Theodora Kostou

Theodora Kostou


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
PPPanagiotis Papadimitroulas
Panagiotis Papadimitroulas
TKTheodora Kostou
Theodora Kostou
Konstantinos ChatzipapasKonstantinos Chatzipapas
Konstantinos Chatzipapas
DVDimitris Visvikis
Dimitris Visvikis
Konstantinos A MountrisKonstantinos A Mountris
Konstantinos A Mountris
GKGeorge C. Kagadis
George C. Kagadis
Pediatric patient-specific dosimetry of ionizing radiation is of great scientific and social interest. Children provide a higher relative cancer-risk from exposure to ionizing radiation compared to adults. The proposed study reviews the recent techniques applied in pediatric imaging and therapy applications for dosimetry purposes. Modern medicine makes use of advance computational tools for the personalization of internal and external dosimetry, especially in the sensitive group of children. Several groups of pediatric computational models have been developed which are combined with Monte Carlo simulations, Machine Learning techniques, and Image Processing algorithms for accurate dosimetry assessment. More specifically, this study reviews the dosimetry applications in pediatric diagnostic procedures, including computed tomography and nuclear medicine applications. Right afterwards, the most recent applications in therapeutic brachytherapy protocols are presented, which is a rather sensitive procedure in pediatrics. Finally, modern tools for dosimetry optimization are discussed, reviewing the most indicative applications with: a) Monte Carlo simulations for pediatric dosimetry assessment b) pediatric computational models, widely used in medical applications and c) Machine Learning techniques that provide an alternative method for estimating individualized absorbed doses.

1 August 2019 in Crystals
Verified
Journal Article
Open access
PDF file
RRRita Ricci
Rita Ricci
TKTheodora Kostou
Theodora Kostou
Konstantinos ChatzipapasKonstantinos Chatzipapas
Konstantinos Chatzipapas
EFEleftherios Fysikopoulos
Eleftherios Fysikopoulos
GLGeorge Loudos
George Loudos
Stratos DavidStratos David
Stratos David
Optical Monte Carlo simulations have been extensively used for the accurate modeling of light transport in scintillators for the improvement of detector designs. In the present work, a GATE Monte Carlo toolkit was used to study the effect of scintillator thicknesses and septa materials in the performance parameters evaluation of a commercially available small animal gamma-optical camera, named “γ-eye”. Firstly, the simulated γ-eye system was validated against experimental data. Then, part of the validated camera was modeled defining all of the optical properties by means of the UNIFIED model of GATE. Different CsI:Na scintillator crystals with varying thicknesses (from 4 mm up to 6 mm) and different reflector (septa) materials were simulated and compared in terms of sensitivity, light output and spatial resolution. Results have demonstrated the reliability of the model and indicate that the thicker crystal array presents higher sensitivity values, but degraded spatial resolution properties. Moreover, the use of black tape around crystals leads to an improvement in spatial resolution values compared to a standard white reflector material.