It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following total hip arthroplasty (THA) in dermatitis patients suspected to have contact allergy and in patients in general with THA. Furthermore, we compared the prevalence of metal allergy in dermatitis patients with and without THA. The Danish Hip Arthroplasty Registry (DHAR) contained detailed information on 90,697 operations. The Gentofte patch-test database contained test results for patients suspected of having allergic contact dermatitis (n = 18,794). Cases (n = 356) were defined as patch-tested dermatitis patients who also had primary THA performed. Two age- and sex-matched controls (n = 712) from the patch-test database were sought for each case. The prevalence of revision was similar in cases (12%) and in patients from the DHAR (13%). The prevalence of metal allergy was similar in cases and controls. However, the prevalence of metal allergy was lower in cases who were patch-tested after operation (6%) than in those who were patch-tested before operation (16%) (OR = 2.9; 95% CI = 1-8). We found that the risk of surgical revision was not increased in patients with metal allergies and that the risk of metal allergy was not increased in cases who were operated, in comparison to controls. Despite some important study limitations, our observations add to the evidence that the risk of complications in metal allergic patients seems limited.
Background and purpose — Few studies have evaluated the long- and mid-term outcomes after minimally invasive periacetabular osteotomy (PAO). We investigated: (1) the long-term hip survival rate after PAO; (2) the risk of complications and additional surgery after PAO; and (3) the hip function at different follow-up points. Patients and methods — We reviewed 1,385 hips (1,126 patients) who underwent PAO between January 2004 and December 2017. Through inquiry to the Danish National Patient Registry we identified conversions to total hip arthroplasty (THA) and complications after PAO. We evaluated the Hip disability and Osteoarthritis Outcome Score (HOOS) obtained preoperatively, and at 6 months, 2-, 5-, and 10-years’ follow-up. Results — 73 of the 1,385 hips were converted to THA. The overall Kaplan–Meier hip survival rate was 80% (95% CI 68–88) at 14 years with a mean follow-up of 5 years (0.03–14). 1.1% of the hips had a complication requiring surgical intervention. The most common additional surgery was removal of screws (13%) and 11% received a hip arthroscopy. At the 2-year follow-up, HOOS pain improved by a mean of 26 points (CI 24–28) and a HOOS pain score > 50 was observed in 86%. Interpretation — PAO preserved 4 of 5 hips at 14 years, with higher age leading to lower survivorship. The PAO technique was shown to be safe; 1.1% of patients had a complication that demanded surgical intervention. The majority of the patients with preserved hips have no or low pain. The operation is effective with a good clinical outcome.
25 October 2007 in Basic & Clinical Pharmacology & Toxicology
Abstract: Cobalt‐chromium‐molybdenum (CoCrMo) metal‐on‐metal hip prosthesis has had a revival due to their excellent wear properties. However, particulate wear debris and metal ions liberated from the CoCrMo alloys might cause carcinogenicity, hypersensitivity, local and general tissue toxicity, genotoxicity and inflammation‐generating qualities. Nine months after implanting small pieces of CoCrMo alloy intramuscularly and intraperitoneally in rats, we analysed the accumulation of metals with a multi‐element analysis, and the levels of metallothionein I/II with real‐time reverse transcriptase‐polymerase chain reaction in liver and kidney. We found that metal ions are liberated from CoCrMo alloys and suggest that they are released by dissolucytosis, a process where macrophages causes the metallic surface to release metal ions. Animals with intramuscular implants accumulated metal in liver and kidney and metallohionein I/II were elevated in liver tissue. The present data do not tell whether kidney and liver are the primary target organs or what possible toxicological effect the different metal ions might have, but they show that metal ions are liberated from CoCrMo alloys that are not subjected to mechanical wear and that they accumulate in liver and kidney tissue. That the liberated metal ions affect the tissues is supported by an up‐regulation of the detoxifying/pacifying metalloprotein I/II in the liver.
14 March 2013 in Archives of orthopaedic and trauma surgery