José Velázquez Blázquez

Prof. Dr. José Velázquez Blázquez

Universidad Politécnica de Cartagena
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Journal of Advanced Research
Verified
Journal Article
Open access
JBJosé Velázquez Blázquez
José Velázquez Blázquez
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
DPDavid P. Piñero
David P. Piñero
FCFrancisco J.F. Cañavate
Francisco J.F. Cañavate
JBJorge Alio del Barrio
Jorge Alio del Barrio
JAJorge L. Alio
Jorge L. Alio
This work evaluates changes in new morphogeometric indices developed considering the position of anterior and posterior corneal apex and minimum corneal thickness (MCT) point in keratoconus. This prospective comparative study included 440 eyes of 440 patients (age, 7–99 years): control (124 eyes) and keratoconus (KC) groups (316 eyes). Tomographic information (Sirius®, Costruzione Strumenti Oftalmici, Italy) was treated with SolidWorks v2013, creating the following morphogeometric parameters: geometric axis–apex line angle (GA–AP), geometric axis–MCT line angle (GA–MCT, apex line–MCT line angle (AP–MCT), and distances between apex and MCT points on the anterior (anterior AP–MCTd) and posterior corneal surface (posterior AP–MCTd). Statistically significant higher values of GA–AP, GA–MCT, AP–MCT and anterior AP–MCTd were found in the keratoconus group (p ≤ 0.001). Moderate significant correlations of corneal aberrations (r ≥ 0.587, p < 0.001) and corneal thickness parameters (r ≤ −0.414, p < 0.001) with GA–AP and AP–MCT were found. Anterior asphericity was found to be significantly correlated with anterior and posterior AP–MCTd (r ≥ 0.430, p < 0.001). Likewise, GA–AP and AP–MCT showed a good diagnostic ability for the detection of keratoconus, with optimal cutoff values of 9.61° (sensitivity 85.5%, specificity 80.3%) and 18.08° (sensitivity 80.5%, specificity 78.7%), respectively. These new morphogeometric indices allow a clinical characterization of the 3-D structural alteration occurring in keratoconus, with less coincidence in the spatial projection of the apex and MCT points of both corneal surfaces. Future studies should confirm the potential impact on the precision of these indices of the variability of posterior corneal surface measurements obtained with Scheimpflug imaging technology.

15 May 2020 in Acta Ophthalmologica
Verified
Journal Article
Closed access
PDF file
ITIbrahim Toprak
Ibrahim Toprak
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
JBJosé Velázquez Blázquez
José Velázquez Blázquez
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio

9 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JBJose Miguel Bolarin
Jose Miguel Bolarin
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
JBJosé Velázquez Blázquez
José Velázquez Blázquez
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
This work pursues two objectives: defining a new concept of risk probability associated with suffering early-stage keratoconus, classifying disease severity according to the RETICS (Thematic Network for Co-Operative Research in Health) scale. It recruited 169 individuals, 62 healthy and 107 keratoconus diseased, grouped according to the RETICS classification: 44 grade I; 18 grade II; 15 grade III; 15 grade IV; 15 grade V. Different demographic, optical, pachymetric and eometrical parameters were measured. The collected data were used for training two machine-learning models: a multivariate logistic regression model for early keratoconus detection and an ordinal logistic regression model for RETICS grade assessments. The early keratoconus detection model showed very good sensitivity, specificity and area under ROC curve, with around 95% for training and 85% for validation. The variables that made the most significant contributions were gender, coma-like, central thickness, high-order aberrations and temporal thickness. The RETICS grade assessment also showed high-performance figures, albeit lower, with a global accuracy of 0.698 and a 95% confidence interval of 0.623–0.766. The most significant variables were CDVA, central thickness and temporal thickness. The developed web application allows the fast, objective and quantitative assessment of keratoconus in early diagnosis and RETICS grading terms.

11 January 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
JBJosé Velázquez Blázquez
José Velázquez Blázquez
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
JBJose Miguel Bolarin
Jose Miguel Bolarin
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Additive manufacturing is a vanguard technology that is currently being used in several fields in medicine. This study aims to evaluate the viability in clinical practice of a patient-specific 3D model that helps to improve the strategies of the doctor-patient assistance. Data obtained from a corneal topographer were used to make a virtual 3D model by using CAD software, to later print this model by FDM and get an exact replica of each patient’s cornea in consultation. Used CAD and printing software were open-source, and the printing material was biodegradable and its cost was low. Clinic users gave their feedback by means of a survey about their feelings when perceiving with their senses their own printed cornea. There was 82 surveyed, 73.8% (9.74; SD: 0.45) of them considered that the model had helped them a lot to understand their disease, expressing 100% of them their intention of taking home the printed model. The majority highlighted that this new concept improves both quality and clinical service in consultation. Custom-made individualized printed models allow a new patient-oriented perspective that may improve the communication strategy from the ophthalmologist to the patient, easing patient’s understanding of their asymmetric disease and its later treatment.

1 August 2018 in Symmetry
Verified
Journal Article
Open access
PDF file
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
Daniel García Fernández-PachecoDaniel García Fernández-Pacheco
Daniel García Fernández-Pacheco
FCFrancisco José Fernández Cañavate
Francisco José Fernández Cañavate
JBJosé Velázquez Blázquez
José Velázquez Blázquez
JBJose M. Bolarín
Jose M. Bolarín
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
The validation of new methods for the diagnosis of incipient cases of Keratoconus (KC) with mild visual limitation is of great interest in the field of ophthalmology. During the asymmetric progression of the disease, the current diagnostic indexes do not record the geometric decompensation of the corneal curvature nor the variation of the spatial profile that occurs in singular points of the cornea. The purpose of this work is to determine the structural characterization of the asymmetry of the disease by using morpho-geometric parameters in KC eyes with mild visual limitation including using an analysis of a patient-specific virtual model with the aid of computer-aided design (CAD) tools. This comparative study included 80 eyes of patients classified as mild KC according to the degree of visual limitation and a control group of 122 eyes of normal patients. The metric with the highest area under the receiver operating characteristic (ROC) curve was the posterior apex deviation. The most prominent correlation was found between the anterior and posterior deviations of the thinnest point for the mild keratoconic cases. This new custom computational approach provides the clinician with a three-dimensional view of the corneal architecture when the visual loss starts to impair.

11 June 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
RARamón Alifa
Ramón Alifa
David P PiñeroDavid P Piñero
David P Piñero
JBJosé Velázquez Blázquez
José Velázquez Blázquez
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Francisco Cavas-MartínezFrancisco Cavas-Martínez
Francisco Cavas-Martínez
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Keratoconus is an ectatic disorder that is presently considered one of the most prevalent reasons for keratoplasty. Corneal collagen crosslinking (CXL) is the only proven treatment option available that is capable of halting the progression of the disease by stabilizing the cone in 90% of cases, and by also reducing refractive error and maximal keratometry. This study assesses, by means of a 3D morphogeometric analysis procedure developed by our research team, the corneal structure changes that occur immediately after CXL treatment and during a 6 month follow-up period. A total of 19 eyes from 19 patients diagnosed with keratoconus who underwent CXL were included, and several variables derived from the morphogeometric analysis were calculated and evaluated for the pre-operative, 3 month postoperative, and 6 month postoperative states. Significant reductions were detected in central corneal thickness and corneal spherical-like root mean square (RMS) 3 months after surgery, with non-significant regression of the effect afterward. Significant reductions in the total corneal area/volume were found, with some levels of regression after 6 months in certain volumetric parameters. In conclusion, the eyes with higher values for morphogeometric parameters—posterior apex deviation (PAD), anterior minimum thickness point deviation (AMTPD), and posterior minimum thickness point deviation (PMTPD)—seemed more likely to undergo aberrometric improvement as a result of CXL surgery.