Hannah Licharz

Mrs. Hannah Licharz


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
HLHannah Licharz
Hannah Licharz
PRPeter Rösmann
Peter Rösmann
MKManuel S. Krommweh
Manuel S. Krommweh
EMEhab Mostafa
Ehab Mostafa
Wolfgang BuescherWolfgang Buescher
Wolfgang Buescher
This study describes a 70-day investigation of three identical groundwater heat pumps (GWHP) for heating two pig houses located on the same farm in West Germany. Two of the three GWHPs were installed in a piglet-rearing barn, the third in a farrowing barn. All three heat pumps were fed from the same extraction well. The aim of this study was firstly the empirical performance measurement of the GWHP systems and secondly the energetic evaluation of the systems on barn level by calculating the coefficient of performance (COP). Three different assessment limits were considered in order to better identify factors influencing the COP. In total, the heat pumps supplied thermal energy of 47,160 kWh (piglet-rearing barn) and 36,500 kWh (farrowing barn). Depending on the assessment limit considered, the COP in piglet-rearing barn and farrowing barn ranged between 2.6–3.4 and 2.5–3.0, respectively. A significant factor influencing the COP is the amount of electrical current required to operate the groundwater feeding pump. The average groundwater flow rate was 168.4 m3 d−1 (piglet-rearing barn) and 99.1 m3 d−1 (farrowing barn). In conclusion, by using energy from groundwater, GWHPs have the potential to substitute fossil fuels, thus saving them and avoiding CO2 emissions.

10 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
MKManuel S. Krommweh
Manuel S. Krommweh
HDHauke Ferdinand Deeken
Hauke Ferdinand Deeken
HLHannah Licharz
Hannah Licharz
Wolfgang BuescherWolfgang Buescher
Wolfgang Buescher
In this study, biological exhaust air treatment was combined with a recuperative heat exchanger in one process stage. The aim of this plant development and testing is not only to reduce ammonia from the exhaust air of pig houses but also to recover thermal energy at the same time. This is intended to offset the high operating costs of exhaust air treatment with savings of heating costs in cold seasons and to use the plant more efficiently. This system was tested for the first time under practical conditions in a pig fattening house in southern Germany. Three different assembly situations of the heat exchanger were examined for 13 days each and then compared with each other. The heating performance of the plant is primarily dependent on the outside air temperature and secondarily on the scrubbing water temperature. Depending on the assembly situation of the heat exchanger, an average heating performance of between 6.0 and 10.0 kW was observed; the amount of recovered thermal energy was between 1860 and 3132 kWh. The coefficient of performance (COP) ranked between 7.1 and 11.5. Furthermore, ammonia removal up to 64% was demonstrated. A long-term investigation of the system under practical conditions is recommended to validate the data collected in this study.