Hsiang-Yun Huang

Ms. Hsiang-Yun Huang

National Yang-Ming University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
HHHsiang-Yun Huang
Hsiang-Yun Huang
KLKai-Chun Liu
Kai-Chun Liu
KCKun-Hui Chen
Kun-Hui Chen
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
Total knee arthroplasty (TKA) is one of the most common treatments for people with severe knee osteoarthritis (OA). The accuracy of outcome measurements and quantitative assessments for perioperative TKA is an important issue in clinical practice. Timed up and go (TUG) tests have been validated to measure basic mobility and balance capabilities. A TUG test contains a series of subtasks, including sit-to-stand, walking-out, turning, walking-in, turning around, and stand-to-sit tasks. Detailed information about subtasks is essential to aid clinical professionals and physiotherapists in making assessment decisions. The main objective of this study is to design and develop a subtask segmentation approach using machine-learning models and knowledge-based postprocessing during the TUG test for perioperative TKA. The experiment recruited 26 patients with severe knee OA (11 patients with bilateral TKA planned and 15 patients with unilateral TKA planned). A series of signal-processing mechanisms and pattern recognition approaches involving machine learning-based multi-classifiers, fragmentation modification and subtask inference are designed and developed to tackle technical challenges in typical classification algorithms, including motion variability, fragmentation and ambiguity. The experimental results reveal that the accuracy of the proposed subtask segmentation approach using the AdaBoost technique with a window size of 128 samples is 92%, which is an improvement of at least 15% compared to that of the typical subtask segmentation approach using machine-learning models only.

22 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HHHsiang-Yun Huang
Hsiang-Yun Huang
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
KLKai-Chun Liu
Kai-Chun Liu
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
Fluid intake is important for people to maintain body fluid homeostasis. Inadequate fluid intake leads to negative health consequences, such as headache, dizziness and urolithiasis. However, people in busy lifestyles usually forget to drink sufficient water and neglect the importance of fluid intake. Fluid intake management is important to assist people in adopting individual drinking behaviors. This work aims to propose a fluid intake monitoring system with a wearable inertial sensor using a hierarchical approach to detect drinking activities, recognize sip gestures and estimate fluid intake amount. Additionally, container-dependent amount estimation models are developed due to the influence of containers on fluid intake amount. The proposed fluid intake monitoring system could achieve 94.42% accuracy, 90.17% sensitivity, and 40.11% mean absolute percentage error (MAPE) for drinking detection, gesture spotting and amount estimation, respectively. Particularly, MAPE of amount estimation is improved approximately 10% compared to the typical approaches. The results have demonstrated the feasibility and the effectiveness of the proposed fluid intake monitoring system.

22 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KLKai-Chun Liu
Kai-Chun Liu
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
HHHsiang-Yun Huang
Hsiang-Yun Huang
LCLi-Tzu Chiu
Li-Tzu Chiu
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
Insufficient fluid intake is becoming an actual concern and problem of the elderly with dramatic increase of aging population. Poor fluid intake habits and Dehydration can cause long-term negative effects in mental and physical capabilities, and even death. Typical approaches to monitor individual fluid intake behavior and consumption of fluid quantities mainly rely on self-report, such as questionnaires. However, these typical approaches suffer issues in manual errors and cause additional burdens on the user. In recent years, advantages of wireless sensor networks and pervasive computing technologies have provided the opportunities to create automatic, objective and low-intrusive fluid intake monitoring systems. The aim of this work is to design a 3D-printed smart cup attached with a single accelerometer and drinking event detection algorithm that is feasible to spot fluid intake gestures, especially for detecting drinking events and recognizing complete periods of drinking. Such drinking information about timing and the frequency of fluid intake can reveal fluid intake habits and that is important for clinical assessment and intervention. The finding shows that the best system performance using k-nearest neighbors (k-NN) model with window size of 4s achieves 89.92% and 85.88% F-measure in event-defined and frame-defined evaluation approaches, respectively.

31 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HHHsiang-Yun Huang
Hsiang-Yun Huang
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
KLKai-Chun Liu
Kai-Chun Liu
HCHui-Chun Cheng
Hui-Chun Cheng
SHSteen Hsu
Steen Hsu
CCChia-Tai Chan
Chia-Tai Chan
The interior space of large-scale buildings, such as hospitals, with a variety of departments, is so complicated that people may easily lose their way while visiting. Difficulties in wayfinding can cause stress, anxiety, frustration and safety issues to patients and families. An indoor navigation system including route planning and localization is utilized to guide people from one place to another. The localization of moving subjects is a critical-function component in an indoor navigation system. Pedestrian dead reckoning (PDR) is a technology that is widely employed for localization due to the advantage of being independent of infrastructure. To improve the accuracy of the localization system, combining different technologies is one of the solutions. In this study, a multi-sensor fusion approach is proposed to improve the accuracy of the PDR system by utilizing a light sensor, Bluetooth and map information. These simple mechanisms are applied to deal with the issue of accumulative error by identifying edge and sub-edge information from both Bluetooth and the light sensor. Overall, the accumulative error of the proposed multi-sensor fusion approach is below 65 cm in different cases of light arrangement. Compared to inertial sensor-based PDR system, the proposed multi-sensor fusion approach can improve 90% of the localization accuracy in an environment with an appropriate density of ceiling-mounted lamps. The results demonstrate that the proposed approach can improve the localization accuracy by utilizing multi-sensor data and fulfill the feasibility requirements of localization in an indoor navigation system.

26 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
CCChih-Ya Chang
Chih-Ya Chang
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
HHHsiang-Yun Huang
Hsiang-Yun Huang
YWYung-Tsan Wu
Yung-Tsan Wu
LCLiang-Cheng Chen
Liang-Cheng Chen
KLKai-Chun Liu
Kai-Chun Liu
Advanced sensor technologies have been applied to support frozen shoulder assessment. Sensor-based assessment tools provide objective, continuous and quantitative information for evaluation and diagnosis. However, the current tools for assessment of functional shoulder tasks mainly rely on manual operation. It may cause several technical issues to the reliability and usability of the assessment tool, including manual bias during the recording and additional efforts for data labeling. To tackle these issues, this pilot study aims to propose an automatic functional shoulder task identification and sub-task segmentation system using inertial measurement units to provide reliable shoulder task labeling and sub-task information for clinical professionals. The proposed method combines machine learning models and rule-based modification to identify shoulder tasks and segment sub-tasks accurately. A hierarchical design is applied to enhance the efficiency and performance of the proposed approach. Nine healthy subjects and nine frozen shoulder patients are invited to perform five common shoulder tasks in the lab-based and clinical environments, respectively. The experimental results show that the proposed method can achieve 87.11% F-score for shoulder task identification, and 83.23% F-score and 427 mean absolute time errors (milliseconds) for sub-task segmentation. The proposed approach demonstrates the feasibility of the proposed method to support reliable evaluation for clinical assessment.

25 December 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Chia-Yeh HsiehChia-Yeh Hsieh
Chia-Yeh Hsieh
HHHsiang-Yun Huang
Hsiang-Yun Huang
CCChia-Tai Chan
Chia-Tai Chan
LCLi-Tzu Chiu
Li-Tzu Chiu
Monitoring fluid intake is essential to help people manage their individual fluid intake behaviors and achieve adequate hydration. Previous studies of fluid intake assessment approaches based on inertial sensors can be categorized into wrist-worn-based and smart-container-based approaches. This study aims to analyze wrist-worn-based and smart-container-based fluid intake assessment approaches using inertial sensors. The comparison of these two approaches should be analyzed according to gesture recognition and volume estimation. In addition, the influence of the fill level and sip size information on the performance is explored in this study. The accuracy of gesture recognition with postprocessing is 92.89% and 91.8% for the wrist-worn-based approach and smart-container-based approach, respectively. For volume estimation, sip-size-dependent models can achieve better performance than general SVR models for both wrist-worn-based and smart-container-based approaches. The improvement of MAPE, MAD, and RMSE can reach over 50% except MAPE for small sip sizes. The results demonstrate that the sip size information and recognition performance are important for fluid intake assessment approaches.