Earthquakes are one of the major natural calamities as well as a prime subject of interest for seismologists, state agencies, and ground motion instrumentation scientists. The real-time data analysis of multi-sensor instrumentation is a valuable knowledge repository for real-time early warning and trustworthy seismic events detection. In this work, an early warning in the first 1 micro-second and seismic wave detection in the first 1.7 milliseconds after event initialization is proposed using a seismic wave event detection algorithm (SWEDA). The SWEDA with nine low-computation-cost operations is being proposed for smart geospatial bi-axial inclinometer nodes (SGBINs) also utilized in structural health monitoring systems. SWEDA detects four types of seismic waves, i.e., primary (P) or compression, secondary (S) or shear, Love (L), and Rayleigh (R) waves using time and frequency domain parameters mapped on a 2D mapping interpretation scheme. The SWEDA proved automated heterogeneous surface adaptability, multi-clustered sensing, ubiquitous monitoring with dynamic Savitzky–Golay filtering and detection using nine optimized sequential and structured event characterization techniques. Furthermore, situation-conscious (context-aware) and automated computation of short-time average over long-time average (STA/LTA) triggering parameters by peak-detection and run-time scaling arrays with manual computation support were achieved.
Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig.
Indoor air quality and respiratory health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spiked during the pandemic when indoor air pollution became a threat to living beings, especially human beings. Problem Definition: Indoor respiration-associated diseases are hard to diagnose if they are due to indoor environmental conditions. A major challenge was observed in establishing a baseline between indoor air quality sensors and associated respiratory diseases. Methods: In this work, 10,000+ articles from top literature databases were reviewed using six bibliometric analysis methods (Lorenz Curve of Citations, Hirch’s H-Index, Kosmulski’s H2-Index, Harzing’s Hl-Norm-Index, Sidoropolous’s HC-Index, and Schrieber’s HM-index) to formulate indoor air quality sensor and disease correlation publication rubrics to critically review 482 articles. Results: A set of 152 articles was found based on systematic review parameters in six bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA-defined principles. Five major respiratory diseases were found to be causing major death toll (up to 32%) due to five key pollutants, measured by 30+ low-cost sensors and further optimized by seven calibration systems for seven practical parameters tailored to respiratory disease baselines evaluated through 10 cost parameters. Impact: This review was conducted to assist end-users, public health facilities, state agencies, researchers, scientists, and air quality protection agencies.
1 December 2020 in Advances in Science, Technology and Engineering Systems Journal
The current COVID-19 pandemic has raised huge concerns about outdoor air quality due to the expected lung deterioration. These concerns include the challenges associated with an increase of harmful gases like carbon dioxide, the iterative/repetitive inhalation due to mask usage, and harsh environmental temperatures. Even in the presence of air quality sensing devices, these challenges can hinder the prevention and treatment of respiratory diseases, epidemics, and pandemics in severe cases. In this research, a dual time series with a bi-cluster sensor data-stream-based novel optimized regression algorithm was proposed with optimization predictors and responses that use an automated iterative optimization of the model based on the similarity coefficient index. The algorithm was implemented over SeReNoV2 sensor nodes data, i.e., a multi-variate dual time-series sensor, of the environmental and US Environmental Protection Agency standard, which measures variables for the air quality index using air quality sensors with geospatial profiling. The SeReNoV2 systems were placed at four locations that were 3 km apart to monitor the air quality and their data was collected at Ubidots IoT platform over GSM. The results have shown that the proposed technique achieved a root mean square error (RMSE) of 1.0042 with a training time of 469.28 s for the control and an RMSE of 1.646 in a training time of 28.53 s when optimized. The estimated R-Squared error was 0.03, with the Mean-Square Error for temperature being 1.0084 °C, and 293.98 ppm for CO2. Furthermore, the Mean-Absolute Error (MAE) for temperature was 0.66226 °C and 10.252 ppm for the correlated-CO2 at a predicted speed of ~5100 observations/s. In the sample cluster for temperature, 45,000 observations/s for CO2 was achieved due to the iterative optimization of the training time (469.28 s). The correlated temperature and a time of 28.53 s for CO2 were very promising in forecasting COVID-19 countermeasures before time.
Indoor air quality and public health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spikes during the time of pandemic and epidemics when indoor air pollution becomes a threat to living beings especially human beings. Indoor diseases are hard to diagnose if they are due to the indoor environmental conditions. A major challenge was observed in establishing a baseline between the indoor air quality sensors and associated diseases. In this work, 10,000+ articles from top literature databases were reviewed using bibliometric analysis to formulate indoor air quality sensors and diseases correlation rubrics to critically review 500+ articles. A set of 200+ articles were selected based on for detailed study based on seven bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA defined principles. This review has been conducted to assist end-users, public health facilities, state agencies, researchers, scientists and air quality protection agencies.