In this paper, we design a sensor based on the electromagnetically induced transparency-like (EIT-like) approach in the terahertz range in order to realize a terahertz metamaterial device with an enhanced combination of ${Q}$ value and sensitivity. The Lorentz harmonic oscillator model and the asymmetry parameter are used for analyzing its internal physical mechanism. After processing the designed structure and performing experimental verification, a good consistency between the experiment and theoretical framework is found in terms of the position and strength of the resonance peak. Subsequently, glucose tablets of different concentrations are fabricated in order to verify the practical application of the designed sensor for distinguishing the presence of tablets with different concentrations. Finally, it is found through model optimization and sensor performance evaluation that our prototype exhibits a sensitivity value of about 330 GHz/RIU, a quality factor ${Q}$ of 24, while a recorded transparency peak above 80% is obtained. Therefore, as the metamaterial refractive index sensor presents an enhanced performance, it possesses great perspectives for various practical applications including the potential detection of different pharmaceuticals or biochemical products as well as the identification of various concentrations of the same sample.
In this work, a graphene-based planar terahertz electromagnetically induced transparency-like (EIT-like) metamaterial, composed of two horizontally symmetric mono-layer graphene micro-ring resonators (MRR) and a vertical mono-layer graphene micro-strip resonator (MSR), has been proposed. The transparent window was observed in the y polarization direction. By changing the carrier mobility of the graphene, the transparent window could be opened and closed while the position of the EIT-like window remained unchanged. The physical mechanism of the EIT-like effect was explained by the distribution of the electric field on E z and the three-level $\Lambda $ -type system. The theoretical fitting results based on the Lorentz oscillator model and the S-parameter inversion method were consistent with the numerical simulation results. In addition, the performance of the metamaterial for detecting the refractive index of the surrounding medium was analyzed. Numerical simulation showed that when the FOM exceeded 8.0, the sensitivity was 1.6 THz/RIU. Finally, as the graphene carrier mobility increased, the group delay of the device increased. The delay time reached 1.49 ps, and the group index was as high as 400. The proposed design provides a feasible method for the development of optical switches, biochemical molecular detection, and slow light equipment.
In order to improve the refractive index sensitivity of a localized surface plasmon resonance (LSPR) sensor, we present a new type of LSPR sensor whose refractive index sensitivity can be improved by greatly increasing the plasmon wavelength red-shift of metal–semiconductor core–shell nanoparticles (CSNs). Using extended Mie theory and Au@Cu2−xS CSNs, we theoretically investigate the optical properties of metal–semiconductor CSNs in the entire near-infrared band. Compared with dielectric–metal and metal–metal CSNs under the same conditions, the metal–semiconductor CSNs have a higher double-exponential sensitivity curve because their core and shell respectively support two LSPRs that greatly increase the LSPR red-shift to the entire near-infrared range. It is worth noting that the sensitivity can be improved effectively by increasing the ratio of the shell-thickness to core-radius, instead of decreasing it in the case of the dielectric–metal CSNs. The underlying reason for the enhancement of sensitivity is the increase of repulsive force with the enlargement of shell thickness, which is different from the dielectric–metal CSNs. This design method not only paves the way for utilizing metal–semiconductor CSNs in biology and chemistry, but also proposes new ideas for the design of sensors with high sensitivity.
To overcome the effect of analyte thickness and limitation of single wavelength sensing, we propose an ultra-sensitive stereo metamaterial biosensor with double resonance frequencies based on coupling electric resonance and magnetic resonance. The electromagnetic analysis demonstrates that the double resonance coupling, induced by the stereo double-layer structure, can significantly improve sensitive biosensing at the terahertz frequency. The results show that by changing the size of the structure, each resonance frequency can be independently tuned in the range of 0.5-1.8 THz and the maximum refractive index sensitivity is 930.4 GHz/RIU. These results have significant implications for the detection of samples with different frequency points. The proposed ultra-sensitive stereo metamaterial structure has excellent potential for application in biomolecule detection and differentiation.
9 September 2024 in Measurement Science and Technology
The monitoring of micro-defects or external actions induced vacuum degradation in aerospace vacuum vessels is an important challenge. A vacuum-process monitoring method based on quasi-distributed fiber Bragg grating (FBG) sensing technology is proposed. Due to the influence of environmental noise and vacuum pump operation noise, the raw signals measured by FBG sensors contain a large amount of noises, which affects the measurement accuracy and data analysis. Therefore, the wavelet threshold (WT) denoising method is proposed to analyze the influence of noises on the monitoring signals measured by two different kinds of FBG sensors. The evaluation of the monitoring signals after denoising indicates that the proposed method can effectively remove the noise and significantly improve signal quality. The highest signal-to-noise ratio of the processed signals can reach 37.61 dB and the mean square error is 3.68 × 10−7, while retaining the key features of the original signal. The proposed WT denoising method demonstrates better performance and feasibility compared with moving average filtering and Kalman filtering methods. The study provides critical supports for improving the performance and reliability of the vacuum vessel monitoring system.