Solution concentration measurement is of great significance in various fields. Various optical fiber solution concentration sensors have been developed accordingly, in which the Fresnel refraction-based optical fiber sensor has the advantages of avoiding damage to sensing units, reusability, and low maintenance cost. In this study, a tilted fiber Bragg grating (TFBG) side modes and Fresnel reflection-based sensing system for solution concentration measurement is proposed. Theoretically and experimentally, the non-uniformity of the grating period causing the forming of irregular TFBG side mode fringes is simulated and proved, and the feasibility of the dip intensity of the TFBG side mode resonance to quantitatively characterize the solution concentration is demonstrated. As a result, a maximum concentration sensitivity of -0.471 dB/% at the glycerol solution concentration of 95.83% is achieved by increasing outpower of the light source and using optical circulator. In addition, a method for simultaneous measurement of solution temperature and refractive index by using one side mode resonance signal is proposed and proved, which can significantly reduce the response time and improve the accuracy of concentration measurement.
In this study, in-situ electroplating method was used to fabricate a metal joint fixed extrinsic Fabry-Perot interferometric (EFPI) sensor. Specifically, optical fibers were firstly chemical plated with a very thin conductive nickel layer and then electroplated with nickel coating. After that, in-situ electroplating method was used to fix the metallized optical fibers and the capillary steel tube, the reflection spectra changes of the EFPI sensors during the in-situ electroplating process were recorded in real time, and the temperature sensing characteristics of the EFPI sensors were studied assisted by the temperature sensing system. Results show that: (i) optical fibers are well protected by the nickel layer; (ii) the reflection spectra of the EFPI sensors are clear and complete in the whole in-situ electroplating process, it is feasible to fabricate a EFPI sensor with the in-situ electroplating method; (iii) with the increases of temperature, the peak numbers of the reflection spectra of the EFPI sensors increase gradually; (iv) the EFPI sensors with different cavity length based on the in-situ electroplating method show excellent sensing characteristics, the temperature sensitivities reach up to about 700, 600, and 400 pm/°C from room temperature to 400 °C, respectively.