The development of nanomedicines for the treatment of neurodegenerative disorders demands innovative nanoarchitectures for combined loading of multiple neuroprotective compounds. We report dual-drug loaded monoolein-based liquid crystalline architectures designed for the encapsulation of a therapeutic protein and a small molecule antioxidant. Catalase (CAT) is chosen as a metalloprotein, which provides enzymatic defense against oxidative stress caused by reactive oxygen species (ROS) such as hydrogen peroxide (H2O2). Curcumin (CU), solubilized in fish oil, is co-encapsulated as a chosen drug with multiple therapeutic activities, which may favor neuro-regeneration. The prepared self-assembled biomolecular nanoarchitectures are characterized by biological synchrotron small-angle X-ray scattering (BioSAXS) at multiple compositions of the lipid/co-lipid/water phase diagram. Constant fractions of curcumin (an antioxidant) and a PEGylated agent (TPEG1000) are included with regard to the lipid fraction. Stable cubosome architectures are obtained for several ratios of the lipid ingredients monoolein (MO) and fish oil (FO). The impact of catalase on the structural organization of the cubosome nanocarriers is revealed by the variations of the cubic lattice parameters deduced by BioSAXS. The outcome of the cellular uptake of the dual drug-loaded nanocarriers is assessed by performing a bioassay of catalase peroxidatic activity in lysates of nanoparticle-treated differentiated SH-SY5Y human cells. The obtained results reveal the neuroprotective potential of the in vitro studied cubosomes in terms of enhanced peroxidatic activity of the catalase enzyme, which enables the inhibition of H2O2 accumulation in degenerating neuronal cells.
13 October 2020 in Journal of Applied Crystallography
Electron crystallography of sub-micrometre-sized 3D protein crystals has emerged recently as a valuable field of structural biology.In mesocrystallization methods, utilizing lipidic mesophases, particularly lipidic cubic phases (LCPs), can produce high-quality 3D crystals of membrane proteins (MPs). A major step towards realizing 3D electron crystallography of MP crystals, grownin meso, is to demonstrate electron diffraction from such crystals. The first task is to remove the viscous and sticky lipidic matrix that surrounds the crystals without damaging the crystals. Additionally, the crystals have to be thin enough to let electrons traverse them without significant multiple scattering. In the present work, the concept that focused ion beam milling at cryogenic temperatures (cryo-FIB milling) can be used to remove excess host lipidic mesophase matrix is experimentally verified, and then the crystals are thinned to a thickness suitable for electron diffraction. In this study, bacteriorhodopsin (BR) crystals grown in a lipidic cubic mesophase of monoolein were used as a model system. LCP from a part of a hexagon-shaped plate-like BR crystal (∼10 µm in thickness and ∼70 µm in the longest dimension), which was flash-frozen in liquid nitrogen, was milled away with a gallium FIB under cryogenic conditions, and a part of the crystal itself was thinned into a ∼210 nm-thick lamella with the ion beam. The frozen sample was then transferred into an electron cryo-microscope, and a nanovolume of ∼1400 × 1400 × 210 nm of the BR lamella was exposed to 200 kV electrons at a fluence of ∼0.06 e Å−2. The resulting electron diffraction peaks were detected beyond 2.7 Å resolution (with an average peak height to background ratio of >2) by a CMOS-based Ceta 16M camera. The results demonstrate that cryo-FIB milling produces high-quality lamellae from crystals grown in lipidic mesophases and pave the way for 3D electron crystallography on crystals grown or embedded in highly viscous media.
The realization of compact X-ray sources is one of the most intriguing applications of laser-plasma based electron acceleration. These sources based on the oscillation of short micron-sized bunches of relativistic electrons provide femtosecond X-ray pulses that are collimated, bright, and partially coherent. The state-of-the-art laser plasma X-ray sources can provide photon flux of over 1011 photons/shot. The photon flux can further be enhanced with the availability of high repetition rate, high-power lasers, providing capacities complementary to the large scale facilities such as synchrotrons and X-ray free-electron lasers. Even though the optimization of such sources has been underway for the last two decades, their applications in material and biological sciences are still emerging, which entail the necessity of a user-oriented X-ray beamlines. Based on this concept, a high-power-laser-based user-oriented X-ray source is being developed at ELI Beamlines. This article reports on the ELI Gammatron beamline and presents an overview of the research accessible with the ultrashort hard X-ray pulses at the ELI Gammatron beamline.
Hemoglobin is an oxygen-transport protein in red blood cells that interacts with multiple ligands, e.g., oxygen, carbon dioxide, carbon monoxide, and nitric oxide. Genetic variations in hemoglobin chains, such as those underlying sickle cell disease and thalassemias, present substantial clinical challenges. Here, we review the progress in research, including the use of allosteric modulators, pharmacological chaperones, and antioxidant treatments, which has begun to improve hemoglobin stability and oxygen affinity. According to UniProt (as of 7 August 2024), 819 variants of the α-hemoglobin subunit and 771 variants of the β-hemoglobin subunit have been documented, with over 116 classified as unstable. These data demonstrate the urgent need to develop variant-specific stabilizing options. Beyond small-molecule drugs/binders, novel protein-based strategies—such as engineered hemoglobin-binding proteins (including falcilysin, llama-derived nanobodies, and α-hemoglobin-stabilizing proteins)—offer promising new options. As our understanding of hemoglobin’s structural and functional diversity grows, so does the potential for genotype-driven approaches. Continued research into hemoglobin stabilization and ligand-binding modification may yield more precise, effective treatments and pave the way toward effective strategies for hemoglobinopathies.
Crystallography has long been the unrivaled method that can provide the atomistic structural models of macromolecules, using either X-rays or electrons as probes. The methodology has gone through several revolutionary periods, driven by the development of new sources, detectors, and other instrumentation. Novel sources of both X-ray and electrons are constantly emerging. The increase in brightness of these sources, complemented by the advanced detection techniques, has relaxed the traditionally strict need for large, high quality, crystals. Recent reports suggest high-quality diffraction datasets from crystals as small as a few hundreds of nanometers can be routinely obtained. This has resulted in the genesis of a new field of macromolecular nanocrystal crystallography. Here we will make a brief comparative review of this growing field focusing on the use of X-rays and electrons sources.
26 October 2020 in Journal of Synchrotron Radiation
A new modification of a table-top laser-driven water-jet plasma X-ray source has been successfully implemented and commissioned at the Extreme Light Infrastructure (ELI) Beamlines user facility. In order to preserve the broadband nature of the source for spectroscopic experiments, a polycapillary lens was initially chosen as the focusing element. Generally, polycapillary X-ray optics have a narrow photon acceptance angle and small field of view, making alignment complicated and time-consuming. This contribution demonstrates a straightforward, reliable and reproducible procedure for aligning polycapillary focusing optics with broadband X-rays. The method involves a pre-alignment step where two X-ray slits are mounted orthogonally on opposite sides of a 3D-printed cylindrical polycapillary holder. This helps to precisely determine the optical axis of the X-ray beam. Subsequent mounting of the polycapillary in the pre-aligned holder with the slits removed allowed for immediate transmission of the X-ray photons through the optics and has provided a good starting point for fine alignment.