Philipp Breitegger

Dr. Philipp Breitegger

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PBPhilipp Breitegger
Philipp Breitegger
BLBenjamin Lang
Benjamin Lang
ABAlexander Bergmann
Alexander Bergmann
Sensors for the reliable measurement of nitrogen dioxide concentrations are of high interest due the adverse health effects of this pollutant. This work employs photothermal spectroscopy to measure nitrogen dioxide concentrations at the parts per billion level. Absorption induced temperature changes are detected by means of a fiber-coupled Fabry–Pérot interferometer. The small size of the interferometer enables small detection volumes, paving the way for miniaturized sensing concepts as well as fast response times, demonstrated down to 3 s. A normalized noise equivalent absorption of 7.5 × 10 − 8 cm−1W/ Hz is achieved. Additionally, due to the rigid structure of the interferometer, the sensitivity to mechanical vibrations is shown to be minor.

16 July 2019 in Aerosol Science and Technology
Verified
Journal Article
Open access
PBPhilipp Breitegger
Philipp Breitegger
MSMario A. Schriefl
Mario A. Schriefl
RNRobert T. Nishida
Robert T. Nishida
SHSimone Hochgreb
Simone Hochgreb
ABAlexander Bergmann
Alexander Bergmann
Soot Mass Concentration Sensor using Quartz-Enhanced Photoacoustic Spectroscopy. Aerosol Science and Technology. Accepted 9 June 2019.

7 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
PBPhilipp Breitegger
Philipp Breitegger
ABAlexander Bergmann
Alexander Bergmann
A gas diluter based on critical orifices was built and evaluated. The gas diluter is capable of creating dilution ratios of 1:1400 at a total flow of 6.5 L/min. An extended uncertainty analysis of gas concentrations and dilution ratios according to the Guide to the Expression of Uncertainty in Measurement was conducted. A gas cylinder of 5.16 ppm NO2 with a relative uncertainty of 1.5% (k = 1) can be diluted down to a concentration of 3.69 ppb NO2 (dilution ratio of 1:1400) at an uncertainty of 1.9% (k = 1). The results are in good agreement with reference NO2 measurements, conducted with a chemiluminescence detector (CLD, European reference method EN14211; 2005).

22 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
AKAlexander Kerschhofer
Alexander Kerschhofer
PBPhilipp Breitegger
Philipp Breitegger
ABAlexander Bergmann
Alexander Bergmann
The rising effort to track local air pollution measurements require low-cost air quality sensors that provide good accuracy, long-term stability and possibly Internet of Things (IoT) connectivity. To provide such a solution and avoid cost-intensive equipment the development of a low-cost environmental sensor system was started. To measure the pollutant NO2, a quartz-enhanced photoacoustic spectroscopy (QEPAS) setup was established. A pulsed 450 nm laser diode excites NO2 molecules due to its strong absorption at this wavelength and causes a vibrational-translational relaxation, which results in an acoustic wave. The acoustic wave is detected by a quartz tuning fork (QTF) which generates a weak electrical signal proportional to the NO2 concentration. To realize this at low cost, a laser driver and an analysis circuit including a lock-in amplifier and analog-to-digital conversion were developed. We present first results, which proof the functionality of the circuitry compared to a more expensive laboratory setup.

31 March 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
BLBenjamin Lang
Benjamin Lang
WBWolfgang Breitfuss
Wolfgang Breitfuss
SSSimon Schweighart
Simon Schweighart
PBPhilipp Breitegger
Philipp Breitegger
HPHugo Pervier
Hugo Pervier
ABAlexander Bergmann
Alexander Bergmann
This work describes the latest design, calibration and application of a near-infrared laser diode-based photoacoustic (PA) hygrometer developed for total water content measurement in simulated atmospheric freezing precipitation and high ice water content conditions with relevance in fundamental icing research, aviation testing, and certification. The single-wavelength and single-pass PA absorption cell is calibrated for molar water vapor fractions with a two-pressure humidity generator integrated into the instrument. Laboratory calibration showed an estimated measurement accuracy better than 3.3 % in the water vapor mole fraction range of 510–12 360 ppm (5 % from 250–21 200 ppm) with a theoretical limit of detection (3σ) of 3.2 ppm. The hygrometer is examined in combination with a basic isokinetic evaporator probe (IKP) and sampling system designed for icing wind tunnel applications, for which a general description of total condensed water content (CWC) measurements and uncertainties are presented. Despite the current limitation of the IKP to a hydrometeor mass flux below 90 gm-2s-1 , a CWC measurement accuracy better than 20 % is achieved by the instrument above a CWC of 0.14 g m−3 in cold air (−30 ∘C) with suitable background humidity measurement. Results of a comparison to the Cranfield University IKP instrument in freezing drizzle and rain show a CWC agreement of the two instruments within 20 %, which demonstrates the potential of PA hygrometers for water content measurement in atmospheric icing conditions.

17 November 2025 in Animals
Verified
Journal Article
Open access
PDF file
JGJulia Gleissenberger
Julia Gleissenberger
PBPhilipp Breitegger
Philipp Breitegger
MGMatthias Gleissenberger
Matthias Gleissenberger
MAMichael Astl
Michael Astl
DEDaniel Eingang
Daniel Eingang
TWThomas Wittek
Thomas Wittek
Hypocalcemia commonly affects dairy cows around calving or at the onset of lactation. An individual risk prediction would allow customized prophylactic measures and targeted intervention. This study aimed to measure concentrations of total (tCa) and ionized calcium (iCa) during the peripartal period, record rumen motility and temperature patterns, and assess the associations between patterns before calving and Ca concentration at calving. A total of 89 calvings from 47 cows and 22 heifers were monitored using reticuloruminal bolus sensors over 60 days prior to the expected calving and 60 days postpartum. Cows with low tCa (<1.8 mmol/L) or iCa (2.2 mmol/L). Using a rumination time (RT) threshold of 480 min/day on day −1, hypocalcemia was predicted with 66.7% sensitivity and 96.8% specificity. Additionally, we evaluated a deep learning model trained on external data, which incorporated rumen cycles, reticular contraction duration, and reticular temperature. Despite not being trained on this dataset, the model surpassed the RT thresholding approach, achieving 83.2% sensitivity and 98.2% specificity for tCa-based classification. These results indicate superior performance and greater generalizability of the deep learning approach, highlighting the potential of multi-metric sensor analytics to improve early hypocalcemia risk detection.