Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.
Ionizing radiation is a common tool in medical procedures. Monte Carlo (MC) techniques are widely used when dosimetry is the matter of investigation. The scientific community has invested, over the last 20 years, a lot of effort into improving the knowledge of radiation biology. The present article aims to summarize the understanding of the field of DNA damage response (DDR) to ionizing radiation by providing an overview on MC simulation studies that try to explain several aspects of radiation biology. The need for accurate techniques for the quantification of DNA damage is crucial, as it becomes a clinical need to evaluate the outcome of various applications including both low- and high-energy radiation medical procedures. Understanding DNA repair processes would improve radiation therapy procedures. Monte Carlo simulations are a promising tool in radiobiology studies, as there are clear prospects for more advanced tools that could be used in multidisciplinary studies, in the fields of physics, medicine, biology and chemistry. Still, lot of effort is needed to evolve MC simulation tools and apply them in multiscale studies starting from small DNA segments and reaching a population of cells.
Purpose: The scientific community shows great interest in the study of DNA damage induction, DNA damage repair, and the biological effects on cells and cellular systems after exposure to ionizing radiation. Several in silico methods have been proposed so far to study these mechanisms using Monte Carlo simulations. This study outlines a Geant4‐DNA example application, named “molecularDNA”, publicly released in the 11.1 version of Geant4 (December 2022).Methods: It was developed for novice Geant4 users and requires only a basic understanding of scripting languages to get started. The example includes two different DNA‐scale geometries of biological targets, namely “cylinders” and “human cell”. This public version is based on a previous prototype and includes new features, such as: the adoption of a new approach for the modeling of the chemical stage, the use of the standard DNA damage format to describe radiation‐induced DNA damage, and upgraded computational tools to estimate DNA damage response.Results: Simulation data in terms of single‐strand break and double‐strand break yields were produced using each of the available geometries. The results were compared with the literature, to validate the example, producing less than 5% difference in all cases. Conclusion: “molecularDNA” is a prototype tool that can be applied in a wide variety of radiobiology studies, providing the scientific community with an open‐access base for DNA damage quantification calculations. New DNA and cell geometries for the “molecularDNA” example will be included in future versions of Geant4‐DNA.
Purpose: This study aims to standardize the simulation procedure in measuring DNA double‐strand breaks (DSBs), by using advanced Monte Carlo toolkits, and newly introduced experimental methods for DNA DSB measurement.Methods: For the experimental quantification of DNA DSB, an innovative DNA dosimeter was used to produce experimental data. GATE in combination with Geant4‐DNA toolkit were exploited to simulate the experimental environment. The PDB4DNA example of Geant4‐DNA was upgraded and investigated. Parameters of the simulation such energy threshold (ET) for a strand break and base pair threshold (BPT) for a DSB were evaluated, depending on the dose.Results: Simulations resulted to minimum differentiation in comparison to experimental data for ET = 19 ± 1 eV and BPT = 10 bp, and high differentiation for ET<17.5 eV or ET>22.5 eV and BPT = 10 bp. There was also small differentiation for ET = 17.5 eV and BPT = 6 bp. Uncertainty has been kept lower than 3%.Conclusions: This study includes first results on the quantification of DNA double‐strand breaks. The energy spectrum of a LINAC was simulated and used for the first time to irradiate DNA molecules. Simulation outcome was validated on experimental data that were produced by a prototype DNA dosimeter.
We present GATE version 10, a major evolution of the open-source Monte Carlo simulation application for medical physics, built on Geant4. This release marks a transformative evolution, featuring a modern Python-based user interface, enhanced multithreading and multiprocessing capabilities, the ability to be embedded as a library within other software, and a streamlined framework for collaborative development. In this Part 1 paper, we outline GATE’s position among other Monte Carlo codes, the core principles driving this evolution, and the robust development cycle employed. We also detail the new features and improvements. Part 2 will focus on the architectural innovations and technical challenges. By combining an open, collaborative framework with cutting-edge features, such a Monte Carlo platform supports a wide range of academic and industrial research, solidifying its role as a critical tool for innovation in medical physics.