Ankica Šarić

Dr. Ankica Šarić

Rudjer Boskoovic Institute, Zagreb, Croatia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
Ankica ŠarićAnkica Šarić
Ankica Šarić
IDInes Despotović
Ines Despotović
GŠGoran Štefanić
Goran Štefanić

25 September 2019 in Coatings
Verified
Journal Article
Open access
PDF file
JKJozefina Katić
Jozefina Katić
Ankica ŠarićAnkica Šarić
Ankica Šarić
Ines DespotovicInes Despotovic
Ines Despotovic
Nives Matijaković MlinarićNives Matijaković Mlinarić
Nives Matijaković Mlinarić
MPMarin Petković
Marin Petković
Željka PetrovićŽeljka Petrović
Željka Petrović
In recent years, extensive studies have been continuously undertaken on the design of bioactive and biomimetic dental implant surfaces due to the need for improvement of the implant–bone interface properties. In this paper, the titanium dental implant surface was modified by bioactive vitamin D3 molecules by a self-assembly process in order to form an improved anticorrosion coating. Surface characterization of the modified implant was performed by field emission scanning electron microscopy (FE-SEM), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), and contact angle measurements (CA). The implant’s electrochemical stability during exposure to an artificial saliva solution was monitored in situ by electrochemical impedance spectroscopy (EIS). The experimental results obtained were corroborated by means of quantum chemical calculations at the density functional theory level (DFT). The formation mechanism of the coating onto the titanium implant surface was proposed. During a prolonged immersion period, the bioactive coating effectively prevented a corrosive attack on the underlying titanium (polarization resistance in order of 107 Ω cm2) with ~95% protection effectiveness.

1 February 2022 in Inorganic Chemistry
Verified
Journal Article
Closed access
Ankica ŠarićAnkica Šarić
Ankica Šarić
MVMartina Vrankić
Martina Vrankić
DLDirk Lützenkirchen-Hecht
Dirk Lützenkirchen-Hecht
IDInes Despotović
Ines Despotović
Željka PetrovićŽeljka Petrović
Željka Petrović
FEFranz Eckelt
Franz Eckelt

31 October 2017 in ChemistrySelect
Verified
Journal Article
Closed access
PDF file
Ankica ŠarićAnkica Šarić
Ankica Šarić
Ines DespotovicInes Despotovic
Ines Despotovic
GŠGoran Štefanić
Goran Štefanić
Goran DrazicGoran Drazic
Goran Drazic

22 March 2017 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
SRS. Richard
S. Richard
MBM. Boucher
M. Boucher
Ankica ŠarićAnkica Šarić
Ankica Šarić
AHA. Herbet
A. Herbet
YLY. Lalatonne
Y. Lalatonne
LMLaurence Motte
Laurence Motte
PEGylation has been established as a valuable strategy to minimize nanoparticle clearance by the reticulo-endothelial system due to hydrophilicity and steric repulsion of PEG chains. In this study we functionalized superparamagnetic iron oxide nanoparticle surface with two PEG differing in their length (n = 23 and 44) and terminal functionality, COOH and CH3. By varying the ratio of the two different PEG, we optimized the molecular architecture of the nanoplatform to obtain maximum stability and low toxicity under physiological conditions. The best nanoplatform was evaluated as MRI contrast for mouse brain vascularization imaging at 7 T. The carboxylic acid functions of the nanoplatform were used to covalently bind an antibody, Ab. This antibody, labeled with a fluorophore, targets the ETA receptor, a G-protein-coupled receptor involved in the endothelin axis and overexpressed in various solid tumours, including ovarian, prostate, colon, breast, bladder and lung cancers. In vitro studies, performed by flow cytometry and magnetic quantification, showed the targeting efficiency of the Ab-nanoplatforms. Clearly, an imaging tracer for cancer diagnosis from a bimodal contrast agent (fluorescence and MRI) was thus obtained.

20 July 2020 in Materials
Verified
Journal Article
Open access
PDF file
Željka PetrovićŽeljka Petrović
Željka Petrović
Ankica ŠarićAnkica Šarić
Ankica Šarić
Ines DespotovicInes Despotovic
Ines Despotovic
JKJozefina Katić
Jozefina Katić
RPRobert Peter
Robert Peter
MPMarin Petković
Marin Petković
Organophosphorus compounds, like bisphosphonates, drugs for treatment and prevention of bone diseases, have been successfully applied in recent years as bioactive and osseoinductive coatings on dental implants. An integrated experimental-theoretical approach was utilized in this study to clarify the mechanism of bisphosphonate-based coating formation on dental implant surfaces. Experimental validation of the alendronate coating formation on the titanium dental implant surface was carried out by X-ray photoelectron spectroscopy and contact angle measurements. Detailed theoretical simulations of all probable molecular implant surface/alendronate interactions were performed employing quantum chemical calculations at the density functional theory level. The calculated Gibbs free energies of (TiO2)10–alendronate interaction indicate a more spontaneous exergonic process when alendronate molecules interact directly with the titanium surface via two strong bonds, Ti–N and Ti–O, through simultaneous participation common to both phosphonate and amine branches. Additionally, the stability of the alendronate-modified implant during 7 day-immersion in a simulated saliva solution has been investigated by using electrochemical impedance spectroscopy. The alendronate coating was stable during immersion in the artificial saliva solution and acted as an additional barrier on the implant with overall resistivity, R ~ 5.9 MΩ cm2.