Stephanie Zhang

Ms. Stephanie Zhang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2024 in Molecular Pharmaceutics
Verified
Journal Article
Closed access
JGJohn Gleeson
John Gleeson
SZStephanie Zhang
Stephanie Zhang
NSNatalia Subelzu
Natalia Subelzu
JLJing Ling
Jing Ling
BNBecky Nissley
Becky Nissley
FKFilippos Kesisoglou
Filippos Kesisoglou

8 April 2024 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
SZStephanie Zhang
Stephanie Zhang
WOWhitney S.Y. Ong
Whitney S.Y. Ong
NSNatalia Subelzu
Natalia Subelzu
JGJohn Gleeson
John Gleeson

22 October 2019 in Cells
Verified
Journal Article
Open access
PDF file
CPCaroline D. Pena
Caroline D. Pena
SZStephanie Zhang
Stephanie Zhang
RMRobert Majeska
Robert Majeska
TVTadmiri Venkatesh
Tadmiri Venkatesh
MVMaribel Vazquez
Maribel Vazquez
Regenerative retinal therapies have introduced progenitor cells to replace dysfunctional or injured neurons and regain visual function. While contemporary cell replacement therapies have delivered retinal progenitor cells (RPCs) within customized biomaterials to promote viability and enable transplantation, outcomes have been severely limited by the misdirected and/or insufficient migration of transplanted cells. RPCs must achieve appropriate spatial and functional positioning in host retina, collectively, to restore vision, whereas movement of clustered cells differs substantially from the single cell migration studied in classical chemotaxis models. Defining how RPCs interact with each other, neighboring cell types and surrounding extracellular matrixes are critical to our understanding of retinogenesis and the development of effective, cell-based approaches to retinal replacement. The current article describes a new bio-engineering approach to investigate the migratory responses of innate collections of RPCs upon extracellular substrates by combining microfluidics with the well-established invertebrate model of Drosophila melanogaster. Experiments utilized microfluidics to investigate how the composition, size, and adhesion of RPC clusters on defined extracellular substrates affected migration to exogenous chemotactic signaling. Results demonstrated that retinal cluster size and composition influenced RPC clustering upon extracellular substrates of concanavalin (Con-A), Laminin (LM), and poly-L-lysine (PLL), and that RPC cluster size greatly altered collective migratory responses to signaling from Fibroblast Growth Factor (FGF), a primary chemotactic agent in Drosophila. These results highlight the significance of examining collective cell-biomaterial interactions on bio-substrates of emerging biomaterials to aid directional migration of transplanted cells. Our approach further introduces the benefits of pairing genetically controlled models with experimentally controlled microenvironments to advance cell replacement therapies.

14 December 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SZStephanie Zhang
Stephanie Zhang
GMGretchen Mahler
Gretchen Mahler
Microphysiological systems (MPS) are powerful predictive tools for assessing drug-induced kidney injuries. Previous MPS have examined single regions of the nephron, but lack simultaneous filtration, reabsorption, and secretion functionality. Here, we developed a partially open MPS that structurally and functionally recapitulated the glomerular filtration barrier, proximal tubular reabsorption, and secretion for seven days. The system introduced a recirculation circuit and an open filtrate output as a source of functional testing. As a proof-of-concept, a tri-culture of immortalized podocytes, umbilical vein endothelial cells, and proximal tubule (PCT) cells were housed in a single MPS: T-junction, glomerulus housing unit, and PCT chip. The MPS successfully retained blood serum protein, reabsorbed glucose, secreted creatinine, and expressed cell-type specific proteins (VE-cadherin, nephrin, and ZO-1). To simulate drug-induced kidney injuries, the system was perfused with cisplatin and adriamycin, and then tested using serum albumin filtration, glucose clearance, and lactate dehydrogenase release. The glomerulus and PCT MPS demonstrated a complex, dynamic microenvironment and recreated some in vivo-like functions in basal and drug-induced conditions, offering a novel prototype for preclinical testing.

19 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
SZStephanie Zhang
Stephanie Zhang
GMGretchen Mahler
Gretchen Mahler
Kidney microphysiological systems (MPS) serve as potentially valuable preclinical instruments in probing mechanisms of renal clearance and osmoregulation. Current kidney MPS models target regions of the nephron, such as the glomerulus and proximal tubule (PCT), but fail to incorporate multiple filtration and absorption interfaces. Here, we describe a novel, partially open glomerulus and PCT microdevice that integrates filtration and absorption in a single MPS. The system equalizes pressure on each side of the PCT that operates with one side “closed” by recirculating into the bloodstream, and the other “opened” by exiting as primary filtrate. This design precisely controls the internal fluid dynamics and prevents loss of all fluid to the open side. Through this feature, an in vitro human glomerulus and proximal tubule MPS was constructed to filter human serum albumin and reabsorb glucose for seven days of operation. For proof-of-concept experiments, three human-derived cell types—conditionally immortalized human podocytes (CIHP-1), human umbilical vein endothelial cells (HUVECs), and human proximal tubule cells (HK-2)—were adapted into a common serum-free medium prior to being seeded into the three-component MPS (T-junction splitter, glomerular housing unit, and parallel proximal tubule barrier model). This system was optimized geometrically (tubing length, tubing internal diameter, and inlet flow rate) using in silico computational modeling. The prototype tri-culture MPS successfully filtered blood serum protein and generated albumin filtration in a physiologically realistic manner, while the device cultured only with proximal tubule cells did not. This glomerulus and proximal convoluted tubule MPS is a potential prototype for the human kidney used in both human-relevant testing and examining pharmacokinetic interactions.

31 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
JPJuan S. Peña
Juan S. Peña
DRDenise A Robles
Denise A Robles
SZStephanie Zhang
Stephanie Zhang
MVMaribel Vazquez
Maribel Vazquez
Neurodegenerative disorders affect millions of adults worldwide. Neuroglia have become recent therapeutic targets due to their reparative abilities in the recycling of exogenous neurotoxins and production of endogenous growth factors for proper functioning of the adult nervous system (NS). Since neuroglia respond effectively to stimuli within in vivo environments on the micron scale, adult glial physiology has remarkable synergy with microscale systems. While clinical studies have begun to explore the reparative action of Müller glia (MG) of the visual system and Schwann Cells (ShC) of the peripheral NS after neural injury, few platforms enable the study of intrinsic neuroglia responses to changes in the local microenvironment. This project developed a low-cost, benchtop-friendly microfluidic system called the glia line system, or gLL, to advance the cellular study needed for emerging glial-based therapies. The gLL was fabricated using elastomeric kits coupled with a metal mold milled via conventional computer numerical controlled (CNC) machines. Experiments used the gLL to measure the viability, adhesion, proliferation, and migration of MG and ShC within scales similar to their respective in vivo microenvironments. Results illustrate differences in neuroglia adhesion patterns and chemotactic behavior significant to advances in regenerative medicine using implants and biomaterials, as well as cell transplantation techniques. Data showed highest survival and proliferation of MG and ShC upon laminin and illustrated a four-fold and two-fold increase of MG migration to dosage-dependent signaling from vascular endothelial growth factor (VEGF) and epidermal growth factor (EGF), respectively, as well as a 20-fold increase of ShC migration toward exogenous brain-derived neurotrophic factor (BDNF), compared to media control. The ability to quantify these biological parameters within the gLL offers an effective and reliable alternative to photolithography study neuroglia in a local environment ranging from the tens to hundreds of microns, using a low-cost and easily fabricated system.