT) permet de reconstruire la distribution de l'admittance du ou des milieu(x) en écoulement, facilitant sa/leur caractérisation.Hormis le développement du système d'Acquisition de Données (DAQ), un intérêt crucial concerne la conception du détecteur lui-même, qui contient un anneau d'électrodes, tangentiel à la surface interne du conduit hydraulique. La principale préoccupation est de déterminer la longueur des électrodes qui maximise leur énergie de surface.Une simulation numérique a été menée pour quantifier les fuites de courant qui dépendent de la surface des électrodes, ainsi que de l'épaisseur d'isolation entre les électrodes et les brides conductrices en amont et en aval. Un maximum de l'énergie de mesure a été trouvé pour des électrodes dont la longueur est de 84 % la longueur du détecteur EIT. Un autre intérêt également développé dans ce travail concerne le comportement contre-intuitif de la carte de sensibilité des mesures. Ce comportement est validé par une méthode de calcul indépendante.La nécessité d'acquérir des images à haut taux a amené à considérer des excitations simultanées en voltage imposées sur les électrodes en périphérie de l'écoulement. Ces excitations sont associées au Multiplexage en Division de Fréquences (FDM) selon la méthode ONE-SHOT (ONe Excitation for Simultaneous High-speed Operation Tomography). Une première approche démontre la possibilité d'une implémentation complète de stratégies d'excitations et de mesures simultanées pour l'EIT, qui maximise le nombre de mesures pour 16 électrodes. Ces résultats préliminaires confirment la pertinence et la faisabilité d'excitations et de mesures simultanées et Multi-Fréquentielles (MF) en EIT comme moyen pour augmenter significativement le taux d'images.Ce travail détaille la méthode proposée ainsi que le système DAQ contenant un firmware pour la génération/acquisition des signaux basé sur un Réseau Logique Programmable (FPGA). L'intégration des logiciels et du matériel informatique ainsi que le traitement du signal impliqué dans l'implémentation de la méthode ONE-SHOT pour l'EIT est également détaillée. Il est démontré que 240 signaux simultanés ont été générés, discriminés avec succès et utilisés pour reconstruire des images, au taux de 3906 images par secondes (fps). Le signal-sur-bruit associé varie de 55.6 dB à 69.1 dB, en fonction de la fréquence générée de 3,906 kHz à 468,7 kHz. La méthode ONE-SHOT a été exploitée avec succès dans deux expériences pour mesurer les caractéristiques des écoulements dans la branche chaude d'un Réacteur à Eau Pressurisée (PWR) en scénario d'Accident de Fuites de Réfrigérant Primaire (LOCA).Finalement, la nouvelle méthode COLTRANE (Continuous Overlapping operations with Linear Trigonometric Response ANalysis for EIT) est introduite et implémentée dans un système DAQ basé sur FPGA pour des détecteurs EIT de 16 et 32 électrodes. Cette nouvelle méthode utilise des patrons d'excitations trigonométriques et simultanées dans le but d'augmenter le taux d'acquisition jusqu'à 32 250 fps. Ces nouveaux systèmes à taux ultra rapides ouvrent l'EIT vers de nouveaux domaines d'application.