Photoacoustic spectroscopy is a highly sensitive technique, well suited for and used in applications targeting the accurate measurement of water vapor in a wide range of concentrations. This work demonstrates the nonlinear photoacoustic response obtained for water vapor in air at typical atmospheric concentration levels, which is a result of the resonant vibrational coupling of water and oxygen. Relevant processes in the relaxation path of water in a mixture with air, excited with near-infrared radiation, are identified and a physical model for the acoustic signal measured with a resonant photoacoustic cell is presented. The model is valid for modulation frequencies typical for conventional and quartz-enhanced photoacoustic spectroscopy and provides a simplified means of calibration for photoacoustic water vapor sensors. Estimated values for comprised model coefficients are evaluated from photoacoustic measurements of water vapor in synthetic air. Furthermore, it is shown experimentally that the process of vibrational excitation of nitrogen is of negligible importance in the relaxation path of water vapor and thus insignificant in the photoacoustic heat production in atmospheric measurement environments.
Sensors for the reliable measurement of nitrogen dioxide concentrations are of high interest due the adverse health effects of this pollutant. This work employs photothermal spectroscopy to measure nitrogen dioxide concentrations at the parts per billion level. Absorption induced temperature changes are detected by means of a fiber-coupled Fabry–Pérot interferometer. The small size of the interferometer enables small detection volumes, paving the way for miniaturized sensing concepts as well as fast response times, demonstrated down to 3 s. A normalized noise equivalent absorption of cm−1W/ is achieved. Additionally, due to the rigid structure of the interferometer, the sensitivity to mechanical vibrations is shown to be minor.
Photothermal spectroscopy, and more specifically photothermal interferometry (PTI), is a highly sensitive technique for measuring gas and aerosol concentrations. Numerous implementations of different PTI configurations have demonstrated the versatility of the technique. This theoretical study presents a comprehensive analysis and an optimization of the PTI optical path length (OPL) amplitude using characteristic times. We investigate how the OPL amplitude depends on the dimensions and orientations of the interferometer laser beam and the continuous-wave excitation laser beam. This analysis quantifies the impact of advection on the OPL amplitude based on the relative orientation of the two laser beams and the gas flow direction. It is analytically shown that the possibilities for photothermal OPL amplitude optimization are limited when thermal diffusion is dominant. Theoretically, advection has the potential to double or cancel the OPL amplitude, depending on the specific configurations. In summary, we provide an in-depth understanding of the design and parameter considerations required when tailoring and optimizing a PTI sensor for different fields of applications.
This paper presents an all-fiber, miniature Fabry-Perot gas sensor based on photothermal absorption spectroscopy with a custom-made and cost-efficient interrogation system. The sensing gas microcell has a diameter of 125 μm, a length of 1 mm, and allows for free gas exchange within the optical resonator through micromachined slits. High light intensity and confinement is ensured by delivering the excitation light directly into the gas microcell through a lead-in single-mode fiber. This enhances the photothermal effect and provides a short system response time. The interrogation system utilizes the modulation of an excitation laser diode with a fixed frequency while locking the probe laser onto the gas microcell’s quadrature point and observing the variations of the reflected optical power. To show the potential of the proposed system, nitrogen dioxide was measured in dry air. Thereby, a limit of detection of 20 ppm could be achieved for 10 seconds’ integration time. Furthermore, the small dimensions of the sensor allow for improved dynamic performance with photothermal modulation frequencies as high as 7 kHz.
Photothermal spectroscopy (PTS) is a promising sensing technique for the measurement of gases and aerosols. PTS systems using a Fabry–Pérot interferometer (FPI) are considered particularly promising owing to their robustness and potential for miniaturization. However, limited information is available on viable procedures for signal improvement through parameter tuning. In our work, we use an FPI-based PTS configuration, in which the excitation laser irradiates the target collinearly to the flowing gas. We demonstrate that the generated thermal wave, and thus the signal intensity, is significantly affected by the ratio between excitation modulation frequency and gas flow velocity towards another. We provide an analytical model that predicts the signal intensity with particular considerations of these two parameter settings and validate the findings experimentally. The results reveal the existence of an optimal working regime, depending on the modulation frequency and flow velocity.
31 March 2021 in Atmospheric Measurement Techniques
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, aviation testing, and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12 360 ppm (5 % from 250–21 200 ppm) with a theoretical limit of detection (3σ) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel applications, for which a general description of total condensed water content (CWC) measurements and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 , a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 ∘C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions.